A current sensor for insulator corona discharge measurement

被引:0
|
作者
Huang, XQ [1 ]
Song, W [1 ]
Chen, Y [1 ]
Yuan, YC [1 ]
ChengRong, L [1 ]
机构
[1] Henan Elect Power Res Inst, Zhengzhou 450004, Peoples R China
来源
1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS | 1998年
关键词
D O I
10.1109/ISEIM.1998.741868
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results from reference [1] indicated that it could be a way to detect faulty insulators by measuring corona pulse current from the insulator string. This paper presents a pulse current sensor, with high sensitivity (mu A) and wide frequency band (7kHz-25MHz), developed for detecting pulse currents form insulator corona discharges on line. Through spectrum analysis of corona pulse currents produced by 110kV-suspension insulator string, we found that the frequency band and 3-dB cutoff frequency of the corona pulse currents are respectively 17MHz and 2. 5MHz. Based on the spectrum analysis, we developed a special designed Rogowski coil to detect corona currents on transmission line, which has a core made of super microcrystal material. We tested the core material and found that it is of high Ct value (magnetic permeability, >10000) and wide frequency characteristics (2kHz-25MHz). In order to make the best design, the influence of coil turns and integrating resistance on the frequency band and sensitivity of the sensor was investigated, it was found from the test that the sensitivity of the sensor changes with integrating resistance. The larger the integrating resistance is, the higher the sensitivity of the sensor is, and the narrower the Frequency band of the sensor will be. The central frequency of the band changes with coil turns. The more the coil turns are, the lower the central frequency will be, the lower the sensitivity of the sensor will be. Considering the sensitivity and on-site interference, the integrating resistance and coil turns are chosen as 100 Ohm and 25MHz. The designed sensor was used to measure the corona pulse current produced by an insulator string by coupling from a ground wire of a tower in our laboratory. It is shown from the on-site that the sensor is very suitable to detecting corona pulse currents from insulator string in service.
引用
收藏
页码:799 / 802
页数:4
相关论文
共 50 条
  • [21] Modeling and measurement of microfabricated corona discharge structures
    Ongkodjojo, Andojo
    Li, Dachao
    Roberts, Robert C.
    Liu, Qingquan
    Tien, Norman C.
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 932 - 937
  • [22] Influence of the corona discharge on DC current.
    Tsoniff, B.
    Burger, A. A.
    2012 IEEE POWER ENGINEERING SOCIETY CONFERENCE AND EXPOSITION IN AFRICA (POWERAFRICA), 2012,
  • [23] Measurement of hydroxyl radicals in pulsed corona discharge
    Ono, R
    Oda, T
    JOURNAL OF ELECTROSTATICS, 2002, 55 (3-4) : 333 - 342
  • [24] Experimental analysis of direct current corona discharge
    Iagar, A.
    Dinis, C. M.
    Popa, G. N.
    INTERNATIONAL CONFERENCE ON APPLIED SCIENCES (ICAS2016), 2017, 163
  • [25] ELECTRIC WIND IN A CORONA DISCHARGE - THEORY AND MEASUREMENT
    HILPERT, J
    KERN, J
    ARCHIV FUR ELEKTROTECHNIK, 1974, 56 (01): : 50 - 54
  • [26] DISCHARGE CURRENT FROM CORONA CHARGED POLYETHYLENE
    SAWA, G
    LEE, DC
    IEDA, M
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (05) : 643 - 649
  • [27] FUNDAMENTAL LIMITATIONS IN THE MEASUREMENT OF CORONA AND PARTIAL DISCHARGE
    BOGGS, SA
    STONE, GC
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (02): : 143 - 150
  • [28] Study on influencing factors of ion current density measurement in corona discharge of HVDC transmission lines
    Liu, Shiqiang
    Li, Shouzheng
    Jiang, Yuze
    Jiang, Nan
    Li, Jie
    Wu, Yan
    PLASMA SCIENCE & TECHNOLOGY, 2020, 22 (04)
  • [29] Study on influencing factors of ion current density measurement in corona discharge of HVDC transmission lines
    刘士强
    李守正
    姜雨泽
    姜楠
    李杰
    吴彦
    Plasma Science and Technology, 2020, 22 (04) : 3 - 9
  • [30] Study on influencing factors of ion current density measurement in corona discharge of HVDC transmission lines
    刘士强
    李守正
    姜雨泽
    姜楠
    李杰
    吴彦
    Plasma Science and Technology, 2020, (04) : 3 - 9