A rapid detection method using flow cytometry to monitor the risk of Legionella in bath water

被引:8
|
作者
Taguri, Toshitsugu [1 ]
Oda, Yasunori [2 ]
Sugiyama, Kanji [3 ]
Nishikawa, Toru [1 ]
Endo, Takuro [4 ]
Izumiyama, Shinji [5 ]
Yamazaki, Masayuki [6 ]
Kura, Fumiaki [4 ]
机构
[1] Nagasaki Prefectural Inst Environm Res & Publ Hlt, Nagasaki 8560026, Japan
[2] Sysmex Corp, Sci Instrumentat Business Div, Nishi Ku, Kobe, Hyogo 6512271, Japan
[3] Shizuoka Inst Environm & Hyg, Dept Microbiol, Aoi Ku, Shizuoka 4208637, Japan
[4] Natl Inst Infect Dis, Dept Bacteriol 1, Shinjuku Ku, Tokyo 1628640, Japan
[5] Natl Inst Infect Dis, Dept Parasitol, Shinjuku Ku, Tokyo 1628640, Japan
[6] Nissan Chem Ind, Dept Environm Chem, Chiyoda Ku, Tokyo 1010054, Japan
基金
日本科学技术振兴机构;
关键词
Chlorination; Hot tub; Legionella control; Rapid detection method; LEGIONNAIRES-DISEASE; FRESH-WATER; CHLORINATION; PNEUMOPHILA; BACTERIA; ENUMERATION;
D O I
10.1016/j.mimet.2011.03.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0 x 10(3) (3.48 log) counts mL(-1). We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with >= 3.48 or <3.48 log total bacterial counts mL(-1) were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at bathing acilities, especially those where the effectiveness of chlorine is reduced by the presence of Fe2+, Mn2+, NH4+, skin debris, and/or biofilms in the water. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [21] Detection of Legionella pneumophila on clinical samples and susceptibility assessment by flow cytometry
    Faria-Ramos, I.
    Costa-de-Oliveira, S.
    Barbosa, J.
    Cardoso, A.
    Santos-Antunes, J.
    Rodrigues, A. G.
    Pina-Vaz, C.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (12) : 3351 - 3357
  • [22] A simple and rapid method for the detection of poly(ADP-ribose) by flow cytometry
    Ogata, S
    Okumura, K
    Taguchi, H
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2000, 64 (03) : 510 - 515
  • [23] A rapid method for infectivity titration of Andes hantavirus using flow cytometry
    Barriga, Gonzalo P.
    Martinez-Valdebenito, Constanza
    Galeno, Hector
    Ferres, Marcela
    Lozach, Pierre-Yves
    Tischler, Nicole D.
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 291 - 294
  • [24] A new method for the detection of Pneumocystis jirovecii using flow cytometry
    J. Barbosa
    C. Bragada
    S. Costa-de-Oliveira
    E. Ricardo
    A. G. Rodrigues
    C. Pina-Vaz
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 1147 - 1152
  • [25] A new method for the detection of Pneumocystis jirovecii using flow cytometry
    Barbosa, J.
    Bragada, C.
    Costa-de-Oliveira, S.
    Ricardo, E.
    Rodrigues, A. G.
    Pina-Vaz, C.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (09) : 1147 - 1152
  • [26] A novel and rapid Legionella detection system for water analysis
    Giglio, Steven
    Monis, Paul T.
    Saint, Christopher P.
    LEGIONELLA: STATE OF THE ART 30 YEARS AFTER ITS RECOGNITION, 2006, : 453 - +
  • [27] Rapid Detection of Flavobacterium psychrophilum Using Fluorescent Magnetic Beads and Flow Cytometry
    Hibi, Kyoko
    Yoshiura, Yasutoshi
    Ushio, Hideki
    Ren, Huifeng
    Endo, Hideaki
    SENSORS AND MATERIALS, 2012, 24 (06) : 311 - 322
  • [28] Rapid quantification method for Legionella pneumophila in surface water
    Wunderlich, Anika
    Torggler, Carmen
    Elsaesser, Dennis
    Lueck, Christian
    Niessner, Reinhard
    Seidel, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (09) : 2203 - 2213
  • [29] Rapid quantification method for Legionella pneumophila in surface water
    Anika Wunderlich
    Carmen Torggler
    Dennis Elsässer
    Christian Lück
    Reinhard Niessner
    Michael Seidel
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2203 - 2213
  • [30] Legionella in drinking water: the detection method matters
    Zacharias, Nicole
    Wasser, Felix
    Freier, Lia
    Spies, Kirsten
    Koch, Christoph
    Pleischl, Stefan
    Mutters, Nico T.
    Kistemann, Thomas
    JOURNAL OF WATER AND HEALTH, 2023, 21 (07) : 884 - 894