Surveillance of infectious complications associated with central venous access devices in children with haemophilia

被引:40
|
作者
Tarantino, MD
Lail, A
Donfield, SM
Lynn, H
Peddle, L
Hunsberger, S
Shapiro, AD
机构
[1] Univ Illinois, Comprehens Bleeding Disorders Ctr, Coll Med, Peoria, IL 61614 USA
[2] Rho Inc, Chapel Hill, NC USA
[3] Indiana Hemophilia & Thrombosis Ctr, Indianapolis, IN USA
关键词
catheter-related infection; central venous catheter; haemophilia; inhibitor;
D O I
10.1046/j.1365-2516.2003.00793.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To analyse the risk factors for infection associated with central venous access device (CVAD) use in children with haemophilia. Methods: Risk factors for CVAD infection among patients with congenital haemophilia who had had a CVAD implanted at a single institution were evaluated utilizing the following variables: age at CVAD placement, age at end of study, number of days with a CVAD, percentage of lifetime with a CVAD, and history of inhibitor. Results: Fifty-nine patients had a total of 97 936 (median 1768 days per patient) CVAD days in the study period. The median age at CVAD placement was 2.7 years (range 0-14.0). Twenty-six (44%) patients reported CVAD infections during the study period from January 1993 to October 2000. Twenty-four patients had their CVAD replaced, 17 (71%) of whom reported having infections and seven (29%) of whom had a history of inhibitor. The strongest predictor for having any infections was inhibitor status (P = 0.16), although none of the risk factors had statistically significant effects. Among the 26 patients reporting infections, 42% had more than one CVAD-related infection. Seven patients had multiple infections involving the same organism. The mean rate of infection was 0.45 per 1000 catheter days, with a 95% confidence interval of 0.33-0.60. Those with a history of inhibitor had an infection rate of 0.66 compared with 0.38 per 1000 catheter days (P = 0.09) for those without a history of inhibitor. Patients who were older ( greater than the median age of 2.7) at CVAD placement had a lower rate of infection (0.29 vs. 0.65, P < 0.01) compared with those ≤2.7 years. Adjustment for inhibitor status had little impact on these results. For the group as a whole, the median time to first infection was 1977 days from CVAD placement. Patients who were older at CVAD placement or study exit had lower relative hazards of infection (P = 0.05 and P = 0.09 respectively), while those who had inhibitors had a higher but not statistically significant relative hazard of 1.88 (P = 0.13). Conclusions: These data reveal that while considerable numbers of patients develop CVAD-related infection, the interval between catheter placement and infection can be quite long. In addition, the earlier in life a CVAD is placed, the higher the risk of infectious complications, as evidenced by the tendency towards a higher infection rate. Measures to prevent CVAD-related infection might be focused on very young patients who appear to be at higher risk.
引用
下载
收藏
页码:588 / 592
页数:5
相关论文
共 50 条
  • [31] Infectious complications of implantable venous access devices in patients with sickle cell disease
    Wagner, SC
    Eschelman, DJ
    Gonsalves, CF
    Bonn, J
    Sullivan, KL
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (04) : 375 - 378
  • [32] Complications of central venous access devices: outcome analysis of 2359 implantations
    Stein, M
    Wagner, RH
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2005, 130 (18) : 1129 - 1132
  • [33] Thrombotic complications of implanted central venous access devices: prospective evaluation
    Labourey, JL
    Lacroix, P
    Genet, D
    Gobeaux, F
    Martin, J
    Venat-Bouvet, L
    Lavau-Denes, S
    Maubon, A
    Tubiana-Mathieu, N
    BULLETIN DU CANCER, 2004, 91 (05) : 431 - 436
  • [34] Central venous access devices for paediatric patients with haemophilia: a single-institution experience
    Titapiwatanakun, R.
    Moir, C.
    Pruthi, R. K.
    Stavlo, P. L.
    Schmidt, K. A.
    Rodriguez, V.
    HAEMOPHILIA, 2009, 15 (01) : 168 - 174
  • [35] Central venous catheters in children with haemophilia
    Ljung, R
    BLOOD REVIEWS, 2004, 18 (02) : 93 - 100
  • [36] Infectious Complications of Dialysis Access Devices
    Bagdasarian, Natasha
    Heung, Michael
    Malani, Preeti N.
    INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2012, 26 (01) : 127 - +
  • [39] Long-term follow-up of children with haemophilia - low incidence of infections with central venous access devices
    Harroche, A.
    Merckx, J.
    Salvi, N.
    Faivre, J.
    Jacqmarcq, O.
    Dazet, D.
    Makhloufi, M.
    Clairicia, M.
    Torchet, M. -F.
    Aouba, A.
    Rothschild, C.
    HAEMOPHILIA, 2015, 21 (04) : 465 - 468
  • [40] Central venous access devices in children with congenital coagulation disorders: complications and long-term outcome
    McMahon, C
    Smith, J
    Khair, K
    Liesner, R
    Hann, IM
    Smith, OP
    BRITISH JOURNAL OF HAEMATOLOGY, 2000, 110 (02) : 461 - 468