A Monte Carlo study of the out-of-field dose from IMRT

被引:0
|
作者
Kry, S. [1 ]
Salehpour, M. [1 ]
Titt, U. [1 ]
Stovall, M. [1 ]
White, R. [1 ]
Followill, D. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2760669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To calculate the out‐of‐field dose resulting from intensity‐modulated radiation therapy (IMRT) using Monte Carlo. Out‐of‐field radiation poses a health risk to the patient as it may induce late effects such as secondary malignancies. While this dose can be measured, measurements are time consuming and are specific to the irradiation conditions and patient examined. In contrast, Monte Carlo modeling can be flexible and applied to an arbitrary condition or patient, and may offer reasonable accuracy. Method and Materials: MCNPX was used to create a Monte Carlo model of a Varian 2100 accelerator and treatment vault. Step‐and‐shoot IMRT of the prostate was simulated at 6 MV and 18 MV. The simulated patient was an anthropomorphic phantom, the CT of which was converted to MCNPX format using Scan2MCNP. The dose from photons and the dose equivalent from neutrons were calculated at various organ locations throughout the phantom. These calculated doses were compared to measured doses that were previously published, based on the same anthropomorphic phantom and IMRT treatments. Results: The Monte Carlo model was able to accurately predict the out‐of‐field photon dose at both 6 MV and 18 MV. At 6 MV, the average absolute out‐of‐field photon dose was 14% different than measurement, while at 18 MV the average absolute out‐of‐field photon dose was 13% different than measurement. There have been a wide range of published neutron dose equivalents in phantom and our calculated neutron dose equivalents were consistent with these values. Conclusion: Using Monte Carlo it was possible to calculate the out‐of‐field dose equivalent resulting from complex therapies incident on a complex phantom. Such a Monte Carlo model would therefore be a useful tool for evaluating the out‐of‐field dose received by patients undergoing radiotherapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
下载
收藏
页码:2406 / 2406
页数:1
相关论文
共 50 条
  • [1] Validation of a Monte Carlo Framework for Out-of-Field Dose Calculations in Proton Therapy
    De Saint-Hubert, Marijke
    Verbeek, Nico
    Baeumer, Christian
    Esser, Johannes
    Wulff, Joerg
    Nabha, Racell
    Van Hoey, Olivier
    Dabin, Jeremie
    Stuckmann, Florian
    Vasi, Fabiano
    Radonic, Stephan
    Boissonnat, Guillaume
    Schneider, Uwe
    Rodriguez, Miguel
    Timmermann, Beate
    Thierry-Chef, Isabelle
    Brualla, Lorenzo
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [2] Analytic Technique to Calculate the Out-Of-Field Dose From IMRT Therapy
    Kry, S.
    Childress, N.
    Howell, R.
    Stovall, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] A Monte Carlo model for calculating out-of-field dose from a Varian 6 MV beam
    Kry, Stephen F.
    Titt, Uwe
    Ponisch, Falk
    Followill, David
    Vassiliev, Oleg N.
    White, R. Allen
    Mohan, Radhe
    Salehpour, Mohammad
    MEDICAL PHYSICS, 2006, 33 (11) : 4405 - 4413
  • [4] Characterization of Extrafocal Dose Influence on the Out-of-Field Dose Distribution by Monte Carlo Simulations and Dose Measurements
    Ghareeb, Firass
    Lencart, Joana
    Oliveira, Jorge
    Santos, Joao A. M.
    HEALTH PHYSICS, 2019, 117 (05): : 489 - 503
  • [5] A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy
    Kry, Stephen F.
    Titt, Uwe
    Followill, David
    Poenisch, Falk
    Vassiliev, Oleg N.
    White, R. Allen
    Stovall, Marilyn
    Salehpour, Mohammad
    MEDICAL PHYSICS, 2007, 34 (09) : 3489 - 3499
  • [6] Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter
    Almberg, S. S.
    Frengen, J.
    Lindmo, T.
    MEDICAL PHYSICS, 2012, 39 (08) : 5194 - 5203
  • [7] Automated Photon Monte Carlo Linear Accelerator Model for Calculating In-Field and Out-Of-Field Dose
    Randeniya, S.
    Mirkovic, D.
    Kry, S.
    Titt, U.
    Newhauser, W.
    Howell, R.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Calculation of out-of-field dose distribution in carbon-ion radiotherapy by Monte Carlo simulation
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Namba, Masao
    MEDICAL PHYSICS, 2012, 39 (08) : 5028 - 5039
  • [9] Investigation of the Attila Deterministic Solver as a Supplement to Monte Carlo for Calculating Out-Of-Field Radiotherapy Dose
    Mille, M.
    Lee, C.
    Failla, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3487 - 3487
  • [10] Study of out-of-field dose in photon radiotherapy: A commercial treatment planning system versus measurements and Monte Carlo simulations
    Sanchez-Nieto, B.
    Medina-Ascanio, K. N.
    Rodriguez-Mongua, J. L.
    Doerner, E.
    Espinoza, I
    MEDICAL PHYSICS, 2020, 47 (09) : 4616 - 4625