Mass-selective operation with REXTRAP

被引:11
|
作者
Gustafsson, A. [1 ]
Herlert, A. [1 ]
Wenander, F. [2 ]
机构
[1] CERN, Dept Phys, CH-1211 Geneva 23, Switzerland
[2] CERN, Beams Dept, CH-1211 Geneva 23, Switzerland
关键词
REX-ISOLDE; Mass selection; Penning trap; Mass separation; Space-charge; RADIOACTIVE ION-BEAM; PENNING TRAP; SPECTROMETRY; PURIFICATION; ISOTOPES; FACILITY;
D O I
10.1016/j.nima.2010.10.004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the radioactive ion-beam facility REX-ISOLDE more than 60 different types of radionuclide ions have been post-accelerated to energies up to 3.15 MeV/u within the last years. The transmission efficiency of the system has continually increased with gained operation experience. Apart from striving for the highest possible intensity, the beam purity is also of crucial importance for many experiments. For this reason isobaric contaminant suppression in the low energy stage of REX-ISOLDE has been investigated. Until now the Penning trap system REXTRAP was used solely as a device for bunching the incoming quasi-continuous radioactive ion-beam from ISOLDE and reducing the emittance for efficient injection into the REXEBIS charge breeder. The possibility of operating REXTRAP in a mass-resolving mode and injecting bunched beams from the recently installed radiofrequency quadrupole cooler and buncher ISCOOL has been studied in detail. Results related to transmission efficiency,achieved mass-resolving power, and limitations due to space-charge effects are presented. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [1] Operation and Performance of a Mass-Selective Cryogenic Linear Ion Trap
    Tesler, Larry F.
    Cismesia, Adam P.
    Bell, Matthew R.
    Bailey, Laura S.
    Polfer, Nicolas C.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (11) : 2115 - 2124
  • [2] Mass-selective laser photoionization
    Small, RE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 279 - COMP
  • [3] Mass-Selective Chiral Analysis
    Boesl, Ulrich
    Kartouzian, Aras
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 9, 2016, 9 : 343 - 364
  • [4] Mass spectrometry and mass-selective detection in chromatography
    Vékey, K
    JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (02) : 227 - 236
  • [5] THE MASS-SELECTIVE DETECTOR AS A CHLORINE-SELECTIVE DETECTOR
    JOHNSEN, S
    KOLSET, K
    JOURNAL OF CHROMATOGRAPHY, 1988, 438 (02): : 233 - 242
  • [6] MASS-SELECTIVE MULTICOLOR LASER SPECTROSCOPY
    SMALLEY, RE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 59 - PHYS
  • [7] Mass-selective Neutron Spectroscopy Beyond the Proton
    Krzystyniak, M.
    Seel, A. G.
    Richards, S. E.
    Gutmann, M. J.
    Fernandez-Alonso, F.
    VI WORKSHOP IN ELECTRON VOLT NEUTRON SPECTROSCOPY: FRONTIERS AND HORIZONS, 2014, 571
  • [8] Ion trap for mass-selective production of nanoclusters
    Kanayama, T
    Murakami, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1997, 15 (06): : 2882 - 2886
  • [9] NEW MASS-SELECTIVE EVAPORATION RATE MONITOR
    GENEQUAN.P
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1974, 11 (01): : 357 - 360
  • [10] INVESTIGATION ON THE QUANTIFICATION OF PESTICIDES WITH MASS-SELECTIVE DETECTORS
    JOBST, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (04): : 298 - 300