Iatrogenic metacarpal fracture after K-wire fixation: A case report and prevention

被引:1
|
作者
Gu, Ja Hea [1 ]
Choi, Su Hyun [1 ]
机构
[1] Dankook Univ Hosp, Dept Plast Surg, Cheonan, Chungnam, South Korea
关键词
Iatrogenic fracture; K-wire fixation; CMC subluxation; Metacarpal base fracture; Complication; Case report; COMPLICATIONS;
D O I
10.1016/j.ijscr.2019.11.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
INTRODUCTION: Iatrogenic fractures after failed K-wire fixation in the management of a carpometacarpal (CMC) joint fracture-dislocation have not yet been reported (Hsu et al., 2011). We present a case of K-wire-related complication in the management of a CMC joint fracture-dislocation and highlight the importance of planning K-wire placement and minimizing the number of K-wire passes. PRESENTATION OF CASE: After beating his hand against a wall, a 22-year-old patient visited our clinic complaining of a swollen and painful wrist. Following our protocol, reduction and K-wire fixation was planned. During these procedures, the resident of our team made several attempts to insert transfixation pins and radiologic finding demonstrated incorrect placement of the K-wire track. The patient visited the outpatient clinic at 5 weeks postoperatively then we removed the K-wires and began mobilization. Two weeks later, the patient came back with acute onset of pain and swelling at the 5th metacarpal area. DISCUSSION: Stahl and Schwartz reported that 27.8 % of complications related K-wire were due to technical failure and 90 % of technical failure were caused by hospital residents. Well-established guidelines and supervision by a highly experienced surgeon is likely to reduce the rate of technical failure. Multiple passes of the K-wire have resulted in blunting of the K-wire and subsequent heat generation then lead to subsequent loosening and loss of fixation. CONCLUSION: Preoperative planning, marking the K-wire route, and appropriate K-wire thickness minimize such complications. Patients should be informed that following K-wire removal, the residual holes could be subject to stress risers. (C) 2019 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 50 条
  • [21] Intramedullary fixation of metacarpal and phalangeal bone fractures with bioabsorbable Mg K-wire in 20 cases
    Lee, Bong-Ju
    Lee, Chul-Hyung
    Lee, Young-Ho
    Woo, Seungha
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (07): : 2911 - 2920
  • [22] Intramedullary fixation of metacarpal and phalangeal bone fractures with bioabsorbable Mg K-wire in 20 cases
    Bong-Ju Lee
    Chul-Hyung Lee
    Young-Ho Lee
    Seungha Woo
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 2911 - 2920
  • [23] Biomechanical Comparison of 2 Methods of Intramedullary K-Wire Fixation of Transverse Metacarpal Shaft Fractures
    Hiatt, Stephen V.
    Begonia, Mark T.
    Thiagarajan, Ganesh
    Hutchison, Richard L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (08): : 1586 - 1590
  • [24] NON-UNION OF ISOLATED RADIAL NECK FRACTURE USING A BONE GRAFT AND TEMPORARY K-WIRE FIXATION: A CASE REPORT
    Cha, Soo-Min
    Shin, Hyun-Dae
    Kim, Kyung-Cheon
    Song, Jae-Hwang
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2013, 18 (03): : 389 - 392
  • [25] Delayed Migration of Fractured K-wire Causing Vertebral Artery Invagination After Anterior Atlantoaxial Fixation: A Case Report
    Hafez, Ahmad
    Ibrahim, Tarik F.
    Raj, Rahul
    Antinheimo, Jussi
    Siironen, Jari
    Hernesniemi, Juha
    WORLD NEUROSURGERY, 2016, 88 : 695.e5 - 695.e10
  • [26] Adult tibial eminence fracture fixation: arthroscopic procedure using K-wire folded fixation
    Nicolas Bonin
    Laurent Jeunet
    Laurent Obert
    David Dejour
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 857 - 862
  • [27] Adult tibial eminence fracture fixation: arthroscopic procedure using K-wire folded fixation
    Bonin, Nicolas
    Jeunet, Laurent
    Obert, Laurent
    Dejour, David
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (07) : 857 - 862
  • [28] Tibial avulsion fracture of the posterior cruciate ligament: K-wire or screw fixation?
    Seitz H.
    Schlenz I.
    Pajenda G.
    Vécsei V.
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 (5) : 275 - 278
  • [29] Prospective Comparison of the Early Outcomes of Headless Compression Screw and Percutaneous K-Wire Fixation in Metacarpal Fractures
    Supichyangur, Kittiwan
    Tananon, Tanaphat
    Sripakdee, Saeng-Artit
    Chunyawongsak, Veeranon
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (09): : 950.e1 - 950.e9
  • [30] Comparison of Miniplate and K-wire in the Treatment of Metacarpal and Phalangeal Fractures
    Ahmed, Zulfiqar
    Haider, Muhammad Imran
    Buzdar, M. Iqbal
    Chugtai, Babar Bakht
    Rashid, Majid
    Hussain, Nazar
    Ali, Farman
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)