Measurement of cerebral perfusion territories using arterial spin labelling

被引:30
|
作者
Paiva, Fernando F.
Tannus, Alberto
Silva, Afonso C.
机构
[1] NIH, Natl Inst Neurol Disorders & Stroke, Lab Funct & Mol Imaging, Cerebral Microcirculat Unit, Bethesda, MD 20892 USA
[2] Univ Sao Paulo, Inst Phys Sao Carlos, Lab Magnet Resonance Imaging, BR-13560970 Sao Carlos, SP, Brazil
关键词
brain; cerebral blood flow; cerebrovascular diseases; MRI; vascular territory;
D O I
10.1002/nbm.1177
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The ability to assess the perfusion territories of major cerebral arteries can be a valuable asset to the diagnosis of a number of cerebrovascular diseases. Recently, several arterial spin labeling (ASL) techniques have been proposed for determining the cerebral perfusion territories of individual arteries by three different approaches: (1) using a dedicated labeling radio frequency (RF) coil; (2) applying selective inversion of spatially confined areas; (3) employing multidimensional RF pulses. Methods that use a separate labeling RF coil have high signal-to-noise ratio (SNR), low RF power deposition, and unrestricted three-dimensional coverage, but are mostly limited to separation of the left and right circulation, and do require extra hardware, which may limit their implementation in clinical systems. Alternatively, methods that utilize selective inversion have higher flexibility of implementation and higher arterial selectivity, but suffer from imaging artifacts resulting from interference between the labeling slab and the volume of interest. The goal of this review is to provide the reader with a critical survey of the different ASL approaches proposed to date for determining cerebral perfusion territories, by discussing the relative advantages and disadvantages of each technique, so as to serve as a guide for future refinement of this promising methodology. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:633 / 642
页数:10
相关论文
共 50 条
  • [21] Trial of the cerebral perfusion response to sodium nitrite infusion in patients with acute subarachnoid haemorrhage using arterial spin labelling MRI
    Ezra, Martyn
    Franko, Edit
    Spronk, Desiree B.
    Lamb, Catherine
    Okell, Thomas W.
    Pattinson, Kyle TS.
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2024, 153 : 50 - 60
  • [22] Localizing epileptic networks in tuberous sclerosis using arterial spin labelling MRI perfusion
    Azarion, A.
    Davis, K. A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2012, 19 : 235 - 235
  • [23] ARTERIAL SPIN LABELLING PERFUSION MRI IN EPILEPSY SURGERY EVALUATION
    Stockwell, L. J.
    Stone, A.
    Murphy, K.
    Hobden, P.
    Wise, R.
    Hamandi, K.
    EPILEPSIA, 2013, 54 : 209 - 210
  • [24] Cerebral Perfusion Measurements in Elderly with Hypertension Using Arterial Spin Labeling
    Mutsaerts, H. J. M. M.
    van Dalen, J. W.
    Heijtel, D. F. R.
    Groot, P. F. C.
    Majoie, C. B. L. M.
    Petersen, E. T.
    Richard, E.
    Nederveen, A. J.
    PLOS ONE, 2015, 10 (08):
  • [25] Arterial Spin Labelling Cerebral Perfusion Measurements Demonstrate Normal Blood Flow in Subacute Intracerebral Hemorrhage Patients
    Klahr, Ana C.
    Dowlatshahi, Dariush
    Buck, Brian
    Gioia, Laura
    Kalashyan, Hayrapet
    Wilman, Alan
    Jeerakathil, Thomas
    Emery, Derek
    Butcher, Kenneth
    STROKE, 2018, 49
  • [26] Perioperative Assessment of Cerebral Perfusion Territories Through Arterial Spin Labeling Magnetic Resonance Imaging in Carotid Stenosis
    Hosoda, Kohkichi
    Yamamoto, Daisuke
    Uchihashi, Yoshito
    Tanaka, Jun
    Yamamoto, Yusuke
    Kohta, Masaaki
    Fujita, Atsushi
    Sasayama, Takashi
    Kohmura, Eji
    STROKE, 2017, 48
  • [27] Robust estimation of the cerebral blood flow in arterial spin labelling
    Maumet, Camille
    Maurel, Pierre
    Ferre, Jean-Christophe
    Barillot, Christian
    MAGNETIC RESONANCE IMAGING, 2014, 32 (05) : 497 - 504
  • [28] Arterial spin labelling perfusion MRI of breast cancer using FAIR TrueFISP: Initial results
    Buchbender, S.
    Obenauer, S.
    Mohrmann, S.
    Martirosian, P.
    Buchbender, C.
    Miese, F. R.
    Wittsack, H. J.
    Miekley, M.
    Antoch, G.
    Lanzman, R. S.
    CLINICAL RADIOLOGY, 2013, 68 (03) : E123 - E127
  • [29] Dynamic observation of pulmonary perfusion using continuous arterial spin-labelling in a pig model
    Roberts, DA
    Rizi, RR
    Lipson, DA
    Ferrante, MA
    Bearn, L
    Rolf, L
    Baumgardner, J
    Yamomoto, A
    Hatabu, H
    Hansen-Flaschen, J
    Gefter, WB
    Schnall, MD
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (02) : 175 - 180
  • [30] Loss of labelling efficiency caused by carotid stent in pseudocontinuous arterial spin labelling perfusion study
    Chen, D. Y. -T.
    Kuo, Y. -S.
    Hsu, H. -L.
    Yan, F. -X.
    Liu, H. -L.
    Chen, C. -J.
    Tseng, Y. -C.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E21 - E27