Determination of total ionic polysulfides by differential pulse polarography

被引:15
|
作者
Kariuki, S
Morra, MJ [1 ]
Umiker, KJ
Cheng, IF
机构
[1] Univ Idaho, Soil Sci Div, Moscow, ID 83844 USA
[2] Univ Idaho, Dept Chem, Moscow, ID 83844 USA
关键词
ionic polysulfides; sulfide; polythionates; differential pulse polarography;
D O I
10.1016/S0003-2670(01)01171-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ionic polysulfides occur in various natural environments and waste waters from industrial processes; however, their direct determination in samples containing additional sulfur species has remained a challenge. Our goal was to develop a polarographic technique that could be used to directly determine total ionic polysulfides in the presence of other sulfur species such as polythionates and sulfide. Ionic polysulfides in an aqueous carbonate buffer (pH 9.5) were measured using differential pulse polarography (DPP) in combination with a dropping mercury electrode. An adsorption phenomenon associated with polysulfide or a product of its cathodic reaction with the Hg electrode created a characteristic current minimum at -1000 mV with a magnitude proportional to the concentration of S(0) existing in the form of polysulfidic sulfur. Sulfide and thiosulfate did not interfere and polythionates caused only a decrease in the magnitude of the minimum. The specificity of the technique and the lack of significant interferences make it an attractive alternative for the measurements of samples with polysulfidic sulfur concentrations between 10(-5) and 10(-3) M. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 50 条
  • [41] Determination of Sulfite in Wine Using Differential Pulse Polarography
    Somer, Guler
    Kalayci, Sukru
    Yilmaz, Ummihan
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (12) : 1360 - 1365
  • [42] Indirect determination of ephedrine in urine by differential pulse polarography
    Hernandez, L
    Zapardiel, A
    Bermejo, E
    Perez, JA
    Chicharro, M
    Garijo, MJ
    ELECTROANALYSIS, 1997, 9 (15) : 1214 - 1218
  • [43] Determination of entacapone by differential pulse polarography in pharmaceutical formulation
    Abasq, Marie-Laurence
    Courtel, Patricia
    Burgot, Gwenola
    ANALYTICAL LETTERS, 2008, 41 (01) : 56 - 65
  • [44] DETERMINATION OF RONIDAZOLE IN SWINE TISSUES BY DIFFERENTIAL PULSE POLAROGRAPHY
    CALA, PC
    DOWNING, GV
    MICHIELLI, RF
    WITTICK, JJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1976, 24 (04) : 764 - 767
  • [45] DETERMINATION OF ALLOPURINOL IN TABLETS BY DIFFERENTIAL-PULSE POLAROGRAPHY
    CHATTEN, LG
    BOYCE, M
    MOSKALYK, RE
    PONS, BS
    MADAN, DK
    ANALYST, 1981, 106 (1260) : 365 - 368
  • [46] Determination of niobium in pyrochlore ore by differential pulse polarography
    Lichtig, J
    Andrade, RF
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 559 - 561
  • [47] Determination of Sulfite in Wine Using Differential Pulse Polarography
    Şükrü Güler Somer
    Ümmihan Kalaycı
    Russian Journal of Electrochemistry, 2019, 55 : 1360 - 1365
  • [48] DETERMINATION OF BIPYRIDYLIUM HERBICIDES BY THE DIFFERENTIAL PULSE POLAROGRAPHY METHOD
    POLAK, J
    VOLKE, J
    CHEMICKE LISTY, 1983, 77 (11): : 1190 - 1195
  • [49] DETERMINATION OF SOME AMINOGLYCOSIDE ANTIBIOTICS BY DIFFERENTIAL PULSE POLAROGRAPHY
    PERRUCHON, P
    CAULLET, C
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 112 (02) : 397 - 402
  • [50] DETERMINATION OF BENZOYLMETRONIDAZOLE IN SUSPENSION FORMULATIONS BY DIFFERENTIAL PULSE POLAROGRAPHY
    DALKARA, S
    ONG, H
    BRAUN, J
    PLOURDE, R
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1984, 17 (09): : 793 - 804