A Study on Nonlinear Dynamic Response of the Large-Span Roof Structure with Suspended Substructure

被引:1
|
作者
Pan, Rui [1 ]
Zheng, Baofeng [1 ]
Qin, Ying [1 ]
机构
[1] Southeast Univ, Natl Prestress Engn Res Ctr, Minist Educ, Key Lab C & PC Struct, Nanjing 211189, Peoples R China
来源
SYMMETRY-BASEL | 2021年 / 13卷 / 12期
基金
中国国家自然科学基金;
关键词
large-span roof structure; substructure; nonlinear vibration; analytical solution; BUILDING SYSTEMS; FLOOR SLABS; VIBRATION; PENDULUM; DESIGN; OPTIMIZATION; WIND;
D O I
10.3390/sym13122397
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Nowadays, it is common to see large public buildings, e.g., stadiums, with some equipment or substructure suspended from the center of the roof. These substructures will tend to be larger and heavier the more gear is needed, which may have negative impacts on the dynamic performance of the roof structures. In this paper, to explore the dynamic response of a large-span roof structure with a suspended substructure, a real structure model is simplified into a two-degrees-of-freedom system. The essential consideration of nonlinear vibration is elaborated in the equations of motions. Approximate analytical solutions for free and forced vibrations are derived using perturbation methods, while numerical analysis is carried out to validate the solutions. The ratio of linear to nonlinear amplitude is proposed to represent the nonlinear effect of the primary structure, and the nonlinear effect, varying with structural parameters of frequency ratio, mass ratio, excitation ratio, and external force to the primary structure, is investigated. It is shown that internal resonance occurs when the structural frequency ratio is close to 1:2 and that secondary resonance takes place due to certain external excitations; internal resonance and secondary resonance will magnify the amplitude of the primary structure during vibration. Finally, a case of a designed practical dome with a suspended substructure is studied to verify the outcomes from the above research. According to these findings, some design proposals for this type of structure are provided.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] THE STUDY OF ROOF STRUCTURE SOLUTIONS FOR LARGE-SPAN HANGARS
    Shi, Yong-Jiu
    Pei, Yong-Zhong
    Wang, Yuan-Qing
    [J]. PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1101 - 1105
  • [2] Study on extreme cases for large-span retractable roof structure
    Chen, Yiyi
    Jiang, Xiaofeng
    Chen, Yangji
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2007, 28 (01): : 21 - 27
  • [3] Wind Pressure Distribution on a Large-Span roof Structure
    Wang, Qinhua
    Shi, Biqing
    Zhang, Lele
    [J]. PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 234 - 238
  • [4] Experimental study on large-span glubam roof trusses
    [J]. Xiao, Yan (yanxiao@njtech.edu.cn), 1600, Science Press (37):
  • [5] Innovative design of a suspended large-span exhibition hall roof in Wuzhen, China
    Zhang, Zhun
    Yuan, Philip
    Huang, Tao
    Wang, Rui
    Han, Li
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 2023, 177 (02) : 72 - 80
  • [6] Dynamic coefficients of large-span cable-membrane roof structures
    Li, Jing
    Han, Da-Jian
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2009, 28 (05): : 153 - 159
  • [7] RESEARCH OF STIFFNESS PERFORMANCE OF TRUSS STRING STRUCTURE OF A LARGE-SPAN ROOF STRUCTURE
    Sun, Wen-Bo
    Huang, Wei
    [J]. INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2011, : 989 - 993
  • [8] Design of a single large-span roof structure for Rotterdam Zoo 'Blijdorp'
    Kieboom, S. J. C.
    [J]. TUBULAR STRUCTURES XII, 2009, : 487 - +
  • [10] Study on wind-induced response of a large-span roof by using finite particle method
    Wang, Qinhua
    Liu, Feihong
    Yu, Ying
    [J]. STRUCTURES, 2021, 34 : 3567 - 3582