On the prediction of Young's modulus in calcaneal cancellous bone by ultrasonic bulk and bar velocity measurements

被引:17
|
作者
Nicholson, PHF [1 ]
Strelitzki, R [1 ]
机构
[1] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
关键词
bone mineral density; cancellous bone; elastic modulus; ultrasound; velocity;
D O I
10.1007/s100670050044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated two different approaches to the prediction of Young's modulus (E) from ultrasonic velocity and density measurements in 23 cubes of cancellous bone from human calcaneae. The first approach used clinically applicable measurements of bulk velocity and bone mineral density (BMD), whilst the second involved bar velocity and apparent density, which are strictly in vitro measurements. Bulk velocities were measured with an immersion technique with 1 MHz transducers using three different transit time markers (first arrival, thresholding, zero-crossing). Bar velocities were measured in the defatted specimens using a contact technique with 37 kHz transducers in air. Volumetric BMD was derived from dual-energy X-ray absorptiometry measurements, and apparent density was measured directly. Compressive mechanical testing was used to determine E. Bulk velocity, bar velocity and E all displayed significant anisotropy, being greatest in the proximo-distal (PD) axis and least in the medio-lateral (ML) axis. Bulk velocity was dependent on the transit time marker used, with velocity differences of up to 20% observed between different markers. Bar velocities were significantly lower than bulk velocities in all directions. Both bulk and bar velocities correlated with E (r(2) = 0.26-0.83, r(2) = 0.36-0.81, respectively) with stronger relationships obtained when the data for the three axes were pooled. The predictive ability of bulk velocities determined using different markers was similar. In general, combining velocity and density measurements yielded improved correlations with E. Thus, strong correlations were observed between E and the product of BMD and bulk velocity(2) (r(2) = 0.58-0.89), and the product of apparent density and bar velocity(2) (r(2) = 0.58-0.89). These results demonstrate that clinically applicable measurements of bulk velocity and BMD are good predictors of the elastic modulus of calcaneal bone, and that bulk and bar velocity, both alone and when combined with density measurements, have a similar predictive ability for mechanical properties.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 50 条
  • [31] YOUNG MODULUS, DENSITY AND MATERIAL PROPERTIES IN CANCELLOUS BONE OVER A LARGE DENSITY RANGE
    HODGSKINSON, R
    CURREY, JD
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (05) : 377 - 381
  • [32] Micro-cantilever bending for elastic modulus measurements of a single trabecula in cancellous bone
    Yamada, Satoshi
    Tadano, Shigeru
    Fukasawa, Koichi
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 4124 - 4127
  • [33] Backscatter-difference Measurements of Cancellous Bone Using an Ultrasonic Imaging System
    Hoffmeister, Brent K.
    Smathers, Morgan R.
    Miller, Catherine J.
    McPherson, Joseph A.
    Thurston, Cameron R.
    Spinolo, P. Luke
    Lee, Sang-Rok
    ULTRASONIC IMAGING, 2016, 38 (04) : 285 - 297
  • [34] Cancellous bone Young's modulus variation within the vertebral body of a ligamentous lumbar spine - Application of bone adaptive remodeling concepts
    Goel, V.K.
    Ramirez, S.A.
    Kong, W.
    Gilbertson, L.G.
    Journal of Biomechanical Engineering, 1995, 117 (03): : 266 - 271
  • [35] Variations in ultrasonic wave velocity and dynamic Young's modulus with moisture content for Taiwania plantation lumber
    Wang, SY
    Chiu, CM
    Lin, CJ
    WOOD AND FIBER SCIENCE, 2002, 34 (03): : 370 - 381
  • [36] Young’s modulus of cast HMS 2112-Cf composite—prediction and ultrasonic evaluation
    K G Satyanarayana
    M Vishnu Nampoothiri
    S Adalarasu
    S Mahadevan
    Bulletin of Materials Science, 1998, 21 : 323 - 327
  • [37] Study on the Dependence of Ultrasonic Phase Velocity on Pomsity, Frequency and Pmpagation Angle in Cancellous Bone
    Lee, Kang Il
    Kim, Yong Tae
    Choi, Min Joo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2008, 28 (02) : 112 - 118
  • [38] Relationships between ultrasonic attenuation, velocity and backscatter and cancellous bone micro-architecture.
    Chaffai, S
    Peyrin, F
    Berger, G
    Laugier, P
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S376 - S376
  • [40] Determining young's modulus by measurement of sound velocity
    Bauer, D
    Krebs, R
    Stohl, D
    METALL, 1999, 53 (12): : 669 - 671