Comparative Analysis of Transformer Solid Insulation Drying Methods

被引:0
|
作者
Oksana, Mazur [1 ]
Alexander, Dannik [1 ]
机构
[1] GlobeCore, Res & Dev Dept, Poltava, Ukraine
关键词
transformer; solid insulation; transformer insulation aging; solid insulation drying methods;
D O I
10.1109/EIC51169.2022.9833182
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The quality of the drying process of the transformer winding insulation can be directly correlated to the reliability and longevity of the transformer as a whole. Therefore, efficient removal of moisture from paper insulation is one of the most important stages in the manufacturing process of transformers. Throughout transformers service life, several factors (oxygen, water, temperature, etc) will have a negative effect in the insulation and will reduce its performance characteristics in a process referred to as aging. Residual moisture in the solid insulation of the transformer in combination with heat and oxygen will accelerate cellulose aging, which ultimately may cause early transformer failure. An ideal insulation drying process in factory will reduce the residual moisture to levels below 0.5% content in the bulk solid insulation while retaining a high degree of polymerization between 1000 and 800. In this article, authors look into the reasons for the degradation of cellulose insulation; consider the differences and advantages of using electrical and low-frequency heating for the drying process of solid insulation inside the transformer, as well as the effect of vacuum on the evaporation of moisture. Based on the experimental work, authors classify the most effective methods in reducing moisture content in solid insulation depending on the type and voltage of the transformer.
引用
收藏
页码:385 / 389
页数:5
相关论文
共 50 条
  • [21] TESTING METHODS FOR POWER TRANSFORMER INSULATION.
    Kamata, Y.
    1600, (EI-21):
  • [22] Insulation characteristics of perfluorocarbon liquid/solid insulation for nonflammable large power transformer
    Miyagi, K
    Horii, S
    Sugimoto, T
    ELECTRICAL ENGINEERING IN JAPAN, 1996, 116 (06) : 83 - 94
  • [23] Insulation characteristics of perfluorocarbon liquid/solid insulation for nonflammable large power transformer
    Miyagi, Katsunori
    Horii, Shigenobu
    Sugimoto, Toshiro
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1996, 116 (06): : 83 - 94
  • [24] Deterioration of solid insulation for thermal degradation of transformer oil
    Karthik, R.
    Raja, T. Sree Renga
    Sudhakar, T.
    OPEN ENGINEERING, 2013, 3 (02): : 226 - 232
  • [25] Investigation on Degradation of Power Transformer Solid Insulation Material
    Homagk, C.
    Moessner, K.
    Leibfried, T.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 268 - 271
  • [26] Diagnostics of thermal aging of transformer bushings with solid insulation
    Subocz, Jan
    Zenker, Marek
    Mrozik, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5A): : 86 - 89
  • [27] World's first solid insulation distribution transformer
    Paradis, Claude
    Chaaban, Mohamed
    Blouin, Pierre P.
    ABB Review, 1998, (05): : 21 - 27
  • [28] Monitoring and Diagnostic Techniques of Power Transformer Solid Insulation
    Wang, Jie
    Zheng, Jian
    Hu, Shuilian
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 77 - 80
  • [29] Study on the Transformer Solid Insulation Aging Diagnosis Method
    Mu Xueyun
    Yang Qiping
    Wang Jun
    Xu Danfeng
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [30] Experimental investigation of distribution transformer aged solid insulation
    Mousavi, MJ
    Butler-Purry, KL
    2002 45TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2002, : 192 - 195