Improved LVRT/HVRT Capability Of DFIG Wind Turbine Using DVR

被引:1
|
作者
Bouaziz, Fatma [1 ]
Abdelkafi, Achraf [1 ]
Masmoudi, Abdelkarim [1 ]
Krichen, Lotfi [1 ]
机构
[1] Univ Sfax, Natl Engn Sch Sfax, Elect Syst & Renewable Energies Lab LSEER, Sfax, Tunisia
关键词
Doubly fed induction generator; Fault ride-through; Dynamic voltage restorer; POWER; LVRT; ENHANCEMENT;
D O I
10.1109/IC_ASET53395.2022.9765942
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper proposes a method that improved the efficiency of a doubly fed induction generator (DFIG) in the case of network voltage imbalance. In the suggested configuration, a dynamic voltage restorer (DVR) is combined in series to the terminal system allowing compensating two types of fault LVRT/HVRT. The DVR device has the ability to compensate the stator voltage by injecting the appropriate at the stator that leads to keeping the generator terminal voltage at the normal level and improving the fault ride-through (FRT) ability of DFIG. Simulations in MATLAB/Simulink for a DFIG are used to verify the efficiency of the suggested control method on both types of faults.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 50 条
  • [41] Enhancement of LVRT Capability of DFIG-based Wind Turbines by Superconducting Fault Current Limiter
    Zolfi, Pouya
    Tohidi, Sajjad
    Abapour, Mehdi
    26TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE 2018), 2018, : 1032 - 1037
  • [42] Enhancing LVRT Capability of FSIG Wind Turbine Using Current Source UPQC Based on Resistive SFCL
    Moghadasi, Amir
    Islam, Arif
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [43] Virtual Damping Flux-Based LVRT Control for DFIG-Based Wind Turbine
    Zhu, Rongwu
    Chen, Zhe
    Wu, Xiaojie
    Deng, Fujin
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) : 714 - 725
  • [44] Enhancement of LVRT Performance and Alleviation of Power Fluctuation of DFIG Wind Turbine in DC Microgrid by SMES
    Karaipoom, Tanapon
    Ngamroo, Issarachai
    2013 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD), 2013, : 207 - 208
  • [45] Coordinated Reactive Power Control of DFIG to Improve LVRT Characteristics of FSIG in Wind Turbine Generation
    Minh Quan Duong
    Sava, Gabriela Nicoleta
    2017 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND POWER SYSTEMS (SIELMEN), 2017, : 256 - 260
  • [46] Implementation Strategy of Test Facility Based on Auto-Transformer for LVRT/HVRT Evaluation of Large-Scale Wind Turbine
    Kim, Byungki
    Nam, Yang-Hyun
    Ryu, Kyung-Sang
    Kim, Dae-Jin
    ENERGIES, 2023, 16 (10)
  • [47] Coordinated LVRT and HVRT Control Scheme for PMSG-based Wind Farm
    Yuan, Liang
    Meng, Ke
    Huang, Jingjie
    Dong, Zhao Yang
    Zhang, Wang
    2019 29TH AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2019,
  • [48] Advanced Reactive Power Control Strategy for Better LVRT Capability for DFIG-based Wind Farm
    Gatavi, Ehsan
    Hellany, Ali
    Nagrial, Mahmood
    Rizk, Jamal
    2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,
  • [49] A New Control Strategy Based on Reference Values Changing for Enhancing LVRT Capability of DFIG in Wind Farm
    Rafiee, Zahra
    Rafiee, Mansour
    Aghamohammadi, Mohammadreza
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (04): : 1626 - 1637
  • [50] Robust Active Disturbance Rejection Control for LVRT capability enhancement of DFIG-based wind turbines
    Beltran-Pulido, Andres
    Cortes-Romero, John
    Coral-Enriquez, Horacio
    CONTROL ENGINEERING PRACTICE, 2018, 77 : 174 - 189