In vivo diode dosimetry for routine quality assurance in IMRT

被引:49
|
作者
Higgins, PD [1 ]
Alaei, P [1 ]
Gerbi, BJ [1 ]
Dusenbery, KE [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Therapeut Radiol Radiat Oncol, Minneapolis, MN 55455 USA
关键词
IMRT QA; diode dosimetry; in vivo dosimetry;
D O I
10.1118/1.1626989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the complexity of IMRT dosimetry, dose delivery evaluation is generally done using a treatment plan in which the optimized fluence distribution has been transferred to a test phantom for accessibility and simplicity of measurement. The actual patient doses may be reconstructed in vivo through the use of electronic portal imaging devices or films, but the assessment of absolute dose from these measurements is time-consuming and complicated. In our clinic we have instituted the use of routine diode dosimetry for IMRT patients following the same procedure used for standard radiation therapy patients in which each new treatment field is checked at the start of treatment. For standard cases the dose at d(max) is calculated as part of the monitor unit calculation. For the IMRT cases, the dose contribution to the d(max) depth for each field is taken from the treatment plan. We found that about 90% of the diode measurements agreed to within +/- 10% of the planned doses (45/51 fields) and 63% (32/51 fields) achieved +/-5% agreement. By using this direct in vivo method to verify the clinical doses delivered, we have been able to make a uniform startup procedure for all patients while simplifying our IMRT QA process. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:3118 / 3123
页数:6
相关论文
共 50 条
  • [1] In vivo diode dosimetry for routine quality assurance in IMRT
    Higgins, P
    Alaei, P
    Gerbi, B
    Dusenbery, K
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1500 - 1501
  • [2] Diode dosimetry for the routine quality assurance in IMRT
    Xu, Z.
    Yang, G.
    Li, W.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2437 - 2437
  • [3] The use of diode in in-vivo dosimetry quality assurance in IMRT
    Kim, H
    Wang, Z
    Lalonde, R
    Sontag, M
    Chen, H
    Li, F
    Smith, R
    Huq, M
    Heron, D
    Yue, N
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1988 - 1989
  • [4] Comment on "In vivo diode dosimetry for routine quality assurance in IMRT" -: [Med. Phys. 30, 3118-3123 (2003)]
    Jornet, N
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1642 - 1643
  • [5] In vivo semiconductor dosimetry as part of routine quality assurance
    Millwater, CJ
    Macleod, AS
    Thwaites, DI
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846): : 661 - 668
  • [6] An intercomparison between film dosimetry and diode matrix for IMRT quality assurance
    Buonamici, F. Banci
    Compagnucci, A.
    Marrazzo, L.
    Russo, S.
    Bucciolini, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1372 - 1379
  • [7] Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance
    AL-Shareef, Jamal M.
    Attalla, Ehab M.
    El-Gebaly, Reem H.
    Deiab, Nashaat A.
    Abdelmajeed, M.
    Fathy, Mohamed M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 187
  • [8] Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance
    AL-Shareef, Jamal M.
    Attalla, Ehab M.
    El-Gebaly, Reem H.
    Deiab, Nashaat A.
    Abdelmajeed, M.
    Fathy, Mohamed M.
    [J]. Radiation Physics and Chemistry, 2021, 187
  • [9] In-vivo diode Dosimetry for IMRT fields
    Circiumaru, O.
    Zhu, T.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2111 - 2111
  • [10] Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer
    Wertz, Hansjoerg
    Boda-Heggemann, Judit
    Walter, Cornelia
    Dobler, Barbara
    Mai, Sabine
    Wenz, Frederik
    Lohr, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (01): : 288 - 295