Measurement of the two-photon excitation cross-section of the 6p′[3/2]2 and 6p′[1/2]0 levels of Xe I at the wavelengths 224.3 and 222.6 nm

被引:10
|
作者
Drag, C. [1 ,2 ]
Marmuse, F. [1 ,2 ]
Blondel, C. [1 ,2 ]
机构
[1] Univ Paris Saclay, CNRS, Lab Phys Plasmas, Route Saclay, F-91128 Palaiseau, France
[2] Sorbonne Univ, Observ Paris, Inst Polytech Paris, Ecole Polytech, Route Saclay, F-91128 Palaiseau, France
来源
PLASMA SOURCES SCIENCE & TECHNOLOGY | 2021年 / 30卷 / 07期
关键词
TALIF; two-photon cross-section; xenon; two-photon absorption; cross-section ratios; LASER-INDUCED FLUORESCENCE; ATOMIC OXYGEN; ABSOLUTE CALIBRATION; DENSITY-MEASUREMENTS; TIME DEVELOPMENT; O-ATOMS; H-ATOM; ABSORPTION; SPECTROSCOPY; XENON;
D O I
10.1088/1361-6595/abfbeb
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The two-photon excitation cross-section is a key parameter for the two-photon absorption laser induced fluorescence (TALIF) method, which is commonly used to measure atomic densities in gaseous media, especially for plasma diagnostics. The method consists in recording the fluorescence signal that follows the resonant absorption of two photons of UV light. Calibration often relies on comparing the signal recorded in the studied sample with the fluorescence produced, at a similar wavelength, in a noble gas vapor, the density of which can be easily known. The ratio of the involved cross-sections however plays an essential role for the accuracy of such measurements. Yet the two-photon excitation cross-section of atomic xenon, which is often used as the reference for oxygen density measurements, was measured only once, at the wavelengths of interest. The aim of the present study has been to consolidate the experimental value of that key parameter. The cross-section is found equal to 1.36(-0.34)(+0.46) 1.88(-0.54)(+0.75)x10(-4)3m(4) p '[3/2](2) and 6p'[1/2](0) levels, respectively. For the 6p '[3/2](2) level this is more than twice smaller than previously admitted. Even though the necessarily large relative uncertainty of a non-linear cross-section attaches a relatively large uncertainty to this factor of one half, the result suggests that atomic densities already measured by Xe-calibrated TALIF may have to be revised to significantly lower values. The experiments performed also provide an opportunity to revisit the validity of the approximations used for quantitative TALIF measurements and the collisional broadening and pressure shift of the two-photon 6p'[1/2](0) line. A new formula has been used to describe the two-photon absorption of a Gaussian beam in a long gas cell, which makes the decrease of the beam intensity a simple analytic expression even in strong absorption regime, based on a polylogarithmic function of the absorption rate variable.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] ELECTRON-IMPACT EXCITATION OF RADIATIVE TRANSITIONS FROM 6P(2)(D-1(2) AND P-3(1)) LEVELS OF THALLIUM ION
    GOMONAI, AN
    IMRE, AI
    ZAPESOCHNY, AI
    KONTROS, EE
    ZAPESOCHNY, IP
    UKRAINSKII FIZICHESKII ZHURNAL, 1994, 39 (01): : 43 - 46
  • [32] REVISED 6P 2P1/2 LEVEL OF MO-XIV
    READER, J
    LUTHER, G
    ACQUISTA, N
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (02) : 204 - 204
  • [33] Magic wavelength for caesium transition line 6S1/2 - 6P 3/2
    School of Electronics Engineering and Computer Science, Peking University, Beijing 100871, China
    Chin. Phys. Lett., 2006, 7 (1687-1690):
  • [34] COLLISIONAL TRANSFER BETWEEN 6S'[1-2]0,1 AND 6P[1-2]1 XENON LEVELS
    SADEGHI, N
    SABBAGH, J
    PHYSICAL REVIEW A, 1977, 16 (06): : 2336 - 2345
  • [36] Collisional depolarization of Zeeman coherences in the 133Cs 6p 2P3/2 level:: Double-resonance two-photon polarization spectroscopy
    Bayram, SB
    Kin, S
    Welsh, MJ
    Hinkle, JD
    PHYSICAL REVIEW A, 2006, 73 (04)
  • [37] Multiphoton mass spectra of XeKr molecules in the range of excited Xe*6p[5/2]2, 3 atoms
    M. A. Khodorkovskiĭ
    A. A. Belyaeva
    L. P. Rakcheeva
    A. A. Pastor
    P. Yu. Serdobintsev
    N. A. Timofeev
    I. A. Shevkunov
    R. Hallin
    K. Siegbahn
    Optics and Spectroscopy, 2007, 102 : 834 - 841
  • [38] SCA1 MAPPING WITHIN 2 CM ON 6P
    PERSICHETTI, F
    JODICE, C
    MALASPINA, P
    NOVELLETTO, A
    SCHINAIA, G
    FRONTALI, M
    LULLI, P
    CAPPELLACCI, S
    GIUNTI, P
    TERRENATO, L
    CYTOGENETICS AND CELL GENETICS, 1991, 58 (3-4): : 1915 - 1916
  • [39] A STUDY OF THE ROLE PLAYED BY BUFFER GASES IN THE OPERATION OF A XE LASER DUE TO THE 5D[3/2]1(0)-6P[3/2]1 TRANSITION
    VERKHOGLYAD, AG
    KRIVOSHCHYOKOV, GV
    KURBATOV, PF
    KVANTOVAYA ELEKTRONIKA, 1981, 8 (06): : 1221 - 1228
  • [40] Measuring the Hyperfine Structure of the 6p, 7p, 4f and 5f Levels in 1 2 9 Xe and 1 3 1 Xe.
    Husson, X.
    Grandin, J.P.
    Kucal, H.
    Journal de physique Paris, 1979, 40 (06): : 551 - 555