4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapy

被引:8
|
作者
Nakagawa, Keiichi [1 ]
Kida, Satoshi [1 ]
Haga, Akihiro [1 ]
Masutani, Yoshitaka [1 ]
Yamashita, Hideomi [1 ]
Onoe, Tsuyoshi [1 ]
Imae, Toshikazu [1 ]
Tanaka, Kenichiro [1 ]
Ohtomo, Kuni [1 ]
Yoda, Kiyoshi [2 ]
机构
[1] Tokyo Univ Hosp, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
[2] Elekta KK, Minato Ku, Tokyo 1080023, Japan
关键词
DRR; VMAT; 4D; in-treatment; BEAM COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; CT;
D O I
10.1093/jrr/rrs013
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have proposed four dimensional (4D) digitally reconstructed radiography (DRR) for verifying a lung tumor position during volumetric modulated arc therapy (VMAT). An internal target volume (ITV) was defined based on two clinical target volumes (CTVs) delineated on maximum exhalation and maximum inhalation images acquired by 4D planning computed tomography (CT). A planning target volume (PTV) was defined by adding a margin of 5 mm to the ITV on the maximum exhalation 3D CT images. A single-arc VMAT plan was created on the same CT data using Pinnacle Smart Arc with a maximum multi-leaf collimator leaf speed of 1 mm/degree, thereby resulting in quasi-conformal field shapes while optimizing each beam intensity for each gantry angle. During VMAT delivery, cone-beam CT (CBCT) projection data were acquired by an on-board kilovoltage X-ray unit and a flat panel 2D detector. Four CBCT image sets with different respiratory phases were reconstructed using in-house software, where respiratory phases were extracted from the projection data. Subsequently a CTV was delineated on each of the 4D CBCT images by an oncologist. Using the resulting 4D CBCT data including the CTV contours, 4D DRRs during the VMAT delivery were calculated as a function of gantry angle. It was confirmed that the contoured CTV was within the radiation field during the four-fraction lung VMAT delivery. The proposed 4D DRR may facilitate the verification of the position of a respiratory moving lung tumor during VMAT delivery on each treatment day.
引用
收藏
页码:628 / 632
页数:5
相关论文
共 50 条
  • [41] Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT
    Weiss, E.
    Wijesooriya, K.
    Dill, S. V.
    Keall, P. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S484 - S484
  • [42] RADIOLOGICAL AND CLINICAL PNEUMONITIS AFTER STEREOTACTIC LUNG RADIOTHERAPY: A MATCHED COMPARISON OF 3D-CONFORMAL AND VOLUMETRIC MODULATED ARC THERAPY TECHNIQUES
    Palma, D.
    Senan, S.
    Haasbeek, C. J. A.
    Verbakel, W.
    Vincent, A.
    Lagerwaard, F. J.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (05) : S68 - S68
  • [43] Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients
    Liang, Jian
    Lack, Danielle
    Zhou, Jun
    Liu, Qiang
    Grills, Inga
    Di Yan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 10 - 24
  • [44] Factors Affecting Prostate Displacement During Volumetric Modulated Arc Therapy in Prone Position After High-Dose-Rate Brachytherapy for Prostate Cancer
    Sakurai, Takayuki
    Takamatsu, Shigeyuki
    Shibata, Satoshi
    Minamikawa, Risako
    Yamazaki, Masahiro
    Kojima, Hironori
    Noto, Kimiya
    Makino, Tomoyuki
    Kawaguchi, Shohei
    Nohara, Takahiro
    Mizokami, Atsushi
    Gabata, Toshifumi
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
  • [45] Dosimetric Impact of the Interplay Effect During Stereotactic Lung Radiation Therapy Delivery Using Flattening Filter-Free Beams and Volumetric Modulated Arc Therapy
    Ong, Chin Loon
    Dahele, Max
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (04): : 743 - 748
  • [46] A Novel 4D Robust Optimization Mitigates Interplay Effect in Intensity-Modulated Proton Therapy for Lung Cancer
    Liu, W.
    Schild, S.
    Chang, J.
    Liao, Z.
    Wen, Z.
    Shen, J.
    Stoker, J.
    Wong, W.
    Sahoo, N.
    Herman, M.
    Mohan, R.
    Bues, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3525 - 3525
  • [47] Comparing phase- and amplitude-gated volumetric modulated arc therapy for stereotactic body radiation therapy using 3D printed lung phantom
    Lee, Minsik
    Yoon, KyoungJun
    Cho, Byungchul
    Kim, Su Ssan
    Song, Si Yeol
    Choi, Eun Kyung
    Ahn, SeungDo
    Lee, Sang-Wook
    Kwak, JungWon
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (02): : 107 - 113
  • [48] Estimation of Uncertainty in Dose Delivery Due to MLC Position Inaccuracies by Inverse Derivative Method During Volumetric Modulated Arc Therapy Delivery by Elekta Beam Modulator
    Sarkar, B.
    Nandy, M.
    Manikandan, A.
    Basu, P.
    Sujatha, N.
    Ray, D. K.
    Senthilkumar, P.
    Ray, S.
    Roy, S. Sinha
    Ray, A.
    Basu, S.
    Bhattacharya, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3715 - 3715
  • [49] Does Midtreatment Cone Beam Computed Tomography-Guided Patient Repositioning During Lung Volumetric Modulated Arc Therapy Impact Target Coverage?
    Mathieu, D.
    Campeau, M. P.
    Doucet, R.
    Zerouali, K.
    Bedwani, S.
    Bahig, H.
    Lambert, L.
    Vu, T. T. T.
    Roberge, D.
    Filion, E. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E652 - E652
  • [50] 4D cone beam CT imaging to assess the influence of a respiratory monitoring system on the tumor amplitude and tumor mean position in lung cancer patients
    Rossi, MMG.
    Sonke, J-J.
    Wolthaus, J.
    Belderbos, J.
    Schneider, C.
    van Herk, M.
    Lebesque, J.
    Damen, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S144 - S145