Experimental investigation in nucleate pool boiling of binary refrigerant mixtures

被引:10
|
作者
Zhao, Y. H. [1 ]
Diao, Y. H.
Tsuruta, Takaharu
机构
[1] Univ Sci & Technol Beijing, Coll Architecture & Civil Engn, Beijing 100022, Peoples R China
[2] Kyushu Inst Technol, Dept Mech Engn, Kitakyushu, Fukuoka 8048550, Japan
关键词
pool boiling heat transfer; nucleate pool boiling; refrigerant mixture; binary mixture; HFC-134a; HFC-32; HFC-125;
D O I
10.1016/j.applthermaleng.2007.03.035
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer coefficients in nucleate pool boiling for refrigerants under saturated conditions at 0.9 MPa were measured on a horizontal copper surface, Those refrigerants were the pure components of HFC-134a, HFC-32, HFC-125 and two kinds of binary mixtures: nonazeotrope mixture HFC-32/134a, azeotrope mixture HFC-32/125 compared to pure components, both binary mixtures showed lower heat transfer coefficients. This deterioration was more pronounced as heat flux was increased. Experimental data were compared with some empirical and semi-empirical correlations available in literature. For binary mixtures, the accuracy of those correlations varied considerably with mixtures and heat flux. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 115
页数:6