Effect of air flow on corona discharge in wire-to-plate electrostatic precipitator

被引:25
|
作者
Said, H. Ait [1 ]
Nouri, H. [1 ,2 ]
Zebboudj, Y. [1 ]
机构
[1] Univ A Mira de Bejaia, Lab Genie Elect, Bejaia 06000, Algeria
[2] Univ Setif 1, Dept Elect Engn, Setif 19000, Algeria
关键词
Corona discharge; Electrostatic precipitator; Current density; Electric field; Air flow; ELECTROHYDRODYNAMIC FLOW; PLANE CORONA; FIELD; HUMIDITY; PROBE;
D O I
10.1016/j.elstat.2014.10.004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper analyses corona discharge in ambient air with laboratory-scaled wire-to-plate electrostatic precipitator (WPESP). The electric field is behind the electro hydrodynamic (EHD) flow in air. Its measurements provide complementary results for the corona discharge study because the classical theory based on the current and voltage data is unsatisfactory. Taking into account the dynamic air flow velocity is perpendicular to the active wires, measurement method of the positive and negative DC corona current density and electric field, has been introduced. It has been shown also that the dynamic air flow velocity modifies the current density and the electric field distributions on the planes surfaces of the WPESP. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [21] Effects of corona wire distribution on characteristics of electrostatic precipitator
    Wang, Xiaohua
    [J]. POWDER TECHNOLOGY, 2020, 366 : 36 - 42
  • [22] OZONE GENERATION IN AN ELECTROSTATIC PRECIPITATOR WITH A HEATED CORONA WIRE
    AWAD, MB
    CASTLE, GSP
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1975, 25 (04): : 369 - 374
  • [23] Velocity field of EHD flow during back corona discharge in electrostatic precipitator
    Krupa, A.
    Podlinski, J.
    Mizeraczyk, J.
    Jaworek, A.
    [J]. POWDER TECHNOLOGY, 2019, 344 : 475 - 486
  • [24] An analysis of a wire-plate electrostatic precipitator
    Zhang, XR
    Wang, LZ
    Zhu, KQ
    [J]. JOURNAL OF AEROSOL SCIENCE, 2002, 33 (11) : 1595 - 1600
  • [25] THE EFFECT OF CORONA WIRE HEATING ON THE DOWNSTREAM OZONE CONCENTRATION PROFILES IN AN AIR-CLEANING WIRE-DUCT ELECTROSTATIC PRECIPITATOR
    OHKUBO, T
    HAMASAKI, S
    NOMOTO, Y
    CHANG, JS
    ADACHI, T
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (03) : 542 - 549
  • [26] SCALING OF WIRE SEPARATION IN PLATE-WIRE ELECTROSTATIC PRECIPITATOR
    SAMUEL, EA
    KIM, YW
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (10): : 1292 - 1292
  • [27] Computational Fluid Dynamic Modelling of Particle Charging and Collection in a Wire-to-Plate Type Single-Stage Electrostatic Precipitator
    Park, Ji-Woon
    Kim, Chul
    Park, Jaehong
    Hwang, Jungho
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (03) : 590 - 601
  • [28] On the modeling of electro-hydrodynamic flow in a wire-plate electrostatic precipitator
    Chun, Young Nam
    Yeom, Dong Seok
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2006, 23 (04) : 560 - 565
  • [29] Numerical simulation of the electrohydrodynamic flow in a single wire-plate electrostatic, precipitator
    Zhao, Lin
    Adamiak, Kazimierz
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (03) : 683 - 691
  • [30] Electrohydrodynamic gas flow regime map in a wire-plate electrostatic precipitator
    Chang, JS
    Dekowski, J
    Podlinski, J
    Brocilo, D
    Urashima, K
    Mizeraczyk, J
    [J]. CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 2597 - 2600