Characterization of the low-frequency noise in high-temperature radio frequency superconducting quantum interference devices cooled in static magnetic fields

被引:1
|
作者
Borgmann, J [1 ]
David, P
Otto, R
Schubert, J
Braginski, AI
机构
[1] Univ Bonn, Inst Strahlen & Kernphys, D-53117 Bonn, Germany
[2] Forschungszentrum Julich, Inst Schicht & Ionentech, D-52425 Julich, Germany
关键词
D O I
10.1063/1.123442
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7-x washer rf SQUIDs was measured in static magnetic fields up to 55 mu T. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs S-Phi(1/2) at 1 Hz was between 70 and 350 mu Phi(0)/root Hz, and in terms of magnetic field noise S-B(1/ 2) between 120 and 1100 fT/root Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields. (C) 1999 American Institute of Physics. [S0003-6951(99)01306-6].
引用
收藏
页码:1021 / 1023
页数:3
相关论文
共 50 条
  • [31] Towards noise engineering: Recent insights in low-frequency excess flux noise of superconducting quantum devices
    Kempf, Sebastian
    Ferring, Anna
    Enss, Christian
    APPLIED PHYSICS LETTERS, 2016, 109 (16)
  • [32] Numerical modeling of superconducting coplanar resonators for radio frequency superconducting quantum interference devices
    Yi, HR
    Zhang, Y
    Braginski, AI
    APPLIED PHYSICS LETTERS, 1998, 73 (16) : 2357 - 2359
  • [33] A radio-frequency high-temperature superconducting magnetometer
    Ignatjev, VK
    Yakimets, AL
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (01) : 122 - 126
  • [34] A Radio-Frequency High-Temperature Superconducting Magnetometer
    V. K. Ignatjev
    A. L. Yakimets
    Instruments and Experimental Techniques, 2002, 45 : 122 - 126
  • [35] Characterization and Modelling of Low-Frequency Noise in PCM devices
    Fantini, P.
    Beneventi, G. Betti
    Calderoni, A.
    Larcher, L.
    Pavan, P.
    Pellizzer, F.
    IEEE INTERNATIONAL ELECTRON DEVICES MEETING 2008, TECHNICAL DIGEST, 2008, : 219 - +
  • [36] High-temperature superconducting quantum interference device with cooled LC resonant circuit for measuring alternating magnetic fields with improved signal-to-noise ratio
    Qiu, Longqing
    Zhang, Yi
    Krause, Hans-Joachim
    Braginski, Alex I.
    Usoskin, Alexander
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (05):
  • [37] RESPONSE OF RADIO-FREQUENCY SUPERCONDUCTING QUANTUM INTERFERENCE DEVICES TO ELECTROMAGNETIC-INTERFERENCE
    MUCK, M
    DECHERT, J
    GAIL, J
    KREUTZBRUCK, M
    SCHONE, S
    WEIDL, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (09): : 4690 - 4693
  • [38] Low-frequency noise reduction in YBa2Cu3O7-δ superconducting quantum interference devices by antidots
    Selders, P
    Wördenweber, R
    APPLIED PHYSICS LETTERS, 2000, 76 (22) : 3277 - 3279
  • [39] High-temperature superconducting high-frequency SQUID devices
    Firsov, N.I.
    Shadrin, V.S.
    Ryabov, E.V.
    Khabarov, S.P.
    Golovnev, A.G.
    Pribory i Sistemy Upravleniya, 1993, (05):
  • [40] Inductance of Low-Frequency Small-Scale High-Temperature Superconducting Coils
    Chen, Siwei
    Gu, Chen
    Li, Yi
    Lai, Lingfeng
    Qu, Timing
    Hu, Nannan
    Song, Meng
    Zou, Shengnan
    Yue, Yubin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)