Evaluating the different boundary conditions to simulate airflow and heat transfer in Double-Skin Facade

被引:0
|
作者
Ahmadi, Javad [1 ]
Mahdavinejad, Mohammadjavad [1 ]
Larsen, Olena Kalyanova [2 ]
Zhang, Chen [2 ]
Zarkesh, Afsaneh [1 ]
Asadi, Somayeh [3 ]
机构
[1] Tarbiat Modares Univ, Dept Architecture, Highperformance Architecture Lab, Jalal E Al Ahmad Highway, Tehran, Iran
[2] Aalborg Univ, Fac Engn & Sci, Dept Built Environm, Div Architectural Engn, Aalborg, Denmark
[3] Penn State Univ, Dept Architectural Engn, State Coll, PA 16801 USA
关键词
Double-Skin Facade; boundary conditions; thermal performance; airflow; irradiation; TURBULENT NATURAL-CONVECTION; ENERGY PERFORMANCE; CHANNEL; VENTILATION; CAVITIES; BEHAVIOR;
D O I
10.1007/s12273-021-0824-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
The CFD simulation accuracy mostly depends on the appropriate setting of boundary conditions and numerical simulation parameters. This study shows the influence of two types of boundary condition settings on the CFD simulation results of Double-Skin Facade (DSF) for a specific problem. These two boundary settings are the constant temperature on the DSF surfaces called Boundary A, and Boundary B is defined via solar radiation using the Discrete Ordinate radiation Model (DOM). The paper verified both the numerical simulations using the experimental data. Comparing the numerical results of two types of boundaries with experimental data shows that both cases underestimated the values lower than 5.2 K and 0.1 m/s for the temperature and velocity respectively at the regarded measured points. Boundary A gives more accurate temperature prediction results, while Boundary B shows velocity magnitude closer to the measurements in the middle height of the cavity; the average temperature and velocity differences between the two boundary types are 0.6 K and 0.003 m/s respectively which are negligible. Finally, the selection of boundary conditions depends on study purposes, however, when the DSF is equipped with blinds and if there is not enough data in hand but the exact value of solar irradiation, using the Boundary B approach is suggested; it can provide reasonable results associated with multi-type of thermal boundary conditions at the same time. Furthermore, if the goal is to investigate the flow pattern in the DSF, Boundary B is argued to perform better than the constant temperature boundary condition.
引用
收藏
页码:799 / 815
页数:17
相关论文
共 50 条
  • [21] Thermal behaviour and efficiency of ventilated double-skin facade in Polish climatic conditions
    Heim, D.
    Janicki, M.
    [J]. RESEARCH ON BUILDING PHYSICS, 2010, : 257 - 263
  • [22] Heat transfer coefficients of double skin facade windows
    Zhu, Jiayi
    He, Guoqing
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (09) : 1143 - 1151
  • [23] Naturally ventilated double-skin facade in modeling and experiments
    Dama, Alessandro
    Angeli, Diego
    Larsen, Olena Kalyanova
    [J]. ENERGY AND BUILDINGS, 2017, 144 : 17 - 29
  • [24] Research on Built Environmental Characteristics of Double-Skin Facade
    Zhang, Weijie
    Li, Yanyan
    Gao, Dongyuan
    Zhao, Qianqian
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 435 - 451
  • [25] Naturally ventilated double-skin facade with adjustable louvers
    Tao, Yao
    Fang, Xiang
    Setunge, Sujeeva
    Tu, Jiyuan
    Liu, Jingcheng
    Shi, Long
    [J]. SOLAR ENERGY, 2021, 225 : 33 - 43
  • [26] A thermal similarity model of a curved double-skin facade
    Huang, Yi
    Tao, Yao
    Shi, Long
    Liu, Qinggong
    Wang, Yong
    Tu, Jiyuan
    Gan, Xin
    [J]. SOLAR ENERGY, 2023, 262
  • [27] SPREAD OF SMOKE AND HEAT ALONG NARROW AIR CAVITY IN DOUBLE-SKIN FACADE FIRES
    Chow, Cheuk Lun
    [J]. THERMAL SCIENCE, 2014, 18 : S405 - S416
  • [28] Apron design for protecting double-skin facade fires
    Chow, Nadia C. L.
    Li, S. S.
    Huang, D. X.
    [J]. FIRE AND MATERIALS, 2015, 39 (03) : 189 - 206
  • [29] Daylighting characterstics of existing double-skin facade office buildings
    Shameri, M. A.
    Alghoul, M. A.
    Elayeb, OmKalthum
    Zain, M. Fauzi M.
    Alrubaih, M. S.
    Amir, Halizawati
    Sopian, K.
    [J]. ENERGY AND BUILDINGS, 2013, 59 : 279 - 286
  • [30] Effect of cavity depth on smoke spreading of double-skin facade
    Chow, WK
    Hung, WY
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (07) : 970 - 979