APPLICATION OF CLAMP-ON ULTRASONIC FLOWMETER FOR INDUSTRIAL FLOW MEASUREMENTS

被引:7
|
作者
SZEBESZCZYK, JM
机构
[1] Silesian University of Technology, Department of Automatic Control, Electronics and Computer Science, Gliwice
关键词
ULTRASONIC FLOWMETER; CLAMP-ON TRANSDUCERS; TRANSIT TIME;
D O I
10.1016/0955-5986(94)90047-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The development and testing results of a newly designed clamp-on transit time ultrasonic flowmeter are presented. The microprocessor-based flowmeter was tested on steel pipelines of diameters ranging from 40 mm to 300 mm in some water plants and in the calibration station. The results of calibration have proved that the nonlinearity error of flowmeter is less than 1%.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [1] Clamp-on ultrasonic flowmeter for gases
    不详
    [J]. HYDROCARBON PROCESSING, 2001, 80 (10): : 30 - 30
  • [2] APPLICATION OF A PORTABLE CLAMP-ON ULTRASONIC FLOWMETER IN THE WATER INDUSTRY
    CASCETTA, F
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (03) : 191 - 194
  • [3] Versatile clamp-on Doppler ultrasonic flowmeter
    不详
    [J]. HYDROCARBON PROCESSING, 2006, 85 (03): : 26 - 26
  • [4] Easy-setup clamp-on ultrasonic flowmeter
    Terao, Minako
    Tanaka, Hiroaki
    Tanaka, Yoshiaki
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [5] HIGH-TEMPERATURE CLAMP-ON ULTRASONIC FLOWMETER
    NGUYEN, TH
    LYNNWORTH, LC
    RUNDE, HA
    MERILLO, M
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 214 - 214
  • [6] Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter
    Murakawa, Hideki
    Ichimura, Shuhei
    Shimada, Masaki
    Sugimoto, Katsumi
    Asano, Hitoshi
    Umezawa, Shuichi
    Sugita, Katsuhiko
    [J]. MECHANICAL ENGINEERING JOURNAL, 2020, 7 (04):
  • [7] Ultrasonic Transducer Positioning System for Clamp-on Flowmeter Applications
    Bailleu, Anett
    [J]. 2016 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2016) PROCEEDINGS, 2016, : 122 - 127
  • [8] Clamp-on ultrasonic flowmeter data interface to SCADA host
    Douglass, SA
    [J]. ENTELEC '96, TECHNICAL PAPERS: TO EDUCATE AND INFORM, 1996, : 1 - 3
  • [9] Feasibility Study on Clamp-on Ultrasonic Flowmeter Based on EMAT
    Ji, Bonggyu
    Park, Jae-Ha
    Cho, Seung Hyun
    [J]. JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2018, 38 (05) : 316 - 321
  • [10] Clamp-on submersible flowmeter
    不详
    [J]. HYDROCARBON PROCESSING, 1996, 75 (01): : 40 - 40