ENERGY EVALUATION OF DROP-IN REPLACEMENTS FOR R134a IN CASCADE CO2/R134a REFRIGERATION UNITS

被引:0
|
作者
Makhnatch, Pavel [1 ]
Mota-Babiloni, Adrian [2 ]
Khodabandeh, Rahmatollah [1 ]
机构
[1] KTH Royal Inst Technol, Dept Energy Technol, Div Appl Thermodynam & Refrigerat, S-10044 Stockholm, Sweden
[2] Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, E-12071 Castellon De La Plana, Spain
关键词
cascade system; CO2; climate change; GWP; HFC substitution; energy assessment; GWP; PERFORMANCE; R404A; ALTERNATIVES; R450A; R448A;
D O I
10.18462/iir.gl.2018.1373
中图分类号
O414.1 [热力学];
学科分类号
摘要
The energy performance of CO2 standard booster systems is limited in countries with high ambient temperatures to replace R404A direct expansion architectures. Therefore, cascade refrigeration systems with CO2 in the low-pressure stage can be considered. Most of the conventional cascade refrigeration systems rely on using R134a, a high global warming potential (GWP) refrigerant, in the high pressure stage. However, R134a needs to be replaced by lower GWP refrigerants to meet the targets of current environmental agreements. This study investigates R450A and R513A refrigerants as drop-in replacements to R134a in R134a/CO2 cascade refrigeration units. The experimental energy performance results suggest that both R450A and R513A can substitute R134a in cascade systems. R513A provides comparable COP and cooling capacity values to R134a, whereas the cooling capacity and COP of R450A are lower than that of the baseline R134a.
引用
下载
收藏
页码:1147 / 1153
页数:7
相关论文
共 50 条
  • [1] Experimental evaluation of a R134a/CO2 cascade refrigeration plant
    Sanz-Kock, Carlos
    Llopis, Rodrigo
    Sanchez, Daniel
    Cabello, Ramon
    Torrella, Enrique
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 41 - 50
  • [2] Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants
    Cabello, R.
    Sanchez, D.
    Llopis, R.
    Catalan, J.
    Nebot-Andres, L.
    Torrella, E.
    APPLIED THERMAL ENGINEERING, 2017, 110 : 972 - 984
  • [3] Energy and exergy analysis of R1234yf as drop-in replacement for R134a in a domestic refrigeration system
    Belman-Flores, J. M.
    Rangel-Hernandez, V. H.
    Uson, S.
    Rubio-Maya, C.
    ENERGY, 2017, 132 : 116 - 125
  • [4] Energy and exergy analyses of R513a as a R134a drop-in replacement in a vapor compression refrigeration system
    Sun, Jian
    Li, Wenhua
    Cui, Borui
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 : 348 - 356
  • [5] Performance comparison between the combined R134a/CO2 heat pump and cascade R134a/CO2 heat pump for space heating
    Song, Yulong
    Li, Dongzhe
    Yang, Dongfang
    Jin, Lei
    Cao, Feng
    Wang, Xiaolin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 592 - 605
  • [6] Experimental study of R450A drop-in performance in an R134a small capacity refrigeration unit
    Makhnatch, Pavel
    Mota-Babiloni, Adrian
    Khodabandeh, Rahmatollah
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 26 - 35
  • [7] Performance Evaluation of Centrifugal Refrigeration Compressor Using R1234yf and R1234ze(E) as Drop-In Replacements for R134a Refrigerant
    Yi, Kexin
    Zhao, Yuanyang
    Liu, Guangbin
    Yang, Qichao
    Yu, Guoxin
    Li, Liansheng
    ENERGIES, 2022, 15 (07)
  • [8] Theoretical and experimental research on the drop-in alternative R32/R134a
    Xi'an Jianzhu Keji Daxue Xuebao, 2 (206-211):
  • [9] Analysis of COP Using Blended R134a and R600a in Refrigeration System as a Replacement to R134a
    Panda N.K.
    Mishra S.K.
    Samal D.K.
    Padhi B.N.
    Journal of The Institution of Engineers (India): Series C, 2024, 105 (03) : 427 - 435
  • [10] Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan, Angel
    Moles, Francisco
    Peris, Bernardo
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 259 - 265