Monitoring system fouling with a model heat exchanger and an electrochemical biofilm activity probe

被引:0
|
作者
Licina, GJ [1 ]
机构
[1] Struct Integr Associates, San Jose, CA USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corrosion and fouling of piping and heat exchangers cooled by surface waters have been major sources of degradation at utility power stations, especially at nuclear plants. The fouling of a once-through service water system at a freshwater cooled nuclear plant was monitored with a sidestream test skid that contained two model heat exchangers, corrosion coupons, and an electrochemical biofilm activity probe. The system fouled rapidly under normal conditions, as shown by both the model heat exchangers and the electrochemical biofilm probe. The biofouling was shown to be controlled effectively by periodic chlorination.
引用
收藏
页码:965 / 968
页数:4
相关论文
共 50 条
  • [31] Modified Dual EKF with Machine Learning Model for Fouling Prediction of Industrial Heat Exchanger
    Kalarikkal, Resma Madhu Paruthipulli
    Subbaiah, Jayalalitha
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 41 (04) : 1013 - 1027
  • [32] Fouling Detection in a Parallel Flow Heat Exchanger via a Roesser Model Identification Procedure
    Pham, D. C.
    Mercere, G.
    Ouvrard, R.
    Poinot, T.
    Palsson, H.
    IFAC PAPERSONLINE, 2017, 50 (01): : 12866 - 12871
  • [33] A statistical model for fouling of a plate heat exchanger by whey protein solution at UHT conditions
    Fryer, PJ
    Robbins, PT
    Green, C
    Schreier, PJR
    Pritchard, AM
    Hasting, APM
    Royston, DG
    Richardon, JF
    FOOD AND BIOPRODUCTS PROCESSING, 1996, 74 (C4) : 189 - 199
  • [34] Modeling CaCO3 crystallization fouling on a heat exchanger surface - Definition of fouling layer properties and model parameters
    Paakkonen, T. M.
    Riihimaki, M.
    Simonson, C. J.
    Muurinen, E.
    Keiski, R. L.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 83 : 84 - 98
  • [35] The effect of adding minerals on fouling from whey protein concentrate - Development of a model fouling fluid for a plate heat exchanger
    Christian, GK
    Changani, SD
    Fryer, PJ
    FOOD AND BIOPRODUCTS PROCESSING, 2002, 80 (C4) : 231 - 239
  • [36] Determination of Heat Transfer Correlations for Fluids Flowing through Plate Heat Exchangers Needed for Online Monitoring of District Heat Exchanger Fouling
    Romanowicz, Tomasz
    Taler, Jan
    Jaremkiewicz, Magdalena
    Sobota, Tomasz
    ENERGIES, 2023, 16 (17)
  • [37] Study on the effect of the porous media equivalent particulate fouling model on heat transfer performance in heat exchanger channels
    Li, Jiang
    Han, Zhimin
    Liu, Wei
    Wang, Taozhi
    Chang, Hongliang
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [38] Intelligent Model for the Reliability of the Non-Intrusive Continuous Sensors Used for the Detection of Fouling-Layer in Heat Exchanger System
    Aikhuele, Daniel Osezua
    Ighravwe, Desmond E. E.
    Sorooshian, Shahryar
    APPLIED SCIENCES-BASEL, 2023, 13 (05):
  • [39] DESIGN OF INTERNAL MODEL CONTROLLER FOR A HEAT EXCHANGER SYSTEM
    Rajalakshmi, K.
    Mangaiyarkarasi, V.
    2013 INTERNATIONAL CONFERENCE ON INFORMATION COMMUNICATION AND EMBEDDED SYSTEMS (ICICES), 2013, : 899 - 903
  • [40] Model based control of the heat exchanger system with accumulative heat reservoir
    Ahpichitpongchai, Panuwat
    Kamonwattana, Kamonchanok
    Intarit, Wiriya
    Wongvanich, Napasool
    Kongratana, Viriya
    2019 19TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2019), 2019, : 1291 - 1295