International normalized ratio testing with a point-of-care coagulometer in 1-month-old infants: A comparison with Normotest

被引:4
|
作者
Iijima, Shigeo [1 ]
Baba, Toru [1 ]
Ueno, Daizo [1 ]
Ohishi, Akira [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Pediat, Hamamatsu, Shizuoka, Japan
关键词
VITAMIN-K-DEFICIENCY; PROTHROMBIN PIVKA-II; STANDARDIZATION-SUBCOMMITTEE; ORAL ANTICOAGULATION; COAGULATION-FACTORS; CHILDREN; PROPHYLAXIS; HEMOSTASIS; THERAPY; SYSTEM;
D O I
10.1016/j.thromres.2016.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Early infants are at risk of vitamin K (VK) deficiency-associated bleeding unless they receive VK prophylaxis. A coagulation screening test might be necessary to detect prophylactic failure, but it is rarely conducted owing to the difficulty of blood sampling. CoaguChek XS is a portable, point-of-care (POC) coagulation analyzer that determines international normalized ratios (INRs) using only small volumes of blood. Although POC tests assessing INR have become widespread for adults, studies have not been performed in early infancy. This study aimed to determine the reference interval (RI) for INR for 1-month-old infants using the CoaguChek XS and to compare INRs with Normotest (NT) values to evaluate its efficacy as a VK deficiency screening test. Materials and methods: This study included 578 consecutive 1-month-old, healthy, term infants who underwent a 1-month health checkup. CoaguChek XS INRs and NT values were analyzed for each subject. Results: The enrolled neonates were orally administered VK 6-12 h and 4 days after birth. An INR RI for 1-month old infants was established using the CoaguChek XS (range of 0.9-1.1). On the other hand, the NT RI was 69%-130%. We observed a significant inverse correlation between INRs and NT values. Conclusions: Our study is the first to establish an INR RI using the CoaguChek XS for 1-month-old, healthy, term infants. CoaguChek XS INR was more convenient to test than NT. However, we could not demonstrate its efficacy as a VK deficiency screening test because no infant had an aberrant NT value or a bleeding disorder. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 50 条
  • [41] A Comparison of International Normalized Ratio (INR) Determined by Point-of-Care to Standard Laboratory Testing Before Mohs Micrographic Surgery: A Prospective, Single-Center Study
    Moody, Rylee
    Tinker, Daniel
    Behshad, Ramona
    DERMATOLOGIC SURGERY, 2023, 49 (10) : 967 - 969
  • [42] Differences in warfarin dosing decisions based on international normalized ratio measurements with two point-of-care testing devices and a reference laboratory measurement
    Shermock, KM
    Bragg, L
    Connor, JT
    Fink, J
    Mazzoli, G
    Kottke-Marchant, K
    PHARMACOTHERAPY, 2002, 22 (11): : 1397 - 1404
  • [43] Warfarin Patients With Anemia Show Trend of Out-of-Range International Normalized Ratio Frequency With Point-of-Care Testing in an Anticoagulation Clinic
    DeRemer, Christina E.
    McMichael, Bliss
    Young, Henry N.
    JOURNAL OF PHARMACY PRACTICE, 2019, 32 (05) : 499 - 502
  • [44] International Normalized Ratio (INR) testing: analytical and clinical performance of four point-of-care devices versus central laboratory instrumentation analysis
    Kemna, Erwin
    Jentink, Wilma
    te Molder, Irmgard
    Straalman, Ingeborg
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (03) : E89 - E92
  • [45] Low-molecular-weight heparin may alter point-of-care assay for international normalized ratio
    Phillips, EM
    Buchan, DA
    Newman, N
    Rajan, A
    Zia, S
    PHARMACOTHERAPY, 2005, 25 (10): : 1341 - 1347
  • [46] Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin
    Bauman, Mary E.
    Black, Karina L.
    Massicotte, Mary P.
    Bauman, Michelle L.
    Kuhle, Stefan
    Howlett-Clyne, Susan
    Cembrowski, George S.
    Bajzar, Laszlo
    THROMBOSIS AND HAEMOSTASIS, 2008, 99 (06) : 1097 - 1103
  • [47] Verification of the qLabs international normalized ratio point-of-care device for monitoring of patients attending an anticoagulation clinic
    Mbokota, N.
    Schapkaitz, E.
    Louw, S.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (05) : 508 - 514
  • [48] Comparison of point-of-care testing (POCT): i-STAT® international normalized ratio (INR) vs reference laboratory INR in pediatric patients undergoing major surgery
    Spielmann, Nelly
    Mauch, Jacqueline Y.
    Madjdpour, Caveh
    Schmugge, Markus
    Albisetti, Manuela
    Weiss, Markus
    Haas, Thorsten
    PEDIATRIC ANESTHESIA, 2011, 21 (10) : 1041 - 1045
  • [49] Bias and uncertainty of the International Normalized Ratio determined with a whole blood point-of-care prothrombin time test device by comparison to a new International Standard for thromboplastin
    van den Besselaar, Antonius M. H. P.
    van Rijn, Claudia J. J.
    Abdoel, Charmane F.
    Cobbaert, Christa M.
    THROMBOSIS RESEARCH, 2021, 202 : 1 - 7
  • [50] Comparison of international normalized ratio (INR) from a standard lab test and two point-of-care devices, Protime® (PRT) and Coaguchek® (CC).
    Hei, DL
    Taylor, JR
    Kilroy, RA
    Lopez, LM
    BLOOD, 2000, 96 (11) : 652A - 652A