Wind response control of tall buildings with a tuned mass damper

被引:98
|
作者
Elias, Said [1 ]
Matsagar, Vasant [1 ]
机构
[1] Indian Inst Technol IIT Delhi, Dept Civil Engn, Hauz Khas, New Delhi 110016, India
来源
关键词
Modal frequency/shape; Tuned mass damper (TMD); Tall building; Wind forces; VIBRATION CONTROL; MITIGATION; DESIGN;
D O I
10.1016/j.jobe.2017.11.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind response control of tall buildings installed with a tuned mass damper (TMD) is investigated. The performance of a TMD installed at the topmost floor of a 76-storey benchmark building is compared with the TMD installed at different floors (locations) of the building. The TMD is placed where particular mode shape amplitude of the building is largest or larger. At each location, the performance of the TMD is examined by tuning it to the first few modal frequencies. The coupled differential equations of motion for the building without/with the TMD are derived and solved by employing Newmark's integration method. Variations in the normalized response of the controlled building under wind forces are computed to study the effectiveness of using different TMD schemes. Placement, tuning frequencies, mass and damping ratios of the devices are the parameters investigated to compare the effectiveness of these different TMD schemes. It is concluded that placement of the TMD shows a significant influence in improvement of the performance of the TMD, especially if it is tuned to the corresponding modal frequency. In addition, the optimally determined damping ratio reduces for the TMD tuned to the higher modal frequencies.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 50 条
  • [21] Supertall buildings with tuned mass damper
    Youssef, Nabih
    Structural Design of Tall Buildings, 1994, 3 (01): : 1 - 12
  • [22] Response control of chimneys using tuned mass damper, multi-tuned mass damper and tuned mass inerter system
    Rahman, Saba
    Jain, A. K.
    Jha, K. N.
    Bharti, S. D.
    Datta, T. K.
    STRUCTURES, 2024, 69
  • [23] Effect of tuned mass damper in wind-induced response of "V" plan-shaped tall building
    Bhattacharya, Satadru
    Dalui, Sujit Kumar
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2022, 31 (09):
  • [24] Evaluation of Sloped Bottom Tuned Liquid Damper for Reduction of Seismic Response of Tall Buildings
    Patil G.R.
    Singh K.D.
    Patil, G.R. (p.rajaram@iitg.ac.in), 1600, Springer (97): : 385 - 394
  • [25] Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter (vol 143, 2017)
    Giaralis, Agathoklis
    Petrini, Francesco
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)
  • [26] Optimum design of the tuned mass-damper-inerter for serviceability limit state performance in wind-excited tall buildings
    Giaralis, Agathoklis
    Petrini, Francesco
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1773 - 1778
  • [27] Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper
    Aly, Aly Mousaad
    SMART STRUCTURES AND SYSTEMS, 2014, 13 (03) : 473 - 500
  • [28] LQR control of across-wind responses of tall buildings using composite tuned mass dampers
    Kim, Y. M.
    You, K. P.
    You, J. Y.
    Paek, S. Y.
    Nam, B. H.
    CIVIL, ARCHITECTURE AND ENVIRONMENTAL ENGINEERING, VOLS 1 AND 2, 2017, : 403 - 409
  • [29] Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2022, 10 (08) : 2935 - 2945
  • [30] Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building
    Sameer J Suthar
    Radhey Shyam Jangid
    Journal of Vibration Engineering & Technologies, 2022, 10 : 2935 - 2945