Comparison of sensitivities of macro EMG and concentric needle EMG in L4 radiculopathy

被引:3
|
作者
Ulas, UH [1 ]
Cengiz, B [1 ]
Alanoglu, E [1 ]
Ozdag, MF [1 ]
Odabasi, Z [1 ]
Vural, O [1 ]
机构
[1] Gulhane Med Sch, Dept Neurol, TR-06018 Ankara, Turkey
关键词
macro EMG; concentric needle EMG; quantitative MUP analysis; radiculopathy; diagnostic yield;
D O I
10.1007/s10072-003-0150-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this study was to compare the sensitivities of macro EMG (mEMG) and concentric needle EMG (cnEMG) in showing abnormality in L4 radiculopathy. We evaluated 23 patients with clinically and radiologically proven L4 root lesions. Among these patients, 21 (92%) had cnEMG abnormalities. Out of 21 patients with cnEMG abnormality, 3 (14%) had fibrillations and positive sharp waves, 8 (38%) had interference pattern abnormality and all of them had motor unit potential (MUP) abnormality on quantitative MUP analysis. Seventeen patients (74%) had mEMG abnormality. Diagnostic yield of cnEMG is higher than mEMG in L4 radiculopathy. mEMG may not contribute much to the diagnosis of lumbar radiculopathy.
引用
收藏
页码:258 / 260
页数:3
相关论文
共 50 条
  • [21] THE SPECTRUM OF CONCENTRIC MACRO EMG CORRELATIONS .1. NORMAL SUBJECTS
    BAUERMEISTER, W
    JABRE, JF
    MUSCLE & NERVE, 1992, 15 (10) : 1081 - 1084
  • [22] CONCENTRIC MACRO-EMG ROLE IN ELECTRODIAGNOSTIC EVALUATIONOF INFLAMATORY MYOPATHY
    Hussein, AyatAllah
    Afifi, Lamiaa
    Ahmad, Sandra
    Zamarany, Eman
    Ateya, Eman
    MUSCLE & NERVE, 2022, 66 : S58 - S58
  • [23] SIMULATION OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    SANDERS, DB
    STALBERG, EV
    MUSCLE & NERVE, 1984, 7 (07) : 562 - 562
  • [24] SIMULATION OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    SANDERS, DB
    STALBERG, EV
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 60 (05): : P103 - P103
  • [25] DECOMPOSITION OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    SANDERS, DB
    MUSCLE & NERVE, 1989, 12 (09) : 752 - 753
  • [26] SIMULATION OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    SANDERS, DB
    STALBERG, EV
    ANDREASSEN, S
    MUSCLE & NERVE, 1988, 11 (02) : 151 - 159
  • [27] RECORDING CHARACTERISTICS OF DISPOSABLE VERSUS REUSABLE CONCENTRIC EMG NEEDLE ELECTRODES
    TEDMAN, BM
    NANDEDKAR, SD
    SANDERS, DB
    MUSCLE & NERVE, 1989, 12 (09) : 753 - 753
  • [28] MACRO-EMG, SINGLE FIBER EMG AND CONVENTIONAL NEEDLE EMG IN ESTIMATING FUNCTIONAL-STATE OF MOTOR UNITS IN PATIENTS WITH NEUROGENIC DISORDERS
    KASATKINA, L
    GECHT, B
    MUSCLE & NERVE, 1990, 13 (10) : 982 - 982
  • [29] Single-fiber EMG with a concentric needle electrode: Validation in myasthenia gravis
    Sarrigiannis, PG
    Kennett, RP
    Read, S
    Farrugia, ME
    MUSCLE & NERVE, 2006, 33 (01) : 61 - 65
  • [30] THE TIME COURSE OF CREATINE-KINASE ELEVATION FOLLOWING CONCENTRIC NEEDLE EMG
    LEVIN, R
    PASCUZZI, RM
    BRUNS, DE
    BOYD, JC
    TOLY, TM
    PHILLIPS, LH
    MUSCLE & NERVE, 1987, 10 (03) : 242 - 245