The MLC tongue-and-groove effect on IMRT dose distributions

被引:91
|
作者
Deng, J [1 ]
Pawlicki, T [1 ]
Chen, Y [1 ]
Li, JS [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 04期
关键词
D O I
10.1088/0031-9155/46/4/310
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles (greater than or equal to5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan (greater than or equal to5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (<5) will vary depending on the number of fields in a plan (coplanar or non-coplanar), the MLC leaf sequences and the patient setup uncertainty, and may be significant (>5% of maximum dose) in some cases, especially when the patient setup uncertainty is small (less than or equal to2 mm).
引用
收藏
页码:1039 / 1060
页数:22
相关论文
共 50 条
  • [21] A SIMPLE TONGUE AND GROOVE EFFECT ESTIMATOR FOR IMRT QA
    Williams, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S210 - S210
  • [22] Optimal leaf sequencing with elimination of tongue-and-groove underdosage
    Kamath, S
    Sahni, S
    Palta, J
    Ranka, S
    Li, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (03): : N7 - N19
  • [23] 'Tongue-and-groove' effect in intensity modulated radiotherapy with static multileaf collimator fields
    Que, W
    Kung, J
    Dai, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (03): : 399 - 405
  • [24] Accounting for the tongue-and-groove effect using a robust direct aperture optimization approach
    Salari, Ehsan
    Men, Chunhua
    Romeijn, H. Edwin
    MEDICAL PHYSICS, 2011, 38 (03) : 1266 - 1279
  • [25] Impact of MLC Width On IMRT Planned Dose Distributions in the Skull Base
    Estall, V.
    Jena, R.
    Burnet, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] A new method for modelling the tongue-and-groove in treatment planning systems
    Hernandez, V.
    Vera-Sanchez, J. A.
    Vieillevigne, L.
    Khamphan, C.
    Saez, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S43 - S44
  • [27] Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects
    vanSantvoort, JPC
    Heijmen, BJM
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (10): : 2091 - 2105
  • [28] Tongue and groove effect in direct aperture optimization IMRT plans
    Earl, M.
    Cao, D.
    Shepard, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2145 - 2145
  • [29] Effects of MLC setting on dose distributions and on multileaf collimator parameters for treatments with IMRT
    Chauvet, I
    Petitfils, A
    Brunet, Y
    Lembrez, R
    Lehobey, C
    Kristner, JY
    Zefkili, S
    Gaboriaud, G
    Mazal, A
    Rosenwald, JC
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S36 - S37
  • [30] A new method for modelling the tongue-and-groove in treatment planning systems
    Hernandez, Victor
    Antonio Vera-Sanchez, Juan
    Vieillevigne, Laure
    Khamphan, Catherine
    Saez, Jordi
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (24):