Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia

被引:11
|
作者
Choi, Jong Bum [1 ]
Kwak, Hyun Jeong [2 ]
Lee, Kyung Cheon [2 ]
Lee, Se Ryeon [3 ]
Lee, Sook Young [3 ]
Kim, Jong Yeop [3 ]
机构
[1] Yonsei Univ, Coll Med, Anesthesia & Pain Res Inst, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Gachon Univ, Gil Med Ctr, Dept Anesthesiol & Pain Med, Inchon, South Korea
[3] Ajou Univ, Sch Med, Dept Anesthesiol & Pain Med, San 5, Suwon 443721, South Korea
关键词
i-gel; Laryngeal mask airway; Remifentanil; TARGET-CONTROLLED INFUSION; SUPRAGLOTTIC AIRWAY; CONFIDENCE-INTERVALS; REQUIREMENTS; INDUCTION; DESIGN; TERMS; TUBE; CUFF;
D O I
10.1007/s00540-015-2133-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Each supraglottic airway requires different anesthetic depth because it has a specific structure and different compressive force in the oropharyngeal cavity. We designed the study to compare the effect-site concentration (Ce) of remifentanil in 50 % of patients (EC50) for successful insertion of the i-gel second-generation supraglottic airway device with that for laryngeal mask airway (LMA) insertion during target-controlled infusion (TCI) of propofol. Forty-one female patients were randomized to the i-gel group (n = 20) or the LMA group (n = 21). Anesthesia was induced with propofol Ce of 5 mu g/ml and the predetermined remifentanil Ce, and the i-gel or LMA was inserted 5 min later. The remifentanil Ce was estimated by modified Dixon's up-and-down method (initial concentration: 3.0 ng/ml, step size: 0.5 ng/ml). The patient's response to device insertion was classified as either "success (no movement)" or "failure (movement)". Using the Dixon's up-and-down method, EC50 of remifentanil Ce for the i-gel (1.58 +/- 0.41 ng/ml) was significantly lower than that for LMA (2.25 +/- 0.55 ng/ml) (p = 0.038). Using isotonic regression, EC50 (83 % CI) of remifentanil in the i-gel group [1.50 (1.37-1.80) ng/ml] was statistically lower than that in the LMA group [2.00 (1.82-2.34) ng/ml]. EC95 (95 % CI) of remifentanil in the i-gel group [2.38 (1.48-2.50) ng/ml] was statistically lower than that in the LMA group [3.35 (2.58-3.48) ng/ml]. We found that EC50 of remifentanil Ce for i-gel insertion (1.58 ng/ml) was significantly lower than that for LMA insertion (2.25 ng/ml) in female patients during propofol TCI without neuromuscular blockade.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [31] EC50 of sevoflurane for classic laryngeal mask airway insertion in children at different time points: A randomized blind trial
    Sethi, Sameer
    Goel, Nitika
    Ghai, Babita
    Sharma, Mantoliya N.
    Ram, Jagat
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2020, 36 (04) : 489 - 493
  • [32] Effects of dexmedetomidine as an adjuvant in thoracic paravertebral block on EC50 of propofol for successful laryngeal mask insertion: a randomized controlled trial
    Guo, Fei
    Chen, Hao
    Cai, Xuejiao
    Ge, Jianlin
    Du, Boxiang
    Song, Jie
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (22)
  • [33] A comparison of the insertion characteristics of the laryngeal tube and the laryngeal mask airway: a study of the ED50 propofol requirements
    Burlacu, CL
    Gaskin, P
    Fernandes, A
    Carey, M
    Briggs, L
    ANAESTHESIA, 2006, 61 (03) : 229 - 233
  • [34] Tongue numbness following laryngeal mask airway Supreme™ and i-gel™ insertion: two case reports
    Rujirojindakul, P.
    Prechawai, C.
    Watanayomnaporn, E.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (09) : 1200 - 1203
  • [35] Topical lignocaine and thiopentone for the insertion of a laryngeal mask airway - A comparison with propofol
    Seavell, CR
    Cook, TM
    Cox, CM
    ANAESTHESIA, 1996, 51 (07) : 699 - 701
  • [36] Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance
    Ari, Dilek Erdogan
    Ar, Arzu Yildirim
    Karip, Ceren Sanli
    Siyahkoc, Incifer
    Arslan, Ahmet Hakan
    Akgun, Fatma Nur
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (05) : 299 - 303
  • [37] Comparison of propofol and sevoflurane for laryngeal mask airway insertion in elderly patients
    Shao, GuiQian
    Zhang, GuoHua
    SOUTHERN MEDICAL JOURNAL, 2007, 100 (04) : 360 - 365
  • [38] Comparison of endotracheal intubation, laryngeal mask airway, and I-gel in children undergoing strabismus surgery
    Allahyari, Elaheh
    Azimi, Ali
    Zarei, Hamed
    Bamdad, Shahram
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2021, 26 (01):
  • [39] Are nurses able to perform blind intubation? Randomized comparison of I-gel and laryngeal mask airway
    Ladny, Jerzy R.
    Bielski, Karol
    Szarpak, Lukasz
    Cieciel, Michal
    Konski, Roman
    Smereka, Jacek
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 786 - 787
  • [40] Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin
    de Lloyd, L.
    Hodzovic, I.
    Voisey, S.
    Wilkes, A. R.
    Latto, I. P.
    ANAESTHESIA, 2010, 65 (01) : 36 - 43