Application of ultrasonic clamp-on flow meters for in situ tests of billing meters in district heating systems

被引:3
|
作者
Svensson, B [1 ]
Delsing, J [1 ]
机构
[1] Lulea Univ Technol, S-97187 Lulea, Sweden
关键词
flow meters; ultrasonic; Reynolds number; district heating systems;
D O I
10.1016/S0955-5986(98)00007-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Three methods of using ultrasonic flow meters for the purpose of testing small- and medium-sized billing flow meters in district heating subscriber stations in situ were investigated. Four subscriber stations, six billing flow meters, and three ultrasonic clamp-on meters were part of the investigation. The obtained results show that clamp-on meters have measurement accuracy problems on the ordinary steel piping in the subscriber stations. When using well defined pipes mounted in series with the billing flow meters the results are clearly better; provided that the flow rates exceed a Reynolds number of approximately 10 000. Ln this flow region, billing flow meter deviations > +/- 5% can be detected. A flow rate below this Reynolds number renders the method less reliable. The useful flow range is extended when using calibration data from the clamp-on meter to correct the measured data, making it possible to determine deviations > +/- 10% in flow rates below a Reynolds number of 10 000. The investigation also showed that not all clamp-on meters are suited for this type of in situ test. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 10 条
  • [1] Mathematical modelling of ultrasonic flow meters with clamp-on transducers
    Willatzen, A
    [J]. ACTA ACUSTICA UNITED WITH ACUSTICA, 2004, 90 (01) : 70 - 76
  • [2] Field verification of thermal energy meters through ultrasonic clamp-on master meters
    Ficco, G.
    Frattolillo, A.
    Malengo, A.
    Puglisi, G.
    Saba, F.
    Zuena, F.
    [J]. MEASUREMENT, 2020, 151
  • [3] The uncertainties induced by internal pipe wall roughness on the measurements of clamp-on ultrasonic flow meters
    Gu, Xiaotang
    Cegla, Frederic
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1586 - 1589
  • [4] Industrial experiences show clamp-on ultrasonic transit time flow meters assumptions lead to erroneous measurement results
    Ton, V.
    [J]. RESULTS IN ENGINEERING, 2022, 15
  • [5] Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
    Massaad, Jack
    van Neer, Paul L. M. J.
    van Willigen, Douwe M.
    Pertijs, Michiel A. P.
    de Jong, Nicolaas
    Verweij, Martin D.
    [J]. SENSORS, 2022, 22 (14)
  • [6] ULTRASONIC FLOW METERS . DEVELOPMENT AND EXPERIMENTAL APPLICATION
    PERONNEAU, P
    DELOCHE, A
    HUNG, BM
    HINGLAIS, J
    [J]. EUROPEAN SURGICAL RESEARCH, 1969, 1 (02) : 147 - +
  • [7] APPLICATION OF CLAMP-ON ULTRASONIC FLOWMETER FOR INDUSTRIAL FLOW MEASUREMENTS
    SZEBESZCZYK, JM
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (02) : 127 - 131
  • [8] Experience in the application of single-beam ultrasonic flow meters for turbines
    Krasilnikov A.M.
    Dmitriev S.G.
    Karyakin V.A.
    [J]. Power Technology and Engineering, 2002, 36 (2) : 96 - 98
  • [9] An intelligent approach for calculating natural gas compressibility factor and its application in ultrasonic flow meters
    Farzaneh-Gord, Mahmood
    Rahbari, Hamid Reza
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2020, 76
  • [10] Enabling Alarm-Based Fault Prediction for Smart Meters in District Heating Systems: A Danish Case Study
    Sondergaard, Henrik Alexander Nissen
    Shaker, Hamid Reza
    Jorgensen, Bo Norregaard
    [J]. SMART CITIES, 2024, 7 (03): : 1126 - 1148