Seismic performance and fragility analysis of underground subway station with rubber bearings

被引:10
|
作者
Liu, Di [1 ]
Xu, Chengshun [1 ]
Du, Xiuli [1 ]
El Naggar, Hesham M. [2 ]
Jiang, Jiawei [3 ]
机构
[1] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing, Peoples R China
[2] Western Univ, Dept Civil & Environm Engn, London, ON, Canada
[3] Nanjing Tech Univ, Inst Geotech Engn, Nanjing, Peoples R China
关键词
Seismic performance; Seismic fragility; Incremental dynamic analysis; Rubber bearings; MOUNTAIN TUNNELS; DYNAMIC-RESPONSE; SQUARE TUNNELS; DAMAGE; DESIGN; MECHANISMS;
D O I
10.1016/j.soildyn.2022.107511
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this paper, a comparative study of the seismic response and fragility of a station structure before and after being retrofitted with an LNB installed on the top of its columns is conducted to evaluate the effectiveness of retrofitting measures in reducing risk probability employing, for the first time, a probabilistic approach. The Daikai subway station was adopted as a case study, and two-dimensional finite element models of soil-structure system with and without LNB were established. Incremental dynamic analyses (IDA) of original and retrofitted structures were conducted to evaluate their seismic responses under different ground motion intensities and considering the uncertainty of ground motion. Further, the IDA curve cluster and quantile lines of station structure and rubber bearing were constructed. Finally, the seismic fragility curves of structure and LNB were established for the risk assessment under different performance levels based on the structural performance index. The results demonstrated that the horizontal deformation, shear force and bending moment of the central column fitted with rubber bearings are greatly reduced compared with the actual Daikai station structure, which is more pronounced for lower ground motion intensity. In addition, the failure probability of the retrofitted structure corresponding to different damage levels is much lower than that of the original structure under the same ground motion intensity. Meanwhile, the probability of moderate to severe damage for the underground station structure is greatly reduced after retrofitting with the rubber bearings. The overall seismic performance of the structure is significantly improved and post-earthquake repair-demand is greatly decreased.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Seismic response and damage of underground subway station in a slightly sloping liquefiable site
    Chen, Su
    Wang, Xu
    Zhuang, Haiyang
    Xu, Changjie
    Zhao, Kai
    BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (11) : 5963 - 5985
  • [32] Influence of ground structure on the seismic response of underground subway station in soft site
    Long, Hui
    Chen, Guoxing
    Zhuang, Haiyang
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 2769 - 2775
  • [33] 2-D SEISMIC FRAGILITY ANALYSIS AND STRUCTURAL TYPE EFFECT OF A MULTI-SPAN SUBWAY STATION
    Yu, Hai-Tao
    Chen, Zhi-Yi
    Yuan, Yong
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1917 - 1922
  • [34] Seismic Analysis of Separated Platform Subway Station Structure
    Zhou, Yao
    Wang, Zhiwei
    Wang, Yuanfeng
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4138 - +
  • [35] Seismic performance of a rectangular subway station with earth retaining system
    Ma Chao
    Lu Dechun
    Du Xiuli
    Qi Chengzhi
    Earthquake Engineering and Engineering Vibration, 2022, 21 (01) : 221 - 236
  • [36] Seismic performance of subway station based on failure model control
    Lu D.-C.
    Li Q.
    Du X.-L.
    Wu C.-Y.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2019, 41 (08): : 1400 - 1407
  • [37] Seismic performance of a rectangular subway station with earth retaining system
    Ma Chao
    Lu Dechun
    Du Xiuli
    Qi Chengzhi
    Earthquake Engineering and Engineering Vibration, 2022, 21 : 221 - 236
  • [38] Seismic performance of a rectangular subway station with earth retaining system
    Ma Chao
    Lu Dechun
    Du Xiuli
    Qi Chengzhi
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2022, 21 (01) : 221 - 236
  • [39] Seismic performance and failure mechanism of a subway station based on nonlinear finite element analysis
    Li, Wenting
    Chen, Qingjun
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (02) : 765 - 776
  • [40] Seismic performance and failure mechanism of a subway station based on nonlinear finite element analysis
    Wenting Li
    Qingjun Chen
    KSCE Journal of Civil Engineering, 2018, 22 : 765 - 776