Combined thermal and natural ventilation modeling for long-term energy assessment: validation with experimental measurements

被引:26
|
作者
Koinakis, CJ [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Civil Engn, Lab Bldg Construct & Phys, GR-54006 Thessaloniki, Greece
关键词
ventilation; large openings; energy balance; energy efficiency;
D O I
10.1016/j.enbuild.2004.06.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The role of ventilation in the energy balance of buildings is very important, as well as the need to model the use of lame openings by occupants in energy simulation. Examples of detailed assessment of natural ventilation in overall building thermal simulation procedures are rather rare, especially for long-term evaluation and different types of ventilation. This study addresses this need focusing on natural ventilation modeling in building energy simulation and introducing coupled thermal and ventilation nodal modeling in 1 h simulation steps. All the related parameters are taken into consideration, from wind pressure data to building envelopes and user behavior. The results are validated by conducting experiments on existing constructions and the thermal behavior is monitored and compared in detail in specific building elements. Coupled thermal and ventilation modeling is then implemented to model and assess ventilation strategies for optimum energy-efficient ventilation in a common apartment. These strategies are compared and analyzed for mild Mediterranean and oceanic climates and optimum design procedures are proposed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 323
页数:13
相关论文
共 50 条
  • [1] LONG-TERM ASSESSMENT OF VENTILATION TUBES
    GIBB, AG
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1980, 94 (01): : 39 - 51
  • [2] MODELING NATURAL VENTILATION INDUCED BY COMBINED THERMAL BUOYANCY AND WIND
    ZHANG, JS
    JANNI, KA
    JACOBSON, LD
    TRANSACTIONS OF THE ASAE, 1989, 32 (06): : 2165 - 2174
  • [4] Long-term natural ice nuclei measurements
    Kim, NS
    Shkodkin, AV
    NUCLEATION AND ATMOSPHERIC AEROSOLS 1996, 1996, : 816 - 819
  • [5] Energy assessment of a roof-integrated phase change materials, long-term numerical analysis with experimental validation
    Elawady, Nahed
    Bekheit, Maher
    Sultan, Ahmed A.
    Radwan, Ali
    APPLIED THERMAL ENGINEERING, 2022, 202
  • [6] ASSESSMENT OF LONG-TERM MIDDLE-EAR VENTILATION
    ELIACHAR, I
    JOACHIMS, HZ
    GOLDSHER, M
    GOLZ, A
    ACTA OTO-LARYNGOLOGICA, 1983, 96 (1-2) : 105 - 112
  • [7] Validation of Long-term Measurements from FBG Sensors
    Abdel-Jaber, Hiba
    Glisic, Branko
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2016, 2016, 9805
  • [8] Systematic method for the validation of long-term temperature measurements
    Abdel-Jaber, H.
    Glisic, B.
    SMART MATERIALS AND STRUCTURES, 2016, 25 (12)
  • [9] Wind energy and natural ventilation potential of a wind catcher in Yazd - Iran (a long-term measurement)
    Hedayat, Zhaleh
    Belmans, Bert
    Ayatollahi, M. Hossein
    Wouters, Ine
    Descamps, Filip
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2017, 14 (07) : 650 - 655
  • [10] Modeling Long-Term Signature Validation for Resolution of Dispute
    Ben MBarka, Moez
    Krief, Francine
    Ly, Olivier