Simple Method of Record Base Fabrication for a Bar-Retained Implant Overdenture

被引:0
|
作者
Oh, Won-suk [1 ]
Park, Ju-mi [2 ]
机构
[1] Univ Michigan, Sch Dent, Dept Biol & Mat Sci, Ann Arbor, MI 48109 USA
[2] Chonbuk Natl Univ, Sch Dent, Dept Prosthodont, Jeonju 561756, Jeonbuk, South Korea
关键词
Record base; cast mounting; implant connecting bar; implant-retained overdenture; STABILITY;
D O I
10.1111/j.1532-849X.2012.00893.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A record base should be stable and accurately transferable from the cast to the mouth. This article describes a simple and practical method of fabricating a record base for mounting a master cast used to fabricate an implant connecting bar for an implant-retained overdenture.
引用
收藏
页码:638 / 640
页数:3
相关论文
共 42 条
  • [1] ATTACHMENT OF CLIPS IN A BAR-RETAINED MAXILLARY IMPLANT OVERDENTURE: A CLINICAL REPORT
    Slot, Wim
    Raghoebar, Gerry M.
    van Dijk, Gerrit
    Meijer, Henny J. A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06): : 353 - 357
  • [2] Simplified procedure for replacement of retentive clips in a bar-retained implant overdenture
    Welsh, G
    Bissell, V
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (05): : 586 - 588
  • [3] Fabrication of a Fractured Mandibular Bar-Retained Implant Overdenture Without Implant-Level Impression Making: A Clinical Report
    Uludag, Bulent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08): : 622 - 625
  • [4] Fabrication of a surgical template for implant/bar-retained mandibular overdentures
    Fakhry, A
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (04) : 401 - 407
  • [5] Vacuum-formed matrix as a guide for the fabrication of craniofacial implant tissue bar-retained auricular prostheses
    Cheng, AC
    Morrison, D
    Cho, RS
    Archibald, D
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (06): : 711 - 714
  • [6] Soft Liner/Clip Attachment for Bar-Retained Implant Overdentures: A Technical Note
    ELsyad, Moustafa Abdou
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 442 - 444
  • [7] Implant-Supported, Bar-Retained Maxillary Overdenture and Mandibular Implant-Supported, Metal-Acrylic Resin, Screw-Retained, Fixed Complete Denture on an Edentulous Patient: Case Report
    Fahmi, Mohammed
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (04) : 335 - 348
  • [8] RADIOGRAPHIC AND SURGICAL GUIDE FABRICATION FOR IMPLANT-RETAINED MANDIBULAR OVERDENTURE
    Wulfman, Claudine
    Hadida, Alain
    Rignon-Bret, Christophe
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (01): : 53 - 57
  • [9] Fabrication of a Maxillary Implant Retained Overdenture Using an Existing Subperiostal Implant: A Clinical Report
    Barrero, Carlos
    Border, Michael B.
    Bencharit, Sompop
    OPEN DENTISTRY JOURNAL, 2011, 5 : 122 - 125
  • [10] A Comparison of Two Soldering Techniques on the Misfit of Bar-Retained Implant-Supported Overdentures
    Alvarez, Angel
    Lafita, Pedro
    de Llanos, Hector
    Gago, Angel
    Brizuela, Aritza
    Ellacuria, Joseba J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (02): : 163 - 170