Vacuum-formed matrix as a guide for the fabrication of craniofacial implant tissue bar-retained auricular prostheses

被引:9
|
作者
Cheng, AC [1 ]
Morrison, D [1 ]
Cho, RS [1 ]
Archibald, D [1 ]
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Dept Dent, Toronto, ON M5G 2M9, Canada
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1998年 / 79卷 / 06期
关键词
D O I
10.1016/S0022-3913(98)70081-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Craniofacial implant-retained auricular prostheses usually require a tissue bar and/or retentive elements in addition to the prosthetic ear. Complete coverage of the tissue bar and retentive elements in a given bulk of prosthetic material is sometimes difficult to achieve, but it is crucial to ensure that all the prosthetic components are kept within the contour of the auricular prosthesis to maintain esthetics and form. This article describes a method for fabrication of auricular prostheses with all the elements predictably confined within the anatomic contour of the prostheses.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 13 条
  • [1] Fabrication of a surgical template for implant/bar-retained mandibular overdentures
    Fakhry, A
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (04) : 401 - 407
  • [2] Stress Analysis of two craniofacial implants in implant retained auricular prostheses
    Abbas, Ahmed Abdulrahman
    Chanthasopeephan, Teeranoot
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 4816 - 4819
  • [3] Simple Method of Record Base Fabrication for a Bar-Retained Implant Overdenture
    Oh, Won-suk
    Park, Ju-mi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08): : 638 - 640
  • [4] A SURGICAL GUIDE FOR CRANIOFACIAL IMPLANT PLACEMENT FOR AN IMPLANT-RETAINED AURICULAR PROSTHESIS
    Ozcelik, Tuncer Burak
    Tanner, Paul Benjamin
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (04): : 253 - 255
  • [5] Vacuum-formed matrix as a guide for the fabrication of multiple direct patterns for cast posts and cores
    Bluche, LR
    Bluche, PF
    Morgano, SM
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (03): : 326 - 327
  • [6] Peri-implant soft tissue maintenance in patients with craniofacial implant retained prostheses
    Allen, PF
    Watson, G
    Stassen, L
    McMillan, AS
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 29 (02) : 99 - 103
  • [7] USE OF A THERMOPLASTIC VACUUM-FORMED MATRIX FOR SECURE ENGAGEMENT OF AN IMPLANT SURGICAL TEMPLATE
    Oh, Won-suk
    Saglik, Berna
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (04): : 326 - 327
  • [8] Fabrication of a Fractured Mandibular Bar-Retained Implant Overdenture Without Implant-Level Impression Making: A Clinical Report
    Uludag, Bulent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08): : 622 - 625
  • [9] Magnetic retention and bar-clip attachment for implant-retained auricular prostheses: A comparative analysis
    de Sousa, Andrea Alves
    Camara Mattos, Beatriz Silva
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (03) : 233 - 236
  • [10] Vacuum-formed tooth position record as an index for the fabrication of an endosseous implant-supported prosthesis
    Cheng, AC
    Wee, AG
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (05): : 546 - 548