A Monte Carlo simulation of out-of-field radiation from an 18-MV beam

被引:1
|
作者
Kry, S [1 ]
Titt, U [1 ]
Poenisch, F [1 ]
Followill, D [1 ]
Vassiliev, O [1 ]
Mohan, R [1 ]
Salehpour, M [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.1997408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Patients undergoing radiation therapy are exposed to out‐of‐field radiation in the form of scattered and leakage photons, and at photon energies greater than 10‐MV, neutrons. This secondary radiation may pose a health risk to the patient by inducing secondary cancers in long‐term survivors; it is also a great concern for pregnant patients. Although estimations and measurements of out‐of‐field doses are possible, they are typically crude or time consuming and measurements may be only applicable to the particular treatment examined. A more robust tool is needed that can calculate accurately, and with relative ease, out‐of‐field photon and neutron dose equivalents. Such a tool has been developed with Monte Carlo. Method and Materials: A Varian 2100 accelerator and treatment vault, operated at 18‐MV, have been simulated in detail with MCNPX (including head shielding and structure, gantry, and couch). The out‐of‐field photon dose and neutron fluence were simulated. Simulated photon doses were compared with those measured with TLD‐700 in an acrylic phantom. Simulated neutron fluences were compared with fast neutron fluences measured with moderated gold foils in the patient plane. Neutron fluence can be converted to dose equivalent via conversion factors provided by the ICRP Report 74. Results: From a 10cm × 10cm field, the simulated out‐of‐field photon doses were found to agree, on average, within 10% of measured data over the range of 5cm to 40cm from the edge of the treatment field. Simulated neutron fluences were found to agree within 22% of measured data. Conclusion: A Monte Carlo model has been developed that is capable of calculating both the photon and neutron dose equivalent out‐of‐field. This tool is a substantial improvement on conventional calculations of the out‐of‐field dose from radiation treatments. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1889 / 1889
页数:1
相关论文
共 50 条
  • [1] A Monte Carlo model for calculating out-of-field dose from a Varian 6 MV beam
    Kry, Stephen F.
    Titt, Uwe
    Ponisch, Falk
    Followill, David
    Vassiliev, Oleg N.
    White, R. Allen
    Mohan, Radhe
    Salehpour, Mohammad
    MEDICAL PHYSICS, 2006, 33 (11) : 4405 - 4413
  • [2] Out-of-field beam characteristics of a 6 MV photon beam: Results of a Monte Carlo study
    Atarod, M.
    Shokrani, P.
    Azarnoosh, A.
    APPLIED RADIATION AND ISOTOPES, 2013, 72 : 182 - 194
  • [3] A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam
    Mesbahi, Asghar
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 55 - 60
  • [4] Monte Carlo Simulation of the Neutron Radiation Field Around a Medical 18 MV Linac
    Horst, F.
    Czarnecki, D.
    Zink, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3464 - 3464
  • [5] A Monte Carlo study of the out-of-field dose from IMRT
    Kry, S.
    Salehpour, M.
    Titt, U.
    Stovall, M.
    White, R.
    Followill, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2406 - 2406
  • [6] Monte Carlo evaluation of out-of-field dose in 18 MV pelvic radiotherapy using a simplified female MIRD phantom
    Geraily, Ghazale
    Elmtalab, Soheil
    Mohammadi, Najmeh
    Alirezaei, Zahra
    Martinez-Ovalle, S. A.
    Jabbari, Iraj
    Vega-Carrillo, Hector Rene
    Karimi, Amir Hossein
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [7] Monte Carlo modelling of a 6 MV Elekta linear accelerator for in-field and out-of-field dosimetry
    Al-Saleh, Wafa M.
    Hugtenburg, Richard P.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 203
  • [8] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Asghar Mesbahi
    Farshad Seyed Nejad
    Radiation Medicine, 2008, 26 : 331 - 336
  • [9] Out-of-field radiation damage to the lung: Dosimetric analysis by Monte Carlo calculation
    Yeung, I.
    Darko, J.
    Osei, E.
    Van Dyk, J.
    Khan, M.
    Hill, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S5 - S6
  • [10] Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation
    Bednarz, Bryan
    Xu, X. George
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04): : N43 - N57