Systematic method for the validation of long-term temperature measurements

被引:18
|
作者
Abdel-Jaber, H. [1 ]
Glisic, B. [1 ]
机构
[1] Princeton Univ, Dept Civil & Environm Engn, Princeton, NJ 08544 USA
基金
美国国家科学基金会;
关键词
structural health monitoring; temperature validation; FBG sensors; long-term monitoring; temperature measurements; measurement drift; DAMAGE DETECTION; REGRESSION; BRIDGE; LINE;
D O I
10.1088/0964-1726/25/12/125025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Structural health monitoring (SHM) is the process of collecting and analyzing measurements of various structural and environmental parameters on a structure for the purpose of formulating conclusions on the performance and condition of the structure. Accurate long-term temperature data is critical for SHM applications as it is often used to compensate other measurements (e.g., strain), or to understand the thermal behavior of the structure. Despite the need for accurate long-term temperature data, there are currently no validation methods to ensure the accuracy of collected data. This paper researches and presents a novel method for the validation of long-term temperature measurements from any type of sensors. The method relies on modeling the dependence of temperature measurements inside a structure on the ambient temperature measurements collected from a reliable nearby weather tower. The model is then used to predict future measurements and assess whether or not future measurements conform to predictions. The paper presents both the model selection process, as well as the sensor malfunction detection process. To illustrate and validate the method, it is applied to data from a monitoring system installed on a real structure, Streicker Bridge on the Princeton University campus. Application of the method to data collected from about forty sensors over five years showed the potential of the method to categorize normal sensor function, as well as characterize sensor defect and minor drift.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Validation of a method for estimating long-term exposures based on short-term measurements
    Wallace, L
    Williams, R
    RISK ANALYSIS, 2005, 25 (03) : 687 - 694
  • [2] Validation of Long-term Measurements from FBG Sensors
    Abdel-Jaber, Hiba
    Glisic, Branko
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2016, 2016, 9805
  • [3] Long-Term Validation of Wave Height Measurements from Altimeters
    Queffeulou, Pierre
    MARINE GEODESY, 2004, 27 (3-4) : 495 - 510
  • [4] Study of the Categorisation Method Using Long-term Measurements
    Rey Gozalo, Guillermo
    Barrigon Morillas, Juan Miguel
    Gomez Escobar, Valentin
    Vilchez-Gomez, Rosendo
    Mendez Sierra, Juan Antonio
    Carmona del Rio, Francisco Javier
    Prieto Gajardo, Carlos
    ARCHIVES OF ACOUSTICS, 2013, 38 (03) : 397 - 405
  • [5] Validation of Long-Term Data from FBG Temperature Sensors
    Abdel-Jaber, Hiba
    Glisic, Branko
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 481 - 487
  • [6] Development of a DualEmission Laser-Induced Fluorescence (DELIF) Method for Long-Term Temperature Measurements
    Toriyama, Koji
    Funatani, Shumpei
    Tada, Shigeru
    SENSORS, 2024, 24 (22)
  • [7] Long-term temperature
    Anna Petherick
    Nature Climate Change, 2011, 1 (7) : 344 - 344
  • [8] METHOD FOR LONG-TERM GAS-EXCHANGE MEASUREMENTS BY MASK
    SNIDER, MT
    OERTER, KE
    RICHARD, RB
    ROBBINS, ME
    FRANCALANCIA, NA
    FEDERATION PROCEEDINGS, 1985, 44 (05) : 1581 - 1581
  • [9] A RAPID METHOD FOR DETERMINING LONG-TERM STRENGTH BY HARDNESS MEASUREMENTS
    ROKHLIN, IN
    INDUSTRIAL LABORATORY, 1960, 26 (07): : 910 - 912
  • [10] Recovery and validation of Odin/SMR long-term measurements of mesospheric carbon monoxide
    Grieco, Francesco
    Perot, Kristell
    Murtagh, Donal
    Eriksson, Patrick
    Forkman, Peter
    Rydberg, Bengt
    Funke, Bernd
    Walker, Kaley A.
    Pumphrey, Hugh C.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2020, 13 (09) : 5013 - 5031