Dose and dose rate dependence of time-resolved OSL from Korean paleosol quartz

被引:7
|
作者
Kim, M. J. [1 ]
Choi, J. H. [2 ]
Hong, D. G. [1 ]
机构
[1] Kangwon Natl Univ, Dept Phys, Chunchon 200701, Gangwon Do, South Korea
[2] Korea Basic Sci Inst, Geochronol Team, Taejon 305333, South Korea
关键词
TR-OSL; Dose dependence; Dose rate dependence; X-ray irradiation; OPTICALLY STIMULATED LUMINESCENCE; POINT-DEFECTS;
D O I
10.1016/j.radmeas.2011.03.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Using a newly developed small X-ray irradiator equipped with a mini X-ray generator (Varian VF-50J) and TR-OSL measurement system attached to an MCS (ORTEC MCS-PCI), the influence of dose and dose rate of X-ray radiation on TR-OSL was investigated in paleosol quartz from the Chungdang-dong paleolithic site, Korea. All lifetimes were calculated by a curve-fitting method using a single stretched-exponential function with beta = 0.86. Physical characteristics, natural lifetime, thermal quenching activation energy Delta E, and thermal assistance activation energy E-a were firstly determined. From the results of the investigation of dependence on dose and dose rate of X-ray radiation using fully bleached samples, the lifetime decreased significantly to about 20 its: when the X-ray dose was increased to 300 Gy at a dose rate of 0.5 Gy/s. Also, despite different radiation dose rates, at a dose of 50 Gy both lifetime and related intensity were independent of dose rate change. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1518 / 1521
页数:4
相关论文
共 50 条
  • [31] Quartz thermoluminescence: Dose and dose-rate effects and their implications
    Physical Research Lab, Ahmedabad, India
    Radiat Meas, 1 (53-63):
  • [32] OBSERVATION OF A DOSE-RATE DEPENDENCE IN THE PRODUCTION OF POINT-DEFECTS IN QUARTZ
    MONDRAGON, MA
    CHEN, CY
    HALLIBURTON, LE
    JOURNAL OF APPLIED PHYSICS, 1988, 63 (10) : 4937 - 4941
  • [33] Quartz thermoluminescence: Dose and dose-rate effects and their implications
    Chawla, S
    Rao, TKG
    Singhvi, AK
    RADIATION MEASUREMENTS, 1998, 29 (01) : 53 - 63
  • [34] TESTING THE SUITABILITY OF DIM SEDIMENTARY QUARTZ FROM NORTHERN SWITZERLAND FOR OSL BURIAL DOSE ESTIMATION
    Trauerstein, Mareike
    Lowick, Sally E.
    Preusser, Frank
    Veit, Heinz
    GEOCHRONOMETRIA, 2017, 44 (01): : 66 - 76
  • [35] Towards models for analysis of time-resolved luminescence spectra from quartz
    Chithambo, ML
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (06) : 941 - 942
  • [36] Time-resolved luminescence of low sensitivity quartz from crystalline rocks
    Chithambo, M. L.
    Preusser, F.
    Ramseyer, K.
    Ogundare, F. O.
    RADIATION MEASUREMENTS, 2007, 42 (02) : 205 - 212
  • [37] Time-resolved luminescence from quartz: An overview of contemporary developments and applications
    Chithambo, M. L.
    Ankjaergaard, C.
    Pagonis, V.
    PHYSICA B-CONDENSED MATTER, 2016, 481 : 8 - 18
  • [38] The dose dependence and the firing effects on the thermoluminescence of quartz
    Halperin, Abraham
    Physica Status Solidi C - Current Topics in Solid State Physics, Vol 4, No 3, 2007, 4 (03): : 988 - 991
  • [39] RADIOSENSITIVITY OF LYMPHOCYTES - DOSE AND DOSE-RATE DEPENDENCE
    BABINI, L
    BARBIERI, E
    CECCHETTI, E
    EMILIANI, E
    TESTONI, N
    ZACCARIA, A
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1987, 51 (04) : 741 - 741
  • [40] Fundamental investigations of natural and laboratory generated SAR dose response curves for quartz OSL in the high dose range
    Timar-Gabor, A.
    Constantin, D.
    Buylaert, J. P.
    Jain, M.
    Murray, A. S.
    Wintle, A. G.
    RADIATION MEASUREMENTS, 2015, 81 : 150 - 156