The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis

被引:148
|
作者
Fluegge, Tabea [1 ,2 ]
van der Meer, Wicher Joerd [3 ,4 ]
Gonzalez, Beatriz Gimenez [2 ]
Vach, Kirstin [5 ]
Wismeijer, Daniel [2 ]
Wang, Ping [6 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg, Freiburg, Germany
[2] ACTA, Dept Oral Implantol, Amsterdam, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, Groningen, Netherlands
[4] WJ Kolff Inst Biomed Engn & Mat Sci, Groningen, Netherlands
[5] Univ Freiburg, Inst Med Biometry & Stat, Fac Med, Freiburg, Germany
[6] Temple Univ, Maurice H Kornberg Sch Dent, Philadelphia, PA 19122 USA
关键词
computer-aided design; digital implant impressions; implant impressions; intraoral scanning; 3-DIMENSIONAL ACCURACY; DIMENSIONAL ACCURACY; EDENTULOUS PATIENTS; MULTIPLE IMPLANTS; VULTIPLE IMPLANTS; ANGULATION; CASTS; FIT; TECHNOLOGY; PRECISION;
D O I
10.1111/clr.13273
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This systematic review and meta-analysis were conducted to assess and compare the accuracy of conventional and digital implant impressions. The review was registered on the PROSPERO register (registration number: CRD42016050730). Material and Methods: A systematic literature search was conducted adhering to PRISMA guidelines to identify studies on implant impressions published between 2012 and 2017. Experimental and clinical studies at all levels of evidence published in peer-reviewed journals were included, excluding expert opinions. Data extraction was performed along defined parameters for studied specimens, digital and conventional impression specifications and outcome assessment. Results: Seventy-nine studies were included for the systematic review, thereof 77 experimental studies, one RCT and one retrospective study. The study setting was in vitro for most of the included studies (75 studies) and in vivo for four studies. Accuracy of conventional impressions was examined in 59 studies, whereas digital impressions were examined in 11 studies. Nine studies compared the accuracy of conventional and digital implant impressions. Reported measurements for the accuracy include the following: (a) linear and angular deviations between reference models and test models fabricated with each impression technique; (b) three-dimensional deviations between impression posts and scan bodies respectively; and (c) fit of implant-supported frameworks, assessed by measuring marginal discrepancy along implant abutments.) Meta-analysis was performed of 62 studies. The results of conventional and digital implant impressions exhibited high values for heterogeneity. Conclusions: The available data for accuracy of digital and conventional implant impressions have a low evidence level and do not include sufficient data on in vivo application to derive clinical recommendations.
引用
收藏
页码:374 / 392
页数:19
相关论文
共 50 条
  • [21] Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses
    Ma, Yun
    Guo, Yong-qing
    Jiang, Lei
    Yu, Hao
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 633 - 640
  • [22] The accuracy of conventional versus digital (intraoral scanner or photogrammetry) impression techniques in full-arch implant-supported prostheses: a systematic review
    Joensahakij, Nitchakul
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    EVIDENCE-BASED DENTISTRY, 2024, 25 (04) : 216 - 217
  • [23] The Use of Zirconia for Implant-Supported Fixed Complete Dental Prostheses: A Narrative Review
    Cinquini, Chiara
    Alfonsi, Fortunato
    Marchio, Vincenzo
    Gallo, Francesco
    Zingari, Francesco
    Bolzoni, Alessandro Remigio
    Romeggio, Stefano
    Barone, Antonio
    DENTISTRY JOURNAL, 2023, 11 (06)
  • [24] RESEARCH AND EDUCATION Maintenance protocols for implant-supported dental prostheses: A scoping review
    Soares, Pablo Machado
    Silveira, Gabriela do Amaral
    Goncalves, Luciano de Souza
    Bacchi, Atais
    Pereira, Gabriel Kalil Rocha
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 59 - 71
  • [25] An Overview of Systematic Reviews and Meta-analyses Evaluating Different Impression Techniques for Implant-Supported Prostheses in Partially and Completely Edentulous Arches
    Gaikwad, Amit M.
    Joshi, Amruta A.
    De Oliveira-Neto, Olavo B.
    Padhye, Ashvini M.
    Nadgere, Jyoti B.
    Ram, Sabita M.
    Yadav, Seema R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1119 - 1137
  • [26] Full-arch implant-supported monolithic zirconia fixed dental prostheses: An updated systematic review
    AlTarawneh, Sandra
    Thalji, Ghadeer
    Cooper, Lyndon
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (01) : 13 - 22
  • [27] Impact of immediately loaded implant-supported maxillary full-arch dental prostheses: a systematic review
    Abdunabi, Ahlam
    Morris, Martin
    Nader, SamerAbi
    de Souza, Raphael F.
    JOURNAL OF APPLIED ORAL SCIENCE, 2019, 27
  • [28] Screwmentable implant-supported prostheses: A systematic review
    Sara, Katia
    Vasileiadi, Georgia
    Louvrou, Marilena Kalliopi
    Moldovani, Eirini
    Koidis, Petros
    Kokoti, Maria
    Bakopoulou, Athina
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (01): : 35 - 47
  • [29] Clinical Outcomes of Metal-Ceramic vs Metal-Acrylic Resin Implant-Supported Fixed Complete Dental Prostheses: A Systematic Review and Meta-analysis
    Estrin, Nathan
    Nam, Kyung
    Romanos, Georgios E.
    Saragossi, Jamie
    Iacono, Vincent J.
    Bassir, Seyed Hossein
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (03) : 354 - +
  • [30] Open Proximal Contact with Implant-Supported Fixed Prostheses Compared with Tooth-Supported Fixed Prostheses: A Systematic Review and Meta-analysis
    Oh, Won-Suk
    Oh, Joon
    Valcanaia, Andre Joao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (06) : E99 - E108