Quantitative evaluation of a cone-beam computed tomography-planning computed tomography deformable image registration method for adaptive radiation therapy

被引:78
|
作者
Lawson, Joshua D. [1 ]
Schreibmann, Eduard [1 ]
Jani, Ashesh B. [1 ]
Fox, Tim [1 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
来源
关键词
image-guided radiation therapy; deformable image registration; adaptive radiotherapy;
D O I
10.1120/jacmp.v8i4.2432
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deformable (non-rigid) registration is an essential tool in both adaptive radiation therapy and image-guided radiation therapy to account for soft-tissue changes during the course of treatment. The evaluation method most commonly used to assess the accuracy of deformable image registration is qualitative human evaluation. Here, we propose a method for systematically measuring the accuracy of an algorithm in recovering artificially introduced deformations in cases of rigid geometry, and we use that method to quantify the ability of a modified basis spline (B-Spline) registration algorithm to recover artificially introduced deformations. The evaluation method is entirely computer-driven and eliminates biased interpretation associated with human evaluation; it can be applied to any chosen method of image registration. Our method involves using planning computed tomography (PCT) images acquired with a conventional CT simulator and cone-beam computed tomography (CBCT) images acquired daily by a linear accelerator-mounted kilovoltage image system in the treatment delivery room. The deformation that occurs between the PCT and daily CBCT images is obtained using a modified version of the B-Spline deformable model designed to overcome the low soft-tissue contrast and the artifacts and distortions observed in CBCT images. Clinical CBCT images and contours of phantom and central nervous system cases were deformed (warped) with known random deformations. In registering the deformed with the non-deformed image sets, we tracked the algorithm's ability to recover the original, non-deformed set. Registration error was measured as the mean and maximum difference between the original and the registered surface contours from outlined structures. Using this approach, two sets of tests can be devised. To measure the residual error related to the optimizer's convergence performance, the warped CBCT image is registered to the unwarped version of itself, eliminating unknown factors such as noise and positioning errors. To study additional errors introduced by artifacts and noise in the CBCT image, the warped CBCT image is registered to the original PCT image. Using a B-Spline deformable image registration algorithm, mean residual error introduced by the algorithm's performance on noise-free images was less than 1 mm, with a maximum of 2 mm. The chosen deformable image registration model was capable of accommodating significant variability in structures over time, because the artificially introduced deformation magnitude did not significantly influence the residual error. On the second type of test, noise and artifacts reduced registration accuracy to a mean of 1.33 mm and a maximum of 4.86 mm. The accuracy of deformable image registration can be easily and consistently measured by evaluating the algorithm's ability to recover artificially introduced deformations in rigid cases in which the true solution is known a priori. The method is completely automated, applicable to any chosen registration algorithm, and does not require user interaction of any kind.
引用
收藏
页码:96 / 113
页数:18
相关论文
共 50 条
  • [1] Quantitative evaluation of a cone beam computed tomography (CBCT)-CT deformable image registration method for adaptive radiation therapy
    Lawson, J. D.
    Schreibmann, E.
    Jani, A. B.
    Fox, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S709 - S709
  • [2] Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, Salim
    Weiss, Elisabeth
    Jan, Nuzhat
    Roman, Nicholas
    Sleeman, William C.
    Fatyga, Mirek
    Christensen, Gary E.
    Zhang, Cheng
    Murphy, Martin J.
    Lu, Jun
    Keall, Paul
    Williamson, Jeffrey F.
    Hugo, Geoffrey D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 372 - 379
  • [3] Deformable registration of lateral cephalogram and cone-beam computed tomography image
    Zhang, Yungeng
    Qin, Haifang
    Li, Peixin
    Pei, Yuru
    Guo, Yuke
    Xu, Tianmin
    Zha, Hongbin
    [J]. MEDICAL PHYSICS, 2021, 48 (11) : 6901 - 6915
  • [4] Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Williamson, Tyler D.
    Yang, Jinzhong
    Wisdom, Paul G.
    Zhu, Xiaorong R.
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary B.
    Gao, Song
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 92 - 100
  • [5] The Impact of Cone-Beam Computed Tomography (CBCT) Artifacts on Deformable Image Registration Algorithms
    Ueda, U.
    Hu, W.
    Pouliot, J.
    Yom, S.
    Quivey, J.
    Aubin, M.
    Chen, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3091 - +
  • [6] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    [J]. ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [7] Unsupervised computed tomography and cone-beam computed tomography image registration using a dual attention network
    Hu, Rui
    Yan, Hui
    Nian, Fudong
    Mao, Ronghu
    Li, Teng
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (07) : 3705 - 3716
  • [8] Evaluation of Deformable Prostate Cone Beam Computed Tomography (CBCT) Contouring Methods for Adaptive Radiation Therapy
    Pirozzi, S.
    Piper, J.
    Nelson, A.
    Shen, Z.
    Gardner, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S719 - S719
  • [9] Evaluation of Megavoltage Cone-Beam Computed Tomography Doses in Thoracic Radiation Therapy
    Yan, S.
    Zhu, J.
    Yan, S.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Stereotactic registration using cone-beam computed tomography
    Carlson, Jonathan Dennis
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 182 : 107 - 111