The distribution of air temperature and velocity in the selected boiler room

被引:3
|
作者
Cichowicz, Robert [1 ]
Stelegowski, Artur [1 ]
机构
[1] Lodz Univ Technol, Fac Architecture Civil & Environm Engn, Al Politech 6, PL-90924 Lodz, Poland
关键词
THERMAL COMFORT; CFD;
D O I
10.1051/e3sconf/20184400020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The crucial impact on the indoor air quality in technological rooms, including boiler plant buildings, is made by operation of technological devices and ventilation systems. Therefore, the distribution of air temperature and velocity in these rooms mainly depends on location and heat gains generated by combustion devices, as well as emplacement of air supply and air exhaust elements. The temperature and airflow volume of supplied air is also an issue, because the indoor environment parameters are formed by the flow of air in the working area. Determination of the impact of physical factors on the thermal environment in a room is possible using an analysis of the air temperature and velocity. This issue is vital in terms of necessity to maintain the adequate heat conditions in the working area. Therefore, basing on the experimental measurements and numerical calculations (made in DesignBuilder software), the distribution of air temperature and velocity was analyzed in the selected industrial boiler room, located in the Lodz city, in Poland. The results obtained were compared with the recommended and limit values in the industrial buildings.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] 'Boiler Room'
    Wrathall, J
    [J]. SIGHT AND SOUND, 2000, 10 (06): : 36 - 37
  • [22] Velocity distribution in a room ventilated by displacement ventilation and wall-mounted air terminal devices
    Nielsen, PV
    [J]. ENERGY AND BUILDINGS, 2000, 31 (03) : 179 - 187
  • [23] Mechanics and air distribution in air chamber of grate-firing boiler
    Xu, Tong-mo
    Liu, Yao-qi
    Hui, Shi-en
    [J]. Dongli Gongcheng/Power Engineering, 1988, 8 (06): : 59 - 64
  • [24] Erosion behaviour of boiler component materials at room temperature and 400 °C temperature
    Singh, Prashant Kumar
    Mishra, S. B.
    [J]. MATERIALS RESEARCH EXPRESS, 2020, 7 (01):
  • [25] Influence of air distribution in the furnace on economical operation of the boiler
    Wu, Dong-Yin
    Wei, Xiao-Lin
    Sheng, Hong-Zhi
    Xu, Yong-Xiang
    Li, Hua-Min
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2005, 26 (01): : 163 - 166
  • [26] Research on Air Distribution Control Strategy of Supercritical Boiler
    Jin, Yingai
    Sun, Yanwei
    Zhang, Yuanbo
    Jiang, Zhipeng
    [J]. ENERGIES, 2023, 16 (01)
  • [27] TEMPERATURE DISTRIBUTION IN THE TUBES OF A WASTE HEAT BOILER
    GUDENAU, HW
    DAHL, W
    KOERFER, M
    SCHEIWE, M
    [J]. STEEL RESEARCH, 1990, 61 (04): : 157 - 163
  • [28] CALCULATION OF TEMPERATURE DISTRIBUTION IN A BOILER ELEMENT WITH DEFECTS
    MINASHIN, VE
    RUMYANTSEV, VN
    [J]. HIGH TEMPERATURE, 1974, 12 (05) : 921 - 925
  • [29] ROOM AIR DISTRIBUTION WITH A VARIABLE AIR VOLUME SYSTEM
    STRAUB, HE
    [J]. ASHRAE JOURNAL, 1969, 11 (06): : 69 - &
  • [30] Energy efficient room air distribution
    Awbi, HB