Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope

被引:16
|
作者
Michimura, Yuta [1 ]
Shimoda, Tomofumi [1 ]
Miyamoto, Takahiro [2 ]
Shoda, Ayaka [3 ]
Okutomi, Koki [3 ,4 ]
Fujii, Yoshinori [3 ]
Tanaka, Hiroki [2 ]
Barton, Mark A. [3 ]
Takahashi, Ryutaro [3 ]
Aso, Yoichi [3 ,4 ]
Akutsu, Tomotada [3 ]
Ando, Masaki [1 ,3 ,5 ]
Enomoto, Yutaro [1 ]
Flaminio, Raffaele [3 ]
Hayama, Kazuhiro [6 ]
Hirose, Eiichi [2 ,6 ]
Inoue, Yuki [7 ,8 ]
Kajita, Takaaki [2 ]
Kamiizumi, Masahiro [6 ]
Kawamura, Seiji [6 ]
Kokeyama, Keiko [6 ]
Komori, Kentaro [1 ]
Kumar, Rahul [8 ]
Miyakawa, Osamu [6 ]
Nagano, Koji [2 ]
Nakano, Masayuki [2 ]
Ohishi, Naoko [3 ]
Ooi, Ching Pin [1 ]
Pena Arellano, Fabian Erasmo [3 ]
Saito, Yoshio [6 ]
Shimode, Katsuhiko [6 ]
Somiya, Kentaro [9 ]
Takeda, Hiroki [1 ]
Tomaru, Takayuki [8 ]
Uchiyama, Takashi [6 ]
Ushiba, Takafumi [2 ]
Yamamoto, Kazuhiro [10 ]
Yokozawa, Takaaki [11 ]
Yuzurihara, Hirotaka [11 ]
机构
[1] Univ Tokyo, Dept Phys, Tokyo 1130033, Japan
[2] Univ Tokyo, Inst Cosm Ray Res, Kashiwa, Chiba 2778582, Japan
[3] Natl Astron Observ Japan, Mitaka, Tokyo 1818588, Japan
[4] Grad Univ Adv Studies, SOKENDAI, Hayama, Kanagawa 2400193, Japan
[5] Univ Tokyo, Res Ctr Early Universe, Tokyo 1130033, Japan
[6] Univ Tokyo, KAGRA Observ, Inst Cosm Ray Res, Hida, Gifu 5061205, Japan
[7] Acad Sinica, Inst Phys, Taipei 11529, Taiwan
[8] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[9] Tokyo Inst Technol, Dept Phys, Ookayama, Meguro 1528550, Japan
[10] Univ Toyama, Dept Phys, Toyama, Toyama 9308555, Japan
[11] Osaka City Univ, Dept Phys, Sumiyoshi, Osaka 5588585, Japan
基金
新加坡国家研究基金会;
关键词
gravitational waves; cryogenic laser interferometer; vibration isolation; coil-magnet actuator; lock acquisition; SYSTEM;
D O I
10.1088/1361-6382/aa90e3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
KAGRA is a 3 km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Interferometer design of the KAGRA gravitational wave detector
    Aso, Yoichi
    Michimura, Yuta
    Somiya, Kentaro
    Ando, Masaki
    Miyakawa, Osamu
    Sekiguchi, Takanori
    Tatsumi, Daisuke
    Yamamoto, Hiroaki
    [J]. PHYSICAL REVIEW D, 2013, 88 (04):
  • [2] Sapphire mirror for the KAGRA gravitational wave detector
    Hirose, Eiichi
    Bajuk, Dan
    Billingsley, GariLynn
    Kajita, Takaaki
    Kestner, Bob
    Mio, Norikatsu
    Ohashi, Masatake
    Reichman, Bill
    Yamamoto, Hiroaki
    Zhang, Liyuan
    [J]. PHYSICAL REVIEW D, 2014, 89 (06):
  • [3] KAGRA, the underground and cryogenic laser interferometer for gravitational wave detection
    Kokeyama, Keiko
    [J]. 2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2020,
  • [4] Status of a cryogenic mirror suspension for KAGRA gravitational wave detector
    Ushiba, Takafumi
    [J]. 15TH MARCEL GROSSMANN MEETING, PT A, 2022, : 1606 - 1611
  • [5] Progress on the cryogenic system for the KAGRA cryogenic interferometric gravitational wave telescope
    Sakakibara, Yusuke
    Akutsu, Tomotada
    Chen, Dan
    Khalaidovski, Aleksandr
    Kimura, Nobuhiro
    Koike, Shigeaki
    Kume, Tatsuya
    Kuroda, Kazuaki
    Suzuki, Toshikazu
    Tokoku, Chihiro
    Yamamoto, Kazuhiro
    [J]. CLASSICAL AND QUANTUM GRAVITY, 2014, 31 (22)
  • [6] Safety management of an underground-based gravitational wave telescope: KAGRA
    Ohishi, Naoko
    Miyoki, Shinji
    Uchiyama, Takashi
    Miyakawa, Osamu
    Ohashi, Masatake
    [J]. OBSERVATORY OPERATIONS: STRATEGIES, PROCESSES, AND SYSTEMS V, 2014, 9149
  • [7] Structural design of primary mirror subassembly for spatial gravitational wave telescope
    Li, Yupeng
    Wang, Zhi
    Sha, Wei
    Wu, Qingwen
    Zhao, Ya
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2018, 47 (08):
  • [8] Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection
    Losurdo, G
    Calamai, G
    Cuoco, E
    Fabbroni, L
    Guidi, G
    Mazzoni, M
    Stanga, R
    Vetrano, F
    Holloway, L
    Passuello, D
    Ballardin, G
    Braccini, S
    Bradaschia, C
    Cavalieri, R
    Cecchi, R
    Cella, G
    Dattilo, V
    Di Virgilio, A
    Fidecaro, F
    Frasconi, F
    Gennai, A
    Giazotto, A
    Ferrante, I
    La Penna, P
    Lelli, F
    Lomtadze, T
    Marin, A
    Mancini, S
    Paoletti, F
    Pasqualetti, A
    Passaquieti, R
    Poggiani, R
    Taddei, R
    Vicerè, A
    Zhang, Z
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (09): : 3653 - 3661
  • [9] Large-scale cryogenic gravitational-wave telescope in Japan: KAGRA
    Akutsu, Tomotada
    [J]. 10TH INTERNATIONAL LISA SYMPOSIUM, 2015, 610
  • [10] Structural design optimization of space gravitational wave telescope primary mirror system
    Wang, Chenzhong
    Hu, Zhongwen
    Chen, Yi
    Xu, Mingming
    Chen, Lisi
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2020, 49 (07):