Thermal performance of a pump-driven loop heat pipe as an air-to-air energy recovery device

被引:27
|
作者
Zhou, Feng [1 ]
Duan, Wei [1 ]
Ma, Guoyuan [1 ]
机构
[1] Beijing Univ Technol, Coll Environm & Energy Engn, Beijing 100124, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Pump; Loop heat pipe; Energy recovery; Refrigerant; Mass flow rate; COOLING LOOP; DATA CENTERS; SYSTEM; EXCHANGERS;
D O I
10.1016/j.enbuild.2017.06.057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A pump-driven loop heat pipe (PLHP) was proposed for energy recovery from exhaust air to reduce fresh air handling energy consumption of air conditioning systems. The influences of working fluid, mass flow rate, heat exchanging area and facing air velocity on heat transfer capacity, temperature effectiveness and coefficient of performance (COP) were studied experimentally under different working conditions. The optimum working fluid and value were obtained, respectively. Results indicate that the heat transfer capacity and COP increase with the temperature difference between indoor and outdoor air while the temperature effectiveness decreases. The general performance for R32 as working fluid was better than R22 and R152a. For summer condition, the heat transfer capacity was 4.09 kW and the COP was 9.26 when the mass flow rate was 250 kg h(-1), the heat exchanging area was 58.0 m(2) and the facing air velocity was 1.8 ms(-1). For winter condition, the heat transfer capacity was 6.63 kW and the COP was 14.20 while the mass flow rate was 300 kg h(-1), the heat exchanging area was 58.0 m(2) and the facing air velocity was 1.8 m s(-1). The tested device could meet the energy recovery need with remarkable energy savings. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 216
页数:11
相关论文
共 50 条
  • [21] Heat recovery in an air-conditioning system with air-to-air heat exchanger
    Papakostas, K.T.
    Kiosis, G.C.
    International Journal of Sustainable Energy, 2015, 34 : 221 - 231
  • [22] Impact of Heat Pump-Driven Liquid Desiccant Dehumidification on the Energy Performance of an Evaporative Cooling-Assisted Air Conditioning System
    Shin, Jang-Hoon
    Park, Joon-Young
    Jo, Min-Suk
    Jeong, Jae-Weon
    ENERGIES, 2018, 11 (02)
  • [23] Applicability of air-to-air heat recovery ventilators in China
    Zhong Ke
    Kang Yanming
    APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 830 - 840
  • [24] Performance analysis of a rooftop, air-to-air heat pump working with CO2
    Calabrese, Nicolandrea
    Mastrullo, Rita
    Mauro, Alfonso William
    Rovella, Paola
    Tammaro, Marcello
    APPLIED THERMAL ENGINEERING, 2015, 75 : 1046 - 1054
  • [25] Performance analysis of a new kind of heat pump-driven outdoor air processor using solid desiccant
    Tu, Rang
    Liu, Xiao-Hua
    Jiang, Yi
    RENEWABLE ENERGY, 2013, 57 : 101 - 110
  • [26] Improvement of Thermal Performance using Spineloxides/Water Nanofluids in the Heat Recovery Unit with Air-to-Air Thermosiphone Mechanism
    İpek Aytaç
    Adnan Sözen
    Kerim Martin
    Çağdaş Filiz
    Hafiz Muhammad Ali
    International Journal of Thermophysics, 2020, 41
  • [27] Improvement of Thermal Performance using Spineloxides/Water Nanofluids in the Heat Recovery Unit with Air-to-Air Thermosiphone Mechanism
    Aytac, Ipek
    Sozen, Adnan
    Martin, Kerim
    Filiz, Cagdas
    Ali, Hafiz Muhammad
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2020, 41 (11)
  • [28] AIR-TO-AIR HEAT-EXCHANGER PERFORMANCE
    DROST, MK
    ENERGY AND BUILDINGS, 1993, 19 (03) : 215 - 220
  • [29] Performance evaluation of a heat pump-driven liquid desiccant dehumidification system integrated with fresh air supply
    Li, Wenzhang
    Yin, Yonggao
    Wang, Yikai
    ENERGY AND BUILDINGS, 2022, 275
  • [30] Development and analysis of a pump-driven loop heat pipe unit for cooling a small data center
    Zhou, Feng
    Wei, Chuancheng
    Ma, Guoyuan
    APPLIED THERMAL ENGINEERING, 2017, 124 : 1169 - 1175