Influence of ocular chromatic aberration and pupil size on transverse resolution in ophthalmic adaptive optics optical coherence tomography

被引:31
|
作者
Fernández, EJ
Drexler, W
机构
[1] Vienna Univ Med, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Univ Murcia, Dept Phys, Lab Opt, Murcia, Spain
[3] Vienna Univ Med, Ctr Biomed Engn & Phys, Vienna, Austria
来源
OPTICS EXPRESS | 2005年 / 13卷 / 20期
关键词
D O I
10.1364/OPEX.13.008184
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) enables visualization of the living human retina with unprecedented high axial resolution. The transverse resolution of existing OCT approaches is relatively modest as compared to other retinal imaging techniques. In this context, the use of adaptive optics (AO) to correct for ocular aberrations in combination with OCT has recently been demonstrated to notably increase the transverse resolution of the retinal OCT tomograms. AO is required when imaging is performed through moderate and large pupil sizes. A fundamental difference of OCT as compared to other imaging techniques is the demand of polychromatic light to accomplish high axial resolution. In ophthalmic OCT applications, the performance is therefore also limited by ocular chromatic aberrations. In the current work, the effects of chromatic and monochromatic ocular aberrations on the quality of retinal OCT tomograms, especially concerning transverse resolution, sensitivity and contrast, are theoretically studied and characterized. The repercussion of the chosen spectral bandwidth and pupil size on the final transverse resolution of OCT tomograms is quantitatively examined. It is found that losses in the intensity of OCT images obtained with monochromatic aberration correction can be up to 80 %, using a pupil size of 8 mm diameter in combination with a spectral bandwidth of 120 nm full width at half maximum for AO ultrahigh resolution OCT. The limits to the performance of AO for correction of monochromatic aberrations in OCT are established. The reduction of the detected signal and the resulting transverse resolution caused by chromatic aberration of the human eye is found to be strongly dependent on the employed bandwidth and pupil size. Comparison of theoretical results with experimental findings obtained in living human eyes is also provided. (c) 2005 Optical Society of America.
引用
收藏
页码:8184 / 8197
页数:14
相关论文
共 50 条
  • [31] High resolution retinal imaging with a compact adaptive optics spectral domain optical coherence tomography system
    Hammer, Daniel X.
    Iftimia, Nicusor V.
    Bigelow, Chad E.
    Ustun, Teoman E.
    Bloom, Benjamin
    Ferguson, R. Daniel
    Burns, Stephen A.
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [32] Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging
    Zawadzki, Robert J.
    Jones, Steven M.
    Pilli, Suman
    Balderas-Mata, Sandra
    Kim, Dae Yu
    Olivier, Scot S.
    Werner, John S.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06): : 1674 - 1686
  • [33] Acute Solar Retinopathy Imaged With Adaptive Optics, Optical Coherence Tomography Angiography, and En Face Optical Coherence Tomography
    Wu, Chris Y.
    Jansen, Michael E.
    Andrade, Jorge
    Chui, Toco Y. P.
    Do, Anna T.
    Rosen, Richard B.
    Deobhakta, Avnish
    JAMA OPHTHALMOLOGY, 2018, 136 (01) : 82 - 85
  • [34] Wide-field whole eye optical coherence tomography with ocular pupil tracking
    Funkenbusch, George Tian
    Laoprasert, Rick
    Ortiz, Pablo
    Young, Terri L.
    Izatt, Joseph A.
    Kuo, Anthony N.
    McNabb, Ryan P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [35] A method to correct longitudinal chromatic aberration between imaging and beacon beams of ocular adaptive optics imaging system
    Qiu Y.
    Yang Y.
    Liu Y.
    Yue X.
    Zhang Y.
    1600, IOP Publishing Ltd (22):
  • [36] Adaptive optics optical coherence tomography angiography in healthy volunteers and patients
    Salas, Matthias
    Augustin, Marco
    Ginner, Laurin
    Baumann, Bernhard
    Leitgeb, Rainer A.
    Hafner, Julia
    Prager, Sonja
    Ritter, Markus
    Schmidt-Erfurth, Ursula
    Drexler, Wolfgang
    Pircher, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] Error Budget Analysis for an Adaptive Optics Optical Coherence Tomography System
    Evans, Julia W.
    Zawadzki, Robert J.
    Jones, Steven M.
    Olivier, Scot S.
    Werner, John S.
    OPTICS EXPRESS, 2009, 17 (16): : 13768 - 13784
  • [38] Computations adaptive optics in phase-unstable optical coherence tomography
    Ruiz-Lopera, Sebastian
    Restrepo, Rene
    Cuartas-Velez, Carlos
    Bouma, Brett E.
    Uribe-Patarroyo, Nestor
    OPTICS LETTERS, 2020, 45 (21) : 5982 - 5985
  • [39] Towards model-based adaptive optics optical coherence tomography
    Verstraete, Hans R. G. W.
    Cense, Barry
    Bilderbeek, Rolf
    Verhaegen, Michel
    Kalkman, Jeroen
    OPTICS EXPRESS, 2014, 22 (26): : 32406 - 32418
  • [40] Automated Vessel Segmentation in Adaptive Optics - Optical Coherence Tomography Images
    Le, Christopher
    Wang, Dongyi
    Villanueva, Ricardo
    Liu, Zhuolin
    Hammer, Daniel
    Saeedi, Osamah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)