Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement

被引:80
|
作者
Neumann, FJ
Desmet, W
Grube, E
Brachmann, J
Presbitero, P
Rubartelli, P
Mügge, A
Di Pede, F
Füllgraf, D
Aengevaeren, W
Spedicato, L
Popma, JJ
机构
[1] Herz Zentrum Bad Krozingen, D-79189 Bad Krozingen, Germany
[2] Katholieke Univ Leuven Hosp, Dept Cardiol, Louvain, Belgium
[3] Krankenhaus Siegburg GmbH, Herzzentrum, Siegburg, Germany
[4] Klinikum Coburg, Coburg, Germany
[5] Ist Clin Humanitas, Rozzano, Italy
[6] Osped San Martino Genova, Genoa, Italy
[7] Ruhr Univ Bochum, St Josef Hosp, D-4630 Bochum, Germany
[8] Osped Civile Mestre, Venice, Italy
[9] Klinikum Ludenscheid, Ludenscheid, Germany
[10] Univ Med Ctr St Radboud, Nijmegen, Netherlands
[11] Osped S Maria Misericordia, Udine, Italy
[12] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
restenosis; sirolimus; stents;
D O I
10.1161/01.CIR.0000162467.53001.6B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. Methods and Results - The study was designed as a prospective multicenter registry. We included 162 patients with in-stent restenosis of a native coronary artery who had a clinical indication for repeat intervention. Patients were scheduled for follow-up angiography at 6 months. The primary end point was in-lesion late loss. Follow-up angiography was performed in 155 patients. We obtained an in-lesion late loss of 0.08 +/- 0.49 mm and a binary restenosis rate of 9.7% (15/155), which prompted reintervention in 7.4% (12/162) at 9 months. The 9-month rate of death was 1.2% (2/162) and that of nonfatal myocardial infarction was 1.2% (2/162). Conclusions - Sirolimus-eluting stents were highly efficacious and safe in the treatment of in-stent restenosis. Our study provides rationale for the use of sirolimus-eluting stents in the treatment of in-stent restenosis.
引用
收藏
页码:2107 / 2111
页数:5
相关论文
共 50 条
  • [1] Treatment of coronary in-stent restenosis with sirolimus-eluting stents
    Urban, P
    Guagliumi, G
    Gershlick, A
    Lotan, C
    Sousa, E
    Wijns, W
    Seth, A
    EUROPEAN HEART JOURNAL, 2004, 25 : 671 - 671
  • [2] Everolimus versus sirolimus-eluting stents for the treatment of sirolimus-eluting stent restenosis
    Yan, Rong-Qiang
    Gao, Li-Jian
    Chen, Ji-Lin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 165 (03) : 568 - 569
  • [3] Long-term effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement: 3-year results of the TROPICAL study
    Neumann, Franz-Josef
    Desmet, Walter J.
    Grube, Eberhard
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 177M - 178M
  • [4] Long-term effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement: 2-year results of the TROPICAL study
    Neumann, F. J.
    Desmet, W. J.
    Grube, E.
    EUROPEAN HEART JOURNAL, 2005, 26 : 708 - 709
  • [5] Late Restenosis of Sirolimus-eluting Stent in the Treatment of In-stent Restenosis of Sirolimus-eluting Stent
    Shibayama, Kentaro
    Kadota, Kazushige
    Tsujimoto, Yuki
    Saito, Naoki
    Miyamoto, Masakazu
    Otsuru, Suguru
    Okamoto, Yoji
    Imai, Masao
    Tasaka, Hiroshi
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Habara, Seiji
    Tanaka, Hiroyuki
    Maruo, Takeshi
    Hirono, Akitoshi
    Nishibori, Yosiharu
    Hosogi, Shingo
    Fuku, Yasushi
    Oka, Naoki
    Katoh, Hurumi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Goto, Tsuyoshi
    Inoue, Katsumi
    Mitsudo, Kazuaki
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 161D - 161D
  • [6] Recurrent Restenosis After Reimplantation With Sirolimus-eluting Stent for Restenosis After Sirolimus-eluting Stent Implantation
    Miyamoto, Masakazu
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Gotoh, Tsuyoshi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Fuku, Yasushi
    Hosogi, Shingo
    Tanaka, Hiroyuki
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    Ohtsuru, Suguru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A10 - A10
  • [7] Comparison of Sirolimus versus Paclitaxel-eluting Stents for Treatment of Sirolimus-Eluting Stent Restenosis
    Habara, Seiji
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Kato, Harumi
    Oka, Naoki
    Fuku, Yasushi
    Hosogi, Shingo
    Hirono, Akitoshi
    Kawakami, Toru
    Maruo, Takeshi
    Tanaka, Hiroyuki
    Hasegawa, Daiji
    Imai, Masao
    Tasaka, Hiroshi
    Yamada, Chinatsu
    Okamoto, Yoji
    Otsuru, Suguru
    Miyamoto, Masakazu
    Saito, Naoki
    Shibayama, Kentaro
    Tsujimoto, Yuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A39 - A39
  • [8] Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents
    Kim, Jung-Sun
    Lee, Seung-Yul
    Lee, Jung Myung
    Yoon, Young Won
    Ahn, Chul-Min
    Kim, Myung-Hyun
    Min, Pil-Ki
    Ko, Young-Guk
    Hong, Bum-Kee
    Choi, Donghoon
    Kwon, Hyuck Moon
    Jang, Yangsoo
    Shim, Won-Heum
    CORONARY ARTERY DISEASE, 2009, 20 (01) : 59 - 63
  • [9] Treatment of renal artery in-stent restenosis with sirolimus-eluting stents
    Kiernan, Thomas J.
    Yan, Bryan P.
    Eisenberg, Jonathan D.
    Ruggiero, Nicholas J.
    Gupta, Vishal
    Drachman, Douglas
    Schainfeld, Robert M.
    Jaff, Michael R.
    Rosenfield, Kenneth
    Garasic, Joseph
    VASCULAR MEDICINE, 2010, 15 (01) : 3 - 7
  • [10] Sirolimus-Eluting Stents: Safe and effective in the treatment of in-stent restenosis
    Neumann, FJ
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (02) : 163 - 164