Iatrogenic metacarpal fracture after K-wire fixation: A case report and prevention

被引:1
|
作者
Gu, Ja Hea [1 ]
Choi, Su Hyun [1 ]
机构
[1] Dankook Univ Hosp, Dept Plast Surg, Cheonan, Chungnam, South Korea
关键词
Iatrogenic fracture; K-wire fixation; CMC subluxation; Metacarpal base fracture; Complication; Case report; COMPLICATIONS;
D O I
10.1016/j.ijscr.2019.11.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
INTRODUCTION: Iatrogenic fractures after failed K-wire fixation in the management of a carpometacarpal (CMC) joint fracture-dislocation have not yet been reported (Hsu et al., 2011). We present a case of K-wire-related complication in the management of a CMC joint fracture-dislocation and highlight the importance of planning K-wire placement and minimizing the number of K-wire passes. PRESENTATION OF CASE: After beating his hand against a wall, a 22-year-old patient visited our clinic complaining of a swollen and painful wrist. Following our protocol, reduction and K-wire fixation was planned. During these procedures, the resident of our team made several attempts to insert transfixation pins and radiologic finding demonstrated incorrect placement of the K-wire track. The patient visited the outpatient clinic at 5 weeks postoperatively then we removed the K-wires and began mobilization. Two weeks later, the patient came back with acute onset of pain and swelling at the 5th metacarpal area. DISCUSSION: Stahl and Schwartz reported that 27.8 % of complications related K-wire were due to technical failure and 90 % of technical failure were caused by hospital residents. Well-established guidelines and supervision by a highly experienced surgeon is likely to reduce the rate of technical failure. Multiple passes of the K-wire have resulted in blunting of the K-wire and subsequent heat generation then lead to subsequent loosening and loss of fixation. CONCLUSION: Preoperative planning, marking the K-wire route, and appropriate K-wire thickness minimize such complications. Patients should be informed that following K-wire removal, the residual holes could be subject to stress risers. (C) 2019 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 50 条
  • [1] Iatrogenic metacarpal fracture complication secondary to K-wire fixation
    Loh, Charles Yuen Yung
    Ng, Nigel Yong Boon
    Loh, Meiling
    Kandamany, Nanda
    Athanassopoulos, Thanassi
    INDIAN JOURNAL OF PLASTIC SURGERY, 2014, 47 (02) : 271 - 272
  • [2] An intraosseous epidermal cyst developing in a metacarpal bone after K-wire fixation: a case report
    Park, Il-Jung
    Kim, Hyoung-Min
    Lee, Jae-Young
    Park, Hyun-Woo
    Kang, Soo-Hwan
    SKELETAL RADIOLOGY, 2015, 44 (10) : 1523 - 1527
  • [3] An intraosseous epidermal cyst developing in a metacarpal bone after K-wire fixation: a case report
    Il-Jung Park
    Hyoung-Min Kim
    Jae-Young Lee
    Hyun-Woo Park
    Soo-Hwan Kang
    Skeletal Radiology, 2015, 44 : 1523 - 1527
  • [4] Intramedullary k-wire fixation of metacarpal fractures
    Kelsch, G
    Ulrich, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (08) : 523 - 526
  • [5] Intramedullary k-wire fixation of metacarpal fractures
    Georg Kelsch
    Christoph Ulrich
    Archives of Orthopaedic and Trauma Surgery, 2004, 124 : 523 - 526
  • [6] Fifth metacarpal neck fracture fixation: Locking plate versus K-wire?
    Facca, S.
    Ramdhian, R.
    Pelissier, A.
    Diaconu, M.
    Liverneaux, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) : 506 - 512
  • [7] Unusual migration of K-wire following fixation of clavicle fracture: a case report
    Bezer, Murat
    Aydin, Nuri
    Erol, Buelent
    Lacin, Yunc
    Guven, Osman
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2009, 15 (03): : 298 - 300
  • [8] Intraspinal K-wire migration after humeral fracture fixation
    Kedra, Mariusz
    Rybojad, Pawel
    Jendrej, Janusz
    Sawicki, Marek
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 1079 - 1079
  • [9] Multifragmentary proximal humerus fracture successfully treated with k-wire fixation: A case report
    Jayarajah, Umesh
    Amarasooriya, Melanie
    Sooriyarachchi, Rukshan
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 87
  • [10] Migration of K-wire after anterior dens screw fixation - Case report
    Ramsbacher, J
    Brock, M
    NEURO-ORTHOPEDICS, 2000, 28 (01): : 53 - 56