On-orbit installation matrix calibration and its application on AGRI of FY-4A

被引:6
|
作者
Chen, Boyang [1 ]
Li, Xiaoyan [2 ,3 ]
Zhang, Gaoxiong [4 ]
Guo, Qiang [1 ]
Wu, Yapeng [2 ]
Wang, Baoyong [2 ]
Chen, Fansheng [2 ]
机构
[1] Natl Satellite Meteorol Ctr, Beijing, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Tech Phys, Key Lab Intelligent Infrared Percept, Shanghai, Peoples R China
[3] Univ Chinese Acad Sci, Hangzhou Inst Adv Study, Hangzhou, Peoples R China
[4] Shanghai Inst Satellite Engn, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
on-orbit calibration; image navigation; installation matrix; FY-4A; advanced geostationary radiation imager; IMAGE NAVIGATION; GEOSTATIONARY;
D O I
10.1117/1.JRS.14.024507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Image navigation is a primary process for on-orbit optical payloads involving environmental disaster monitoring, meteorological observation, and the positioning and tracking of space-aeronautics targets. However, because they are affected by solar illumination and orbital heat flux, as well as shock and vibration during launch, the installation structures between the instruments and satellite platform, especially for geostationary satellites, will inevitably generate a displacement resulting in the reduction of positioning accuracy. During the application of FengYun-4A (FY-4A), it is found that the further away from the subsatellite point, the greater the positioning error of Advanced Geostationary Radiation Imager (AGRI) on FY-4A will be. The positioning error can reach 14 pixels at the Arabian Peninsula in operational images. In addition, compared with orbital and attitude measurement errors, long-term observations show that the installation matrix is likely to be the most significant factor determining the navigation accuracy of AGRI. Therefore, an on-orbit installation matrix calibration approach as well as a high-precision navigation algorithm is proposed to modify the positioning error of AGRI. Experimental results show that the navigation error of the processed images corrected by the proposed method can be reduced to 1.3 pixels, which greatly improves the navigation procession of AGRI. In general, this method could be a supplement to the correction of positioning error for geostationary payloads. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] An Improved Aerosol Retrieval Algorithm for FY-4A/AGRI Data Based on the GRASP Framework
    Wang, Huaxuan
    Fan, Meng
    Jiao, Sunxin
    Yan, Huanhuan
    Xu, Benben
    Liu, Xu
    Wang, Yang
    Tao, Jinhua
    Chen, Liangfu
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2025, 63
  • [22] Validation of FY-4A AGRI layer precipitable water products using radiosonde data
    Wang, Yizhu
    Liu, Hailei
    Zhang, Yong
    Duan, Minzheng
    Tang, Shihao
    Deng, Xiaobo
    ATMOSPHERIC RESEARCH, 2021, 253
  • [23] On-Orbit Calibration of Installation Matrix between Remote Sensing Camera and Star Camera Based on Vector Angle Invariance
    Tang, Yujie
    Wei, Zhenzhong
    Wei, Xinguo
    Li, Jian
    Wang, Gangyi
    SENSORS, 2020, 20 (19) : 1 - 21
  • [24] FY-4A/AGRI海表温度产品和质量检验
    崔鹏
    王素娟
    陆风
    肖萌
    应用气象学报, 2023, 34 (03) : 257 - 269
  • [25] Comparison of FY-4A/AGRI SST with Himawari-8/AHI and In Situ SST
    Yang, Chang
    Guan, Lei
    Sun, Xiaohui
    REMOTE SENSING, 2023, 15 (17)
  • [26] CACM-Net: Daytime Cloud Mask for AGRI Onboard the FY-4A Satellite
    Yang, Jingyuan
    Qiu, Zhongfeng
    Zhao, Dongzhi
    Song, Biao
    Liu, Jiayu
    Wang, Yu
    Liao, Kuo
    Li, Kailin
    REMOTE SENSING, 2024, 16 (14)
  • [27] On-Orbit Radiometric Calibration Accuracy of FY-3A MERSI Thermal Infrared Channel
    Xu Na
    Hu Xiu-qing
    Chen Lin
    Zhang Yong
    Hu Ju-yang
    Sun Ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (12) : 3429 - 3434
  • [28] FY-3D MERSI On-Orbit Radiometric Calibration from the Lunar View
    Wu, Ronghua
    Zhang, Peng
    Xu, Na
    Hu, Xiuqing
    Chen, Lin
    Zhang, Lu
    Yang, Zhongdong
    SENSORS, 2020, 20 (17) : 1 - 13
  • [29] On-orbit radiometric calibration for water-vapor band of FY-2 satellite
    Guo Qiang
    Chen Bo-Yang
    Yang Chang-Jun
    Feng Xuan
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (06) : 523 - 527
  • [30] On-orbit Absolute Calibration of Temperature with Application to the CLARREO Mission
    Best, Fred A.
    Adler, Douglas P.
    Ellington, Scott D.
    Thielman, Donald J.
    Revercomb, Henry E.
    EARTH OBSERVING SYSTEMS XIII, 2008, 7081