Usefulness of the Right Parasternal Echocardiographic View to Improve the Hemodynamic Assessment After Valve Replacement for Aortic Stenosis

被引:4
|
作者
Benfari, Giovanni [1 ]
Nistri, Stefano [2 ]
Cerrito, Luca F. [1 ]
Maritan, Luca [1 ]
Tafciu, Elvin [1 ]
Setti, Martina [1 ]
Bursi, Francesca [3 ]
Tadiello, Enrico [1 ]
De Manna, Nunzio Davide [4 ]
Rossi, Andrea [1 ]
Ribichini, Flavio L. [1 ]
机构
[1] Univ Verona, Div Cardiol, Verona, Italy
[2] CMS Veneto Med, Vicenza, Italy
[3] Univ Milan, ASST Santi Paolo & Carlo, San Paolo Hosp, Div Cardiol,Heart & Lung Dept, Milan, Italy
[4] Univ Verona, Div Cardiac Surg, Verona, Italy
来源
关键词
EUROPEAN ASSOCIATION; AMERICAN SOCIETY; TASK-FORCE; GUIDELINES; SEVERITY; RECOMMENDATIONS; CARDIOLOGY;
D O I
10.1016/j.amjcard.2020.11.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Right-parasternal-view (RPV) often provides the best hemodynamic assessment of the aortic-valve-stenosis by echocardiography. However, no detailed study on patients with aortic prosthesis is available. Thus, RPV usefulness is left as an anecdotical notion in this context. We aimed to define feasibility and clinical-impact of RPV before and soon-after percutaneous implantation (TAVI) or surgical (SAVR) aortic-valve-replacement (AVR) for AS. Patients with severe-AS electively referred for AVR between September-2019 and February-2020 were prospectively evaluated. Echocardiographic examinations inclusive of apical and RPV to measure aortic-peak-velocity, gradients and area (AVA) were performed the day before AVR and at hospital discharge and compared by matched-pair-analysis. Forty-seven patients (mean age 79 +/- 8 years, 63% female, ejection-fraction 61 +/- 6%) referred for SAVR (24 [51%]) or TAVI (23 [49%]) were enrolled. RPV was feasible in 45 patients (96%) before-AVR but in only 32 after-AVR (68%), particularly after SAVR (50%) than TAVI (87% p = 0.005). RPV remained the best acoustic window after TAVI in 75% of cases. Hemodynamic assessment of TAVI, but not SAVR, invariably benefit from RPV versus apical evaluation (aortic-peak-velocity: 2.57 +/- 0.39 vs 2.23 +/- 0.47 m/sec, p = 0.002; mean gradient: 15 +/- 5 vs 12 5 mm Hg, p = 0.01). Five (11%) patients presented severe patient-prosthesis-mismatch, 4 of which were detectable only by RPV. This pilot-experience demonstrates that RPV feasibility is slightly reduced after AVR. RPV can improve the hemodynamic assessment of the prosthetic valve versus apical view, including the detection of patient-prosthesis-mismatch. Furthermore, when RPV is the best acoustic windows in patients with severe AS, it generally remains so after-TAVI. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [21] Echocardiographic Predictor for Persistent Functional/Ischemic Mitral Regurgitation After Aortic Valve Replacement in Patients With Aortic Valve Stenosis
    Matsumura, Yoshiki
    Gillinov, A. Marc
    Toyono, Manatomo
    Yamano, Tetsuhiro
    Takasaki, Kunitsugu
    Saraiva, Roberto M.
    Shiota, Takahiro
    CIRCULATION, 2008, 118 (18) : S859 - S859
  • [22] HEMODYNAMIC AFTER AORTIC-VALVE REPLACEMENT
    KREYMANN, G
    JAKOBS, G
    POLONIUS, M
    RODIGER, W
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 231 - 231
  • [23] Two surgical cases of right parasternal minimal incision for aortic valve replacement
    Tsujii E.
    Kobayashi A.
    Takeuchi T.
    Fukuoka S.
    Murata S.
    Miki S.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (2): : 243 - 247
  • [24] Novel Hemodynamic Index for the Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    Bugan, Baris
    Kapadia, Samir
    Svensson, Lars
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B34 - B34
  • [25] Organised right ventricular remodelling in aortic stenosis even after valve replacement
    Calcutteea, Avin
    Holmgren, Anders
    Lindqvist, Per
    Henein, Michael Y.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1549 - 1550
  • [26] ECHOCARDIOGRAPHIC ASSESSMENT OF SEVERITY OF AORTIC-VALVE STENOSIS
    RESTIEAUX, NJ
    CHRISTIE, H
    NEW ZEALAND MEDICAL JOURNAL, 1985, 98 (789) : 911 - 911
  • [27] Novel hemodynamic index for assessment of aortic regurgitation after transcatheter aortic valve replacement
    Bugan, Baris
    Kapadia, Samir
    Svensson, Lars
    Krishnaswamy, Amar
    Tuzcu, Emin Murat
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (03) : E174 - E179
  • [28] Impact of Aortic Valve Replacement According to Echocardiographic Markers of Aortic Stenosis Severity
    Berthelot-Richer, Maxime
    Pibarot, Philippe
    Capoulade, Romain
    Dumesnil, Jean G.
    Dahou, Abdelaziz
    Le Ven, Florent
    Thebault, Christophe
    Clavel, Marie-Annick
    CARDIOLOGY, 2014, 128 (02) : 119 - 120
  • [29] ECHOCARDIOGRAPHIC PREDICTORS OF OUTCOMES FOLLOWING AORTIC VALVE REPLACEMENT FOR SEVERE AORTIC STENOSIS
    Pacheco, C.
    Stevens, L.
    Tournoux, F.
    Gravel, G. Marquis
    Noiseux, N.
    Mansour, S.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S208 - S208
  • [30] A kinked aortic tube graft after aortic root replacement causes heart failure: usefulness of the right parasternal approach on echocardiography
    Kotaro Numaguchi
    Shinsaku Hatake
    Tomohiro Ueda
    Yukihiro Tomita
    Journal of Medical Ultrasonics, 2015, 42 : 291 - 292