Development and Validation of the First Smart TV-Based Visual Acuity Test: A Prospective Study

被引:2
|
作者
Labiris, Georgios [1 ]
Delibasis, Konstantinos [2 ]
Panagiotopoulou, Eirini-Kanella [1 ]
Pigadas, Vassilis [2 ]
Bakirtzis, Minas [1 ]
Panagis, Christos [1 ]
Dardabounis, Doukas [1 ]
Ntonti, Panagiota [1 ]
机构
[1] Univ Hosp Alexandroupolis, Dept Ophthalmol, Dragana 68100, Alexandroupolis, Greece
[2] Univ Thessaly, Dept Comp Sci & Biomed Informat, Lamia 35100, Greece
关键词
visual acuity test; smart TV; smartphone; home; validation; telemedicine; QUALITY-OF-LIFE; DIABETIC-RETINOPATHY;
D O I
10.3390/healthcare10112117
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
(1) Background: While smartphones are among the primary devices used in telemedical applications, smart TV healthcare apps are not prevalent despite smart TVs' penetrance in home settings. The present study's objective was to develop and validate the first smart TV-based visual acuity (VA) test (Democritus Digital Visual Acuity Test (DDiVAT)) that allows a reliable VA self-assessment. (2) Methods: This is a prospective validation study. DDiVAT introduces several advanced features for reliable VA self-testing; among them: automatic calibration, voice recognition, voice guidance, automatic calculation of VA indexes, and a smart TV-based messaging system. Normal and low vision participants were included in the validation. DDiVAT VA results (VA(DDiVAT)) were compared against the ones from: (a) the gold-standard conventional ETDRS (VA(ETDRS)), and, (b) an independent ophthalmologist who monitored the self-examination testing (VA(RES)). Comparisons were performed by noninferiority test (set at 2.5-letters) and intraclass correlation coefficients (ICCs). DDiVAT's test-retest reliability was assessed within a 15-day time-window. (3) Results: A total of 300 participants (185 and 115 with normal and low vision, respectively) responded to ETDRS and DDiVAT. Mean difference in letters was -0.05 for VA(ETDRS)-VA(RES), 0.62 for VA(RES)-VA(DDiVAT), and 0.67 for VA(ETDRS)-VA(DDiVAT), significantly lower than the 2.5 letter noninferiority margin. ICCs indicated an excellent level of agreement, collectively and for each group (0.922-0.996). All displayed letters in DDiVAT presented a similar difficulty. The overall accuracy of the voice recognition service was 96.01%. ICC for VA(DDiVAT) test-retest was 0.957. (4) Conclusions: The proposed DDiVAT presented non-significant VA differences with the ETDRS, suggesting that it can be used for accurate VA self-assessment in telemedical settings, both for normal and low-vision patients.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Ophthalmological follow up of preterm infants:: a population based, prospective study of visual acuity and strabismus
    Holmström, G
    el Azazi, M
    Kugelberg, U
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (02) : 143 - 150
  • [32] DEVELOPMENT OF VISUAL-ACUITY IN KITTENS - A COMPARISON BETWEEN JUMPING STAND AND TELLER ACUITY CARD TEST
    KATZ, B
    SIRETEANU, R
    CLINICAL VISION SCIENCES, 1992, 7 (03): : 219 - 224
  • [33] Development and validation of a visual acuity chart for Australian Aborigines and Torres Strait Islanders
    Wildsoet, CF
    Wood, JM
    Hassan, S
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (11) : 806 - 812
  • [34] Development and validation of the fi rst Canadian Aboriginal syllabics visual acuity chart
    Bhambra, Nishaant
    Dhillon, Jobanpreet
    Rahman, Sidrat
    El-Hadad, Christian
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (02): : e117 - e123
  • [35] Development and first validation of the COPD Assessment Test
    Jones, P. W.
    Harding, G.
    Berry, P.
    Wiklund, I.
    Chen, W-H.
    Leidy, N. Kline
    EUROPEAN RESPIRATORY JOURNAL, 2009, 34 (03) : 648 - 654
  • [36] Agreement between a mobile applet-based visual acuity self-test program and the conventional method for distance and near visual acuity test
    Xian, Yiyong
    Ye, Yuhao
    Liu, Fang
    Zhou, Xingtao
    Zhao, Jing
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (02): : 112 - 121
  • [37] Effects of low visual acuity on neuropsychological test scores: A simulation study
    de Haan, Gera A.
    Tucha, Oliver
    Heutink, Joost
    CLINICAL NEUROPSYCHOLOGIST, 2020, 34 (01) : 140 - 157
  • [38] Urban greenspace and visual acuity in schoolchildren: a large prospective cohort study in China
    Bao, Wen -Wen
    Zhao, Yu
    Dadvand, Payam
    Jiang, Nan
    Chen, Gongbo
    Yang, Boyi
    Huang, Wenzhong
    Xiao, Xiang
    Liang, Jinghong
    Chen, Yican
    Huang, Shan
    Pu, Xueya
    Huang, Shaoyi
    Lin, Haotian
    Guo, Yuming
    Dong, Guanghui
    Chen, Yajun
    ENVIRONMENT INTERNATIONAL, 2024, 184
  • [39] Of Social Television Comes Home: A Field Study of Communication Choices and Practices in TV-Based Text and Voice Chat
    Huang, Elaine M.
    Harboe, Gunnar
    Tullio, Joe
    Novak, Ashley
    Massey, Noel
    Metcalf, Crysta J.
    Romano, Guy
    CHI2009: PROCEEDINGS OF THE 27TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, VOLS 1-4, 2009, : 585 - 594
  • [40] Development and first validation of the COugh Assessment Test (COAT)
    Jang, Seung Hun
    Kim, Joo-Hee
    Koo, Hyeon-Kyoung
    Jeong, Ina
    Park, So Young
    Kim, Dong-Gyu
    Rhee, Chin Kook
    Kim, Yee Hyung
    Kim, Sung-Kyoung
    Choi, Eun Young
    Moon, Ji-Yong
    Shin, Jong-Wook
    Kim, Jin Woo
    Min, Kyung Hoon
    Kim, Deog Kyeom
    Lee, Hyun
    Kim, Je Hyeong
    Yoon, Hyoung Kyu
    Kim, Hui Jung
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50