摘要
This paper analyses corona discharge in ambient air with laboratory-scaled wire-to-plate electrostatic precipitator (WPESP). The electric field is behind the electro hydrodynamic (EHD) flow in air. Its measurements provide complementary results for the corona discharge study because the classical theory based on the current and voltage data is unsatisfactory. Taking into account the dynamic air flow velocity is perpendicular to the active wires, measurement method of the positive and negative DC corona current density and electric field, has been introduced. It has been shown also that the dynamic air flow velocity modifies the current density and the electric field distributions on the planes surfaces of the WPESP. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [1] Analysis of positive corona in wire-to-plate electrostatic precipitator
    Nouri, H.
    Zebboudj, Y.
    [J]. EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2010, 49 (01):
  • [2] Modelling of near corona wire electrohydrodynamic flow in a wire-plate electrostatic precipitator
    Chun, YN
    Berezin, AA
    Brocilo, D
    Mizeraczyk, J
    Chang, JS
    [J]. 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 478 - 481
  • [3] Simulation and measurement of charged particle trajectory with ionic flow in a wire-to-plate type electrostatic precipitator
    Ito, Kohei
    Tamura, Ryota
    Zukeran, Akinori
    Kawada, Yoshihiro
    Taoka, Tomohiro
    [J]. JOURNAL OF ELECTROSTATICS, 2020, 107
  • [4] Dimensional analysis of detrimental ozone generation by positive wire-to-plate corona discharge in air
    Bo, Z.
    Chen, J. H.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (06)
  • [5] Numerical modeling of near corona wire electrohydrodynamic flow in a wire-plate electrostatic precipitator
    Chun, Young Nam
    Chang, Jen-Shih
    Berezin, Alexander A.
    Mizeraczyk, J.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) : 119 - 124
  • [6] Ion source for IMS based on wire-to-plate corona discharge
    Qing Xia
    Yu Zhang
    Jiting Ouyang
    [J]. The European Physical Journal Special Topics, 2017, 226 : 2955 - 2964
  • [7] Ion source for IMS based on wire-to-plate corona discharge
    Xia, Qing
    Zhang, Yu
    Ouyang, Jiting
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2017, 226 (13): : 2955 - 2964
  • [8] Corona discharge simulation in wire-duct electrostatic precipitator
    Anagnostopoulos, J
    Bergeles, G
    [J]. JOURNAL OF ELECTROSTATICS, 2002, 54 (02) : 129 - 147
  • [9] An experimental study on the performance of a single discharge wire-plate electrostatic precipitator with back corona
    Chang, CL
    Bai, HL
    [J]. JOURNAL OF AEROSOL SCIENCE, 1999, 30 (03) : 325 - 340
  • [10] Study of a Wire-to-Plate Positive Pulsed Corona Discharge Reactor by Emission Spectroscopy
    Wang Shen-bing
    Luo Zhong-yang
    Zhao Lei
    Xuan Jian-yong
    Jiang Jian-ping
    Cen Ke-fa
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (11) : 2896 - 2900