Fire-resistance of RHS stainless steel beams with three faces exposed to fire

被引:5
|
作者
Fan, Shenggang [1 ]
Du, Li [1 ]
Li, Shuai [1 ]
Zhang, Liyuan [2 ]
Shi, Ke [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Sipailou 2, Nanjing 210096, Jiangsu, Peoples R China
[2] Future Land Dev Holdings Ltd, Bldg 6,Lane 388,Zhongjiang Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Stainless steel beam; Section factor; Three faces exposed to fire; Fire resistance; Critical temperature; TEMPERATURE;
D O I
10.1016/j.jcsr.2018.04.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate fire-resistance behaviors of rectangular section stainless steel beams with three faces exposed to fire, fire resistance analysis models were established based on existing experiment data, and numerical simulation analysis was conducted. Comparison between the finite element calculation results and the experiment results verified the accuracy of the finite element models. On this basis, parametric analysis was carried out on the fire resistance behaviors of rectangular section stainless steel beams with three faces exposed to fire, with a focus on the influences of the section factor on the temperature distribution, mid-span vertical deformations and critical temperatures. Finally, the formula for the bearing capacity of the rectangular section stainless steel beams with three faces exposed to fire was fitted, providing important references for engineering designs of stainless steel structures in the future. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:284 / 295
页数:12
相关论文
共 50 条
  • [31] Finite element analysis of the fire-resistance capacity of steel frame girders
    School of Civil Engineering, Tianjin University, Tianjin 300072, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2006, 2 (181-187):
  • [32] FIRE-RESISTANCE STUDY OF RESTRAINED STEEL COLUMNS WITH INITIAL LATERAL DISPLACEMENT
    Zhang, Jin
    Xu, Yi-Xiang
    Yang, Xiao-Jing
    Zhang, Dong-Hao
    ADVANCED STEEL CONSTRUCTION, 2018, 14 (01): : 22 - 36
  • [33] Resistance of partially protected steel beams in fire
    Hautala, Janne
    Kangashaka, Iida
    Malaska, Mikko
    Pajunen, Sami
    ce/papers, 2021, 4 (2-4) : 1849 - 1855
  • [34] Analysis of the Fire-Resistance for Large-Space Steel Grid Structures
    Zhu Guopeng
    Li Yaozhuang
    Kuang Yuxing
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 735 - 739
  • [35] Fire resistance of stainless steel beams with rectangular hollow section: Numerical investigation and design
    Fan, Shenggang
    Chen, Guoqiang
    Xia, Xinfeng
    Ding, Zhixia
    Liu, Meijing
    FIRE SAFETY JOURNAL, 2016, 79 : 69 - 90
  • [36] Estimation of pine wood fire-resistance exposed to the heat emission using thermography
    Kasymov, D. P.
    Agafontsev, M. V.
    Perminov, V. V.
    Martynov, P. S.
    25TH INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2019, 11208
  • [38] Fire-resistance of six tree species to fire probed by chlorophyll fluorescence
    Deng, Chunnuan
    Pan, Xiangming
    Zhang, Hongyu
    Pan, Xiangliang
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2012, 10 (02): : 1329 - 1333
  • [39] Fire resistance of steel beams with integrated fire-resistant and decorative constructions
    Chu, Chengyi
    Ye, Xunan
    Fu, Bo
    Zhang, Lei
    Gao, Wang
    Fan, Dongdong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 223
  • [40] A numerical study on fire endurance of wood beams exposed to three-side fire
    Zhang, Jin
    Xu, Qing-feng
    Xu, Yi-xiang
    Wang, Bin
    Shang, Jing-xiang
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2012, 13 (07): : 491 - 505