Mass-selective operation with REXTRAP

被引:11
|
作者
Gustafsson, A. [1 ]
Herlert, A. [1 ]
Wenander, F. [2 ]
机构
[1] CERN, Dept Phys, CH-1211 Geneva 23, Switzerland
[2] CERN, Beams Dept, CH-1211 Geneva 23, Switzerland
关键词
REX-ISOLDE; Mass selection; Penning trap; Mass separation; Space-charge; RADIOACTIVE ION-BEAM; PENNING TRAP; SPECTROMETRY; PURIFICATION; ISOTOPES; FACILITY;
D O I
10.1016/j.nima.2010.10.004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the radioactive ion-beam facility REX-ISOLDE more than 60 different types of radionuclide ions have been post-accelerated to energies up to 3.15 MeV/u within the last years. The transmission efficiency of the system has continually increased with gained operation experience. Apart from striving for the highest possible intensity, the beam purity is also of crucial importance for many experiments. For this reason isobaric contaminant suppression in the low energy stage of REX-ISOLDE has been investigated. Until now the Penning trap system REXTRAP was used solely as a device for bunching the incoming quasi-continuous radioactive ion-beam from ISOLDE and reducing the emittance for efficient injection into the REXEBIS charge breeder. The possibility of operating REXTRAP in a mass-resolving mode and injecting bunched beams from the recently installed radiofrequency quadrupole cooler and buncher ISCOOL has been studied in detail. Results related to transmission efficiency,achieved mass-resolving power, and limitations due to space-charge effects are presented. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [21] MASS-SELECTIVE TRAPPING OF PULSED CHARGED-PARTICLE BEAMS
    O, CS
    SCHUESSLER, HA
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 27 (03): : 129 - 135
  • [22] Integration of continuous-flow accelerator mass spectrometry with chromatography and mass-selective detection
    Flarakos, Jimmy
    Liberman, Rosa G.
    Tannenbaum, Steven R.
    Skipper, Paul L.
    ANALYTICAL CHEMISTRY, 2008, 80 (13) : 5079 - 5085
  • [23] MODERN GENERAL-UNKNOWN ANALYSIS USING A MASS-SELECTIVE DETECTOR
    MAURER, H
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1987, 25 (09): : 619 - 619
  • [24] HIGH-SENSITIVITY DETERMINATION OF NADOLOL IN PLASMA WITH MASS-SELECTIVE DETECTION
    DELBEKE, FT
    DEBACKERE, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 416 (02): : 443 - 444
  • [25] Mass-selective lipase-catalyzed poly(ε-caprolactone) transesterification reactions
    Bankova, M
    Kumar, A
    Impallomeni, G
    Ballistreri, A
    Gross, RA
    MACROMOLECULES, 2002, 35 (18) : 6858 - 6866
  • [26] Storage and mass-selective control of ions in an electrostatic ion storage ring
    Jinno, S.
    Takao, T.
    Hanada, K.
    Goto, M.
    Okuno, K.
    Tanuma, H.
    Azuma, T.
    Shiromaru, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 568 - 579
  • [27] MULTIPHOTON EXCITATION AND MASS-SELECTIVE ION DETECTION FOR NEUTRAL AND ION SPECTROSCOPY
    BOESL, U
    JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (08): : 2949 - 2962
  • [28] AUTOMATED THEOPHYLLINE ASSAY USING GAS-CHROMATOGRAPHY AND A MASS-SELECTIVE DETECTOR
    DESAGE, M
    SOUBEYRAND, J
    SOUN, A
    BRAZIER, JL
    GEORGES, Y
    JOURNAL OF CHROMATOGRAPHY, 1984, 336 (02): : 285 - 291
  • [29] MASS-SELECTIVE ISOLATION OF IONS STORED IN A QUADRUPOLE ION TRAP - A SIMULATION STUDY
    MARCH, RE
    LONDRY, FA
    ALFRED, RL
    FRANKLIN, AM
    TODD, JFJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3): : 247 - 271
  • [30] (CLINICAL) TOXICOLOGICAL DETECTION OF ANTIHISTAMINES AND THEIR METABOLITES IN URINE USING A MASS-SELECTIVE DETECTOR
    MAURER, H
    WEBER, A
    PFLEGER, K
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1987, 25 (09): : 620 - 620