Purpose: The purpose of this study was to compare the success of hydroxyapatite (HA)-coated and machined titanium (Ti) implants in a 5-year randomized, controlled clinical trial conducted at 2 centers. Materials and Methods: Each of 120 edentulous patients received HA-coated threaded, HA-coated cylindric, and machined Ti threaded implants in a randomized design using 5 or 6 implants. Digital radiographs allowed for yearly measurements of bone loss. Calibrated clinicians also measured mobility, Gingival index, Plaque Index, probing depth, and recession. A Kaplan-Meier analysis was used to compare the proportion of ailing implants (defined as less than 2 mm of alveolar bone loss over 5 years) for each type of implant design. The criteria employed to assess implant outcome included the need for successful implants to lose less than 2 mm of bone support over the 5 years following placement of the prosthesis. Results: This analysis revealed that 95.2% of machined Ti threaded implants and 97.92% of HA-coated threaded implants were successful, while 99.0% of HA-coated cylindric implants experienced less than 2 mm of bone loss (P < .06). Discussion: All types of implants placed in this study had success rates above 95%. Conclusion: Over 5 years, the success rate tended to favor HA-coated implants.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 50 条
  • [41] Hydroxyapatite coated dental implants by laser
    Jelinek, M
    Dostalova, T
    Himmlova, L
    Grivas, C
    LASERS IN MEDICINE AND DENTISTRY: DIAGNOSTICS AND TREATMENT, 1996, 2887 : 120 - 128
  • [42] Loaded hydroxylapatite-coated implants and uncoated titanium-threaded implants in distracted dog alveolar ridges
    Block, MS
    Gardiner, D
    Almerico, B
    Neal, C
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 89 (06): : 676 - 685
  • [43] The effect of adding an equine bone matrix protein lyophilisate on fixation and osseointegration of HA-coated Ti implants
    Baas, Jorgen
    Jakobsen, Thomas
    Elmengaard, Brian
    Bechtold, Joan E.
    Soballe, Kjeld
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (01) : 188 - 194
  • [44] ANCHORAGE OF TIO2-BLASTED, HA-COATED, AND MACHINED IMPLANTS - AN EXPERIMENTAL-STUDY WITH RABBITS
    GOTFREDSEN, K
    WENNERBERG, A
    JOHANSSON, C
    SKOVGAARD, LT
    HJORTINGHANSEN, E
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (10): : 1223 - 1231
  • [45] Evaluation in vitro and in vivo of biomimetic hydroxyapatite coated on titanium dental implants
    Rigo, ECS
    Boschi, AO
    Yoshimoto, M
    Allegrini, S
    Konig, B
    Carbonari, MJ
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2004, 24 (05): : 647 - 651
  • [46] HISTOMORPHOMETRIC ANALYSIS OF HA VERSUS NON-HA COATED IMPLANTS IN MINIPIGS
    CHAMBERS, K
    GERARD, DA
    GOTCHER, J
    CHASE, DC
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 137 - 137
  • [47] Uncemented HA-coated implant is the optimum fixation for TKA in the young patient
    Nilsson, Kjell G.
    Henricson, Anders
    Norgren, Bo
    Dalen, Tore
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) : 129 - 138
  • [48] Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty
    Duffy, P
    Sher, JL
    Partington, PF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01): : 34 - 38
  • [49] HISTOLOGICAL ANALYSIS OF 10 HA-COATED HIP PROSTHESES IMPLANTED IN HUMANS
    FRAYSSINET, P
    HARDY, D
    CONTE, P
    DELINCE, P
    GUILHEM, A
    BONEL, G
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1993, 79 (03): : 177 - 184
  • [50] THE EFFECT OF DRY HEAT AUTOCLAVING ON HA COATED IMPLANTS
    MEILLEUR, KM
    ZABLOTSKY, MH
    LAYMAN, DL
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 370 - 370